排序方式: 共有23条查询结果,搜索用时 234 毫秒
1.
2.
3.
本文以日立180-80原子吸收分光光度计为例进行了仪器精密度及总不确定度实验的初步探讨,同时作出了该仪器适用性的判断。 相似文献
4.
Antonio J. LaPorte Jack E. Feldner Jan C. Spies Tom J. Maher Prof. Martin D. Burke 《Angewandte Chemie (International ed. in English)》2023,62(40):e202309566
Multifunctional organoboron compounds increasingly enable the simple generation of complex, Csp3-rich small molecules. The ability of boron-containing functional groups to modify the reactivity of α-radicals has also enabled a myriad of chemical reactions. Boronic esters with vacant p-orbitals have a significant stabilizing effect on α-radicals due to delocalization of spin density into the empty orbital. The effect of coordinatively saturated derivatives, such as N-methyliminodiacetic acid (MIDA) boronates and counterparts, remains less clear. Herein, we demonstrate that coordinatively saturated MIDA and TIDA boronates stabilize secondary alkyl α-radicals via σB-N hyperconjugation in a manner that allows site-selective C−H bromination. DFT calculated radical stabilization energies and spin density maps as well as LED NMR kinetic analysis of photochemical bromination rates of different boronic esters further these findings. This work clarifies that the α-radical stabilizing effect of boronic esters does not only proceed via delocalization of radical character into vacant boron p-orbitals, but that hyperconjugation of tetrahedral boron-containing functional groups and their ligand electron delocalizing ability also play a critical role. These findings establish boron ligands as a useful dial for tuning reactivity at the α-carbon. 相似文献
5.
6.
介绍了中高能电子散射全截面绝对测量装置的设计,采用直线透射技术.因采用了恒温控制作用室,以便较准确测量反应室的绝对气压值;同时采用静电型圆柱能量分析器,并用计数率测量模式代替通常的束流强度测量模式,从而可以大幅度减小接收立体角,抑制零度角的弹性散射贡献.通过以上几项措施,可以有效地提高测量的精度,从而可以对一些有意义的分子的中、高能电子散射全截面进行绝对测量. 相似文献
7.
8.
D. Jacquemart L. Gomez N. Lacome J.-Y. Mandin O. Pirali P. Roy 《Journal of Quantitative Spectroscopy & Radiative Transfer》2010,111(9):1223-34
Absolute intensities of about 120 lines of the 12C2H2 molecule are reported for the ν4-ν5 band between 65 and 192 cm-1, with an average accuracy of 5%. Vibrational transition dipole moment squared values and empirical Herman-Wallis coefficients are obtained allowing modelling the rotational dependence of the transition dipole moment squared. Special care is taken to accurately determine an apparatus function for the Bruker IFS 125-HR coupled to the synchrotron SOLEIL far infrared AILES beamline in order to minimize its effects on the line parameter retrieval. 相似文献
9.
介绍了中高能电子散射全截面绝对测量装置的设计,采用直线透射技术.因采用了恒温控制作用室,以便较准确测量反应室的绝对气压值;同时采用静电型圆柱能量分析器,并用计数率测量模式代替通常的束流强度测量模式,从而可以大幅度减小接收立体角,抑制零度角的弹性散射贡献.通过以上几项措施,可以有效地提高测量的精度,从而可以对一些有意义的分子的中、高能电子散射全截面进行绝对测量. 相似文献
10.