首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   64篇
  免费   1篇
化学   64篇
物理学   1篇
  2021年   1篇
  2017年   1篇
  2016年   2篇
  2015年   2篇
  2014年   1篇
  2013年   4篇
  2012年   3篇
  2011年   6篇
  2010年   6篇
  2009年   4篇
  2008年   4篇
  2007年   6篇
  2005年   8篇
  2004年   4篇
  2003年   6篇
  2002年   2篇
  2001年   2篇
  2000年   2篇
  1998年   1篇
排序方式: 共有65条查询结果,搜索用时 31 毫秒
1.
Supercritical fluid chromatography (SFC) was used for the analysis of ethoxylated and propoxylated surfactants. Samples were derivatized to phenylated silyl ethers with a disilazane-chlorosilane mixture. Addition of a phenyl group to the surfactant allowed UV-absorbance detection of each oligomer. Acetonitrile and methanol were evaluated as mobile phase modifiers. Better peak shape was realized with methanol-modified CO2 on an octadecyl silica bonded phase than with acetonitrile-modified CO2. Peak assignments were made via SFC coupled with electrospray ionization-mass spectrometry (ESI-MS) in the positive ion mode. A sulfonamide-embedded alkyl stationary phase was also evaluated for separation of the derivatized samples. SFC-UV and SFC-ESI-MS data were jointly used for calculation of average molar oligomer values which were then compared to values calculated from 1H NMR data of non-derivatized samples. The derivatization or separation method using the sulfonamide embedded phase required no preliminary cleanup and yielded reproducible oligomer values that were consistent with those of the manufacturer's nominal values.  相似文献   
2.
Reversed-phase LC-MS/MS is used to determine major estrogenic alkylphenol ethoxylates (APEOs) and their biotransformation products. It allows the simultaneous analysis of eight APEOs, alkylphenoxy carboxylates (APECs) and alkylphenols (APs) in sewage treatment plant (STP) effluents in the same extract after solid-phase enrichment on polymeric Oasis HLB. As precursor ions, [APEO + NH4]+, [APEC - H]- and [AP - H]- were monitored. Instrumental limits of detection (LOD) were 2-600 pg, corresponding to sample concentrations of 0.04-12 ng l(-1), without correction for overall method recoveries. Matrix-induced signal suppression during electrospray ionisation (ESI) and extraction as well as overall method recoveries were assessed and the suitability of deuterated surrogates as internal standards was evaluated.  相似文献   
3.
Tan BL  Ali Mohd M 《Talanta》2003,61(3):385-391
A total of seven pesticides and eight alkylphenols were monitored using this method for the determination of their trace levels in human cord blood. The pesticides are lindane, diazinon, α-endosulfan, β-endosulfan, endosulfan sulfate, chlorpyrifos and endrin; while the alkylphenols are 4-n-butylphenol, 4-n-pentylphenol, 4-n-hexylphenol, 4-t-octylphenol, 4-n-heptylphenol, nonylphenol, 4-n-octylphenol and bisphenol A. The pesticides and alkylphenols in the cord blood samples were extracted with solid phase extraction IST C18 cartridges and analyzed by selected ion monitoring mode using quadrapole detector in Shimadzu QP-5000 gas chromatograph-mass spectrometer. Trace levels of pesticide and alkylphenols in the range of non-detectable to 15.17 ng ml−1, were detected in the human cord blood samples. This technique of monitoring the levels of endocrine-disruptors in blood samples is consistent, reliable and cost effective while reducing wastage of time and solvents.  相似文献   
4.
Summary Five different extraction techniques (Soxhlet, automated Randall, accelerated solvent extraction, microwave-assisted solvent extraction and extraction with a surfactant solution) have been evaluated for the determination of nonylphenol (NP) and nonylphenol ethoxylates (NPEO) in river sediments. All the techniques were applied to the same three samples collected from northern Italian rivers. The analyses were performed with two RP columns, with different stationary reversed phases—a classical C18 phase and a hexyl–phenyl phase. The recoveries and reproducibility of the different extraction techniques were comparable and all the methods gave reliable results. The variance of the results was dominated by the variance in sample homogeneity, sample preparation, and chromatographic analysis. A choice between the methods can be made on the basis of the cost and safety of each technique. Preliminary results obtained from use of a water-based extraction method with a surfactant solution (Tween-80), and its application to analysis of sediment and of worm tissue, are also presented.Presented at: Chemical Analysis and Risk Assessment of Emerging Contaminants, Barcelona, Spain, November 28–30, 2002  相似文献   
5.

A series of polyglycerol diisostearate ethoxylates with two hydrophobic chains were prepared by the reaction of polyglycerol diisostearate with ethylene oxide. Surface properties including water solubility, cloud temperature, critical micelle concentration, emulsification, and the solubilizing capacity of polyglycerol diisostearate ethoxylates for simvastatin were investigated in comparison with those of Tween‐80. The critical micelle concentrations of all polyglycerol diisostearate ethoxylates are less than 0.01 mmol l?1, which is one order of magnitude lower than that of Tween‐80. Polyglycerol diisostearate ethoxylates show better emulsification than Tween‐80. For enhancing the solubility of simvastatin in micelles, polyglycerol diisostearate ethoxylates also are superior to Tween‐80.  相似文献   
6.
Alcohol ethoxylates (AEs) are a significant component of a stream of surfactants directed to the aquatic environment. The aim of this work was the investigation of the dependence of the analytical signals of homogeneous AE homologues on liquid chromatography with tandem mass spectrometry conditions, as well as the separation of AEs from the water matrix and, on this basis, the development of an analytical procedure suitable for the determination of AEs in environmental samples. Homogeneous homologues containing dodecyl moiety and 2–9 oxyethylene subunits were investigated. The analytical signals of the investigated homologues were optimized in terms of concentration of ammonium acetate in the mobile phase (optimum 5 mM) and a column temperature (optimum 35°C) of the liquid chromatography with tandem mass spectrometry system. A separation of AEs from the water matrix by liquid–liquid extraction (ethyl acetate, chloroform) or solid‐phase extraction (C18, styrene divinylbenzene, H‐RX) was investigated. In a model investigation, the best recoveries (>90%) were obtained with a styrene divinylbenzene cartridge eluted with a 1:1 mixture of chloroform and methanol. However, much worse recoveries were obtained from the river water sample. Better results were obtained for liquid–liquid extraction with ethyl acetate. Recoveries of 62–80% were obtained for homologues having 4–9 oxyethylene subunits, at the lowest spike.  相似文献   
7.
固相萃取柱上衍生气相色谱-质谱法测定水中烷基酚   总被引:7,自引:0,他引:7  
以烷基酚(APs)主要降解产物辛基酚(4-t-OP)、壬基酚(4-n-NP)为研究对象,建立了固相萃取(SPE)柱上衍生化、气相色谱-质谱(GC-MS)法测定水中APs的分析方法。以C18柱为固相萃取柱、N,O-(三甲基硅)三氟乙酰胺(BSTFA)为硅烷化试剂,设计五因素四水平正交实验L16(45),对衍生化影响因素、衍生化溶剂、衍生化时间以及SPE主要影响因素pH值、盐度和洗脱剂进行优化;在优化条件下,方法的回收率(高于80%)和重现性(RSD低于10%)结果令人满意,4-t-OP和4-n-NP的仪器检出限分别为3.35ng/L和6.38ng/L。采用建立的方法,回收率略高于传统的SPE萃取衍生法,具有有机溶剂用量少,方法简单快速、灵敏度高的特点,适用于河水和海水中痕量烷基酚的快速测定。  相似文献   
8.
Liquid secondary ion (LSI) mass spectra of ion-pair precipitates obtained for Triton X-100 with strontium, lead, cadmium and mercury tetraphenylborates and for selected butoxylene-ethoxylene monoalkyl ethers with barium tetraiodobismuthate(III) are discussed. On the basis of LSI mass spectra, recorded in both positive and negative modes, the formulae of the ion-pair precipitates were determined. On the basis of B/E mass spectra, the fragmentation routes of [M - H + Ba](+) ions for butoxylene-ethoxylene monoalkyl ether complexes of barium and [M - H + Cd](+) ions for the Triton X-100 complex of cadmium are proposed.  相似文献   
9.
Dispersive liquid–liquid microextraction (DLLME) coupled with high-performance liquid chromatography with fluorescence detector was applied for the determination of alkylphenols and their short-chained ethoxylates in water samples. Development of DLLME procedure included optimisation of some important parameters such as kind and volume of extracting and dispersing solvents. Under optimised conditions 50 μL of trichloroethylene in 1.5 mL of acetone were rapidly injected into 5 mL of a water sample. After centrifuging the organic phase containing the analytes was taken for evaporation with a gentle nitrogen purge and reconstituted to 50 μL of acetonitrile. The aliquot of this solution was analysed with the use of HPLC. For octylphenol (OP) and octylphenol ethoxylates (OPEOs) linearity was satisfactory in the range 8–1000 μg L−1 and for nonylphenol (NP) and nonylphenol ethoxylates (NPEOs) linearity was in the range from 50 to about 3000 μg L−1. Limit of quantitation was 0.1 μg L−1 for OP and OPEOs and 0.3 μg L−1 for NP and NPEOs. Satisfactory recoveries between 66 and 79% were obtained for environmental samples. The results showed that DLLME is a simple, rapid and sensitive analytical method for the preconcentration of trace amounts of alkylphenols and their ethoxylates in environmental water samples.  相似文献   
10.
A new method for determining endocrine disrupter compounds (EDCs) in sewage sludge is described in this paper. EDCs studied were bisphenol A (BPA) and alkylphenols (APs). In order to obtain a fast and simple method, selective pressurised liquid extraction (SPLE) and focused ultrasound solid-liquid extraction (FUSLE) were tested. Best results for SPLE were obtained using Florisil as clean-up sorbent and dichloromethane as extraction solvent, while temperature was the only significant variable. Analyte extraction by SPLE was completed in only one extraction cycle of 1 min at 130 °C. FUSLE was carried out in one step of 20 s at 75% power (0.5 cycles) and with 8 mL of ethyl acetate. Although the optimised FUSLE process was faster, simpler and cheaper, SPLE provided higher recovery values (ranging from 81 to 105%) and therefore SPLE-based method was selected and validated. The SPLE and GC-MS method showed an LOD of 10.7 ng/g for BPA and LODs between 1.2 and 41.6 ng/g for APs. Relative standard deviation values lower than 6% were obtained for all analytes. As a result, an efficient, fast and simple method based on SPLE and GC-MS for the determination of BPA and APs in sewage sludge is proposed.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号