排序方式: 共有111条查询结果,搜索用时 15 毫秒
1.
2.
I. Paradela Pérez M. Groth M. Wischmeier D. Coster D. Brida P. David D. Silvagni M. Faitsch the ASDEX-Upgrade Team the EUROfusion MST Team 《等离子体物理论文集》2020,60(5-6):e201900166
SOLPS-ITER L-mode-like simulations with the full set of currents and drift velocities activated, and fluid neutrals have been carried out to interpret experimental results obtained in AUG. Drifts are critical to quantitatively reproduce the experimental results; however, simulations without drifts can also reproduce some trends qualitatively. The magnitude and dependence of the peak heat flux onto both targets on the upstream collisionality are, in general, in quantitative agreement within uncertainties with infrared thermography measurements in favourable field direction. The onset of power detachment is observed. In unfavourable toroidal field direction, a more symmetrical inner/outer target solution with regards to the power distribution is predicted, in agreement with experimental observations. However, also in unfavourable toroidal field direction, insufficient power is dissipated in the simulations and therefore qpeak, inn is overpredicted by up to a factor of 4 and qpeak, out by up to a factor of 1.5. The largest contribution to the sources due to radial transport in the energy balance equation is the radial divergence of the energy flux due to VE × B. 相似文献
3.
重点介绍了 HL-2M 装置的运行技术和初步的等离子体控制实验结果,包括等离子体放电方案设计、
线圈电流控制、击穿阶段零场匹配和等离子体电流以及位移的控制。为了降低放电运行风险,HL-2M 装置初始放
电采用了简化的放电方案,通过整定 PID 参数实现了线圈电流控制,在击穿阶段获得了 10V 以上的环电压和较大
范围的零场区域,成功实现等离子体击穿。最后,投入了等离子体电流和水平位移反馈控制算法,成功将等离子
体放电脉宽提升至 200ms 以上,且维持 Ip≥100kA 的时间超过了 100ms,上述结果表明 HL-2M 装置运行控制技术
得到了初步的检验。 相似文献
4.
介绍了 HL-2M 装置冷却水系统的组成以及各子系统的循环流程、运行原理和运行参数。 相似文献
5.
Donné AJ van Gorkom JC Udintsev VS Domier CW Krämer-Flecken A Luhmann NC Schüller FC;TEXTOR Team 《Physical review letters》2005,94(8):085001
Small-scale structures with high poloidal mode numbers (m=10-20) have been observed in the TEXTOR tokamak plasma with pulsed radar reflectometry and an electron cyclotron emission diagnostic, in conjunction with large 2/1 and 1/1 islands. The small islands have a peaked density profile, similar to that of the simultaneously observed large-scale 2/1 islands. This together with the observation that high-frequency density and temperature fluctuations are very pronounced near the X points of the large islands hints to a strongly perturbed magnetic topology around the X points. 相似文献
6.
Liang Y Koslowski HR Kelly FA Tokar MZ Loozen X Bertschinger G Biel W Finken KH Jakubowski MW Krämer-Flecken A Zimmermann O Lehnen M Sergienko G Wolf RC;TEXTOR Team 《Physical review letters》2005,94(10):105003
A significant influence of the dynamic ergodic divertor (DED) on the density limit in TEXTOR has been found. In Ohmic discharges, where without DED detachment normally arises at the density limit, a MARFE (multifaceted asymmetric radiation from the edge) develops when the DED is operated in a static regime. The threshold of the MARFE onset in the neutral beam heated plasmas is increased by applying 1 kHz ac DED at the high-field side. The theoretical predictions based on the parallel energy balance taking poloidal asymmetries into account agree well with the experimental observation. 相似文献
7.
为提高磁体系统安装精度,在 HL-2M 集成大厅建立 63 个基准点构成测量基准网,并利用激光跟
踪仪等高精度测量设备建立每个磁体的局部坐标系,测量特征点的局部坐标;基于测量基准网和公共测量点,采
用最佳拟合得到坐标转换矩阵,以此得到特征点在测量基准网的位置,指导磁体安装。完成安装后的中心柱同支
撑基础的同轴度为∅2.03mm;PF1~PF4 线圈安装标高偏差为±0.5mm,与中心柱的同轴度为∅2.60mm;PF5/6/7/8
线圈与中心柱的同轴度偏差小于∅3.00mm,标高偏差在[−1mm, 1mm]区间内。基于以上方法所得到的线圈安装精
度都满足设计需求。 相似文献
8.
9.
为了测量 HL-2M 装置中的电子温度剖面分布,研制了一套扫频电子回旋辐射(SECE)系统。该系统
能够测量装置中心纵场大小在 1.4~2.2T 时的等离子体电子温度。采用扫频外差接收的方式,径向空间分辨达到
2.5cm,时间分辨达到 1ms。接收机前端的准光学系统采用两级金属反射镜的配置,系统能够接收的最小极向光
斑的直径为 1.5cm(波数 kθ<4.2rad·cm-1)。系统的频带范围覆盖 33~110GHz,采用 VCO 作为本振源,双边带混频
输出中频信号。后端首次采用高性能对数检波器解调中频,能直接对-70dBm 的微弱信号进行检测,输入-输出工
作区间的动态范围达到 45dB 以上。在实验期间,成功测量到了等离子体中电子逃逸以及回旋辐射产生的信号。 相似文献
10.
通过数值计算评估了 HL-2M 装置磁测量传感器安装精度的要求,其中磁通环坐标(R, Z)的安装偏差
要求达到±2.0mm 以内,磁探针的(R, Z)偏差要求在±1.0mm 以内、角度偏差在±0.1°以内。定位安装采用高精度激
光跟踪仪和关节测量臂结合,设备定位精度在±0.3mm。根据不同种类的磁测量传感器的定位安装特点,优化设
计了包括磁通环、磁探针阵列、逆磁同心圆等的定位结构,将 HL-2M 磁测量传感器的安装精度控制到在±0.5mm
水平。 相似文献