1.
The transmission-reflection method is modified for measuring constitutive parameters of thin high-loss materials used as radar absorbers. The method uses a two-layer structure, consisting of a layer of thin flexible unknown material supported by a thicker rigid known material. The analysis and measurements focus on nonmagnetic samples of a high dielectric constant and loss factor and on the waveguide configuration in the X-band. A nonlinear least-squares optimization is used to obtain the complex permittivity from the measured scattering parameters. The uncertainty analysis presented facilitates selection of the support layer thickness. Simulations with the finite-difference time-domain method explore the effects of sample imperfections. Accuracy of a few percent can be achieved for a sample thickness of a fraction of a millimeter, provided that the thickness of the support dielectric is close to optimum and sample has only small surface imperfections.  相似文献   
2.
Dielectric measurements using a rational function model   总被引:3,自引:0,他引:3  
A recently proposed rational function model for the aperture admittance of 50 ohm Teflon filled coaxial lines in contact with a homogeneous dielectric is experimentally validated. A calibration technique of the automatic network analyzer utilizing standard terminations and time domain gating is used. Uncertainties in the dielectric properties of reference liquids do not enter the calibration procedure. Experimental results for water and methanol are compared with estimated values. A model expression for the sensitivity of the probe is validated. The sensitivities of two coaxial line probes for the measurements made are determined. Results obtained using the new model are compared with those of other workers  相似文献   
3.
A simple extension to the staircase FDTD algorithm yielding accurate subcell models of flat metal walls and corners is presented. Electric field nodes on the edges of staircase models of perfect electric conductors are replaced by values obtained using interpolation or analytic continuation into the metal. The algorithm is validated by computing the resonant frequencies of cavities  相似文献   
4.
Human exposure to external 50/60-Hz electric and magnetic fields induces electric fields within the body. These induced fields can cause interference with implanted pacemakers. In the case of exposure to magnetic fields, the pacemaker leads are subject to induced electromotive forces, with current return paths being provided by the conducting body tissues. Modern computing resources used in conjunction with millimeter-scale human body conductivity models make numerical modeling a viable technique for examining any such interference. In this paper, an existing well-verified scalar-potential finite-difference frequency-domain code is modified to handle thin conducting wires embedded in the body. The effects of each wire can be included numerically by a simple modification to the existing code. Results are computed for two pacemaker lead insertion paths, terminating at either atrial or ventricular electrodes in the heart. Computations are performed for three orthogonal 60-Hz magnetic field orientations. Comparison with simplified estimates from Faraday's law applied directly to extracorporeal loops representing unipolar leads underscores problems associated with this simplified approach. Numerically estimated electromagnetic interference (EMI) levels under the worst case scenarios are about 40 microT for atrial electrodes, and 140 microT for ventricular electrodes. These methods could also be applied to studying EMI with other implanted devices such as cardiac defibrillators.  相似文献   
5.
The specific absorption rate (SAR) was measured in over 650 locations in a full-scale model of man exposed in the far and near field of antennas at 350 and 915 MHz. The whole-body average, the body-parts average, and the distributions of the SAR's are compared for three wave polarizations for the far and the near-field exposures. Effects on the energy deposition of the antenna type, gain, and location in the near field are discussed.  相似文献   
6.
Distributions of the specific absorption rate (SAR) were measured in a full-scale heterogeneous model of man. The model contained a skeleton, brain, lungs, and muscle. All these tissues had dielectric properties close to those of the respective in vivo properties of actual tissues at the test frequencies. SAR's were measured for exposures in the far field at 160, 350, and 915 MHz for the E and H polarizations. A computer-controlled scanning system and an implantable, minimally perturbing electric field probe were used. The results are also compared with the SAR distributions previously measured in a homogeneous model.  相似文献   
7.
Three-dimensional subgridding algorithm for FDTD   总被引:5,自引:0,他引:5  
In many computational problems solved using the finite-difference time-domain (FDTD) technique, there is a need to model selected volumes with higher resolution than the whole computational space. An efficient algorithm has been developed for this purpose that provides the mesh refinement by the factor of two in each direction. The algorithm can be used in two-dimensional (2-D) and three-dimensional (3-D) problems and provides for subgridding in both space and time. Performance of the 3-D algorithm was tested in waveguides and resonators. A high accuracy and efficiency were observed in all test cases with insignificant (of an order of -60 dB) reflections from mesh interfaces. Practical applications of the algorithm in the analyses of a resonator with a dielectric rod and of a cellular phone behavior in the vicinity of the operator head are also reported  相似文献   
8.
The pulse-receiving characteristics of resistively loaded dipoles are analyzed using a time-domain numerical technique. The Wu-King nonreflecting dipole and several other dipoles with higher and lower distributed resistances are considered. The time-domain responses of these dipoles to Gaussian electromagnetic pulses (incident in boresite direction) are calculated. Frequency-domain receiving transfer functions are obtained using the fast Fourier transform (FFT) technique. Dipoles terminated with high resistance loads are also considered. The effect of the distributed resistance and terminal resistance on the pulse response and bandwidth is discussed  相似文献   
9.
Energy Deposition in a Model of Man: Frequency Effects   总被引:1,自引:0,他引:1  
A computer-controlled scanning system and implantable, nonperturbing electric field probes were used to measure spatial distributions of the electric field in a full scale homogeneous model of a human body. The measurements were performed at three frequencies (160, 350, and 915 MHz) in the far-field and in the near-field of resonant dipoles. The specific absorption rate (SAR) distributions and the averages for body parts and the whole body are analyzed as functions of frequency. In the far-field, the SAR decreases exponentially in the direction of wave propagation in the torso at all frequencies, and large gradients of the SAR are observed along the body main axis, particularly for the E polarization. At 160 and 350 MHz high local SAR's are produced in the neck. It appears that for plane wave exposures the ratio of the peak SAR to the whole-body average SAR does not exceed 20. In the near-field, large SAR gradients are also produced, and the ratios of the peak spatial SAR to the whole-body average SAR vary from about 30 to 250 depending on the frequency and polarization. It is suggested that for near-field exposures the whole-body average SAR is not a proper dosimetric measure, and the SAR averaged over any 0.1 of the tissue volume is recommended instead.  相似文献   
10.
Dielectric properties of the inflated and deflated fceline lung in vivo were investigated at frequencies from 10 kHz to 100 MHz. A computer-controlled network analyzer and a multiring capacitive sensor were employed. It was found that in the frequency range investigated, both the dielectric constant and the conductivity of the deflated lung were higher than those of the inflated one. The analysis of the experimental data was performed using two approaches: the loss-tangent method and the curve-fitting computer program called STEPIT. It was found that in the middle band of frequencies for both inflated and deflated states of the lung, the dielectric response mainly reflects the membrane polarization of the capillary erythrocytes with possible contributions of other components, e.g., the pulmonary microphages. The dielectric relaxation time for the capillary erythrocytes in the lung is similar to that for the packed cells, which is much longer than for the erythrocytes at physiological concentrations. The dielectric parameters at low frequencies obtained using the STEPIT program differ significantly between the inflated and deflated lung. The observed dielectric data reflect at least two overlapping dispersions: of lung capillary erythrocytes and of cellular structures forming the alveoli.  相似文献   