首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   20篇
  免费   0篇
化学   12篇
数学   2篇
物理学   6篇
  2021年   1篇
  2013年   2篇
  2012年   5篇
  2010年   1篇
  2007年   1篇
  2006年   1篇
  2005年   2篇
  2004年   1篇
  2000年   2篇
  1999年   1篇
  1990年   1篇
  1984年   1篇
  1974年   1篇
排序方式: 共有20条查询结果,搜索用时 15 毫秒
1.
The time delay experiment proposed by I.I. Shapiro in 1964 and conducted in the seventies was the most precise experiment of general relativity until that time. Further experimentation has improved the accuracy level of both the time delay and the light deflection experiments. A simulation model is proposed that involves only a simple mass and time transformation factor involving velocity of light. The light deflection and the time delay experiments are numerically simulated using this model that does not use the general relativistic equations. The computed values presented in this paper compare well with recent levels of accuracy of their respective experimental results.  相似文献   
2.
The first part of the paper deals with the requirements of the process industries for measurement transducers and systems. It classifies the industries and discusses the measurands involved. Reference is made to the desirable characteristics and performances of transducers as discrete units and as system components.The second half of the paper examines these requirements in relation to the potential of optical transducers. It concludes that although these new transducers could have some useful characteristics involving simplicity, safety and freedom from interference, there are many obvious design and development problems and limitations which have to be overcome before optical transducers can replace their electrical counterparts particularly in control systems.  相似文献   
3.
We present two new variants of Schur complement domain decompositionpreconditioners suitable for 2D anisotropic problems. Thesevariants are based on adaptations of the probing idea, describedby Chan et al (1992 Fifth Int. Symp. on Domain DecompositionMethods for Partial Differential Equations, Philadelphia: SIAM,pp 236-249), used in conjunction with a coarse grid approximationas introduced by Bramble et al (1986 Math. Comput. 47, 103-134).The new methods are specifically designed for situations wherethe coupling between neighbouring interfaces is stronger thanthe coupling within an interface. Taking into account this strongcoupling, one variant uses a multicolour probing technique toavoid distortion in the probe approximations that appear whenusing the method proposed by Chan et al. The second techniqueuses additional probe matrices to approximate not only the couplingwithin the interfaces but also the coupling between interfacepoints across the subdomains. This latter procedure looks somewhatlike an alternating line relaxation method for anisotropic problems,see Brandt (1977 Math. Comput.. 31, 333-390). To assess therelevance of the new preconditioners, we compare their numericalbehaviour with well known robust preconditioners such as thebalanced Neumann-Neumann method proposed by Mandel (1993 Commun.Numer. Methods Eng.. 9, 233-241).  相似文献   
4.
Singh  RS 《数学理论与应用》2000,20(1):128-128
(《马氏决策过程》,侯振挺、郭先平著,长沙,湖南科技出版社,1997,中文版,386页,定价:28元)马尔可夫决策过程是概率论的运筹学的理论研究和实际应用中极其重要的领域之一.随着中国和国际上对马尔可夫决策过程(MarkovDecisionProcesses,简记为MDP)研究的新进展,许  相似文献   
5.
The ‘anomalous perihelion precession’ of Mercury, announced by Le Verrier in 1859, was a highly controversial topic for more than half a century and invoked many alternative theories until 1916, when Einstein presented his theory of general relativity as an alternative theory of gravitation and showed perihelion precession to be one of its potential manifestations. As perihelion precession was a directly derived result of the full General Theory and not just the Equivalence Principle, Einstein viewed it as the most critical test of his theory. This paper presents the computed value of the anomalous perihelion precession of Mercury's orbit using a new relativistic simulation model that employs a simple transformation factor for mass and time, proposed in an earlier paper. This computed value compares well with the prediction of general relativity and is, also, in complete agreement with the observed value within its range of uncertainty. No general relativistic equations have been used for computing the results presented in this paper.  相似文献   
6.
Conventional electrochemical methods of determining the pH of body fluids have drawbacks. Newer optical methods offer the promise of miniaturisation and continuous in vivo measurements without drift. This report examines the ability of a holographic sensor based on a thin-film, biocompatible hydrogel (approximately 10 μm) of poly(2-hydroxyethyl methacrylate) and ionisable 2-(dimethylaminoethyl) methacrylate to accurately measure the pH of blood plasma ex vivo. It is found that the sensors behave in a fully reversible manner. After an initial calibration with buffers, they can measure pH over extended periods (more than 40 h). Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   
7.
High-performance thin-layer chromatography (HPTLC) was applied to the separation and quantification of aflatoxin in 300 jars of "crunchy" peanut butter. A critical evaluation of the proposed HPTLC method has been carried out by statistical comparisons with a commercially available enzyme-linked immunosorbent assay (ELISA) kit and a high-performance liquid chromatographic (HPLC) method. The statistical tests indicated that whilst the distributions of the data sets obtained with each method were similar, the HPLC method was found to be biased. Over-all results indicated that the HPTLC method gave more consistent data, relatively lower standard deviations and lower coefficients of variation. The ELISA kit was found to be less precise than the HPTLC and HPLC methods and prone to some loss of sensitivity caused by matrix interference.  相似文献   
8.
A sensitive and reliable high‐performance liquid chromatography–mass spectrometry (LC–MS/MS) was developed and validated for simultaneous quantification IC87114, roflumilast (RFM), and its active metabolite roflumilast N‐oxide (RFN) using tolbutamide as an internal standard. The analytes were extracted by using liquid–liquid extraction and separated on a reverse phase C18 column (50 mm × 3 mm i.d., 4.6 µ) using methanol: 2 mM ammonium acetate buffer, pH 4.0 as mobile phase at a flow rate 1 mL/min in gradient mode. Selective reaction monitoring was performed using the transitions m/z 398.3 > 145.9, 403.1 >186.9, 419.1 > 187.0 and 271.1 > 155.0 to quantify quantification IC87114, RFM, RFN and tolbutamide, respectively. The method was validated over the concentration range of 0.1–60 ng.mL?1 for RFM and RFN and 6 to 2980 ng.mL?1 for IC87114. Intra‐ and inter‐day accuracy and precision of validated method were within the acceptable limits of <15% at all concentrations. Coefficients of correlation (r2) for the calibration curves were >0.99 for all analytes. The quantitation method was successfully applied for simultaneous estimation of IC87114, RFM and RFN in a pharmacokinetic drug–drug interaction study in Wistar rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   
9.
This is the report of Heavy Ion Physics and Quark-Gluon Plasma at WHEPP-09 which was part of Working Group-4. Discussion and work on some aspects of quark-gluon plasma believed to have created in heavy-ion collisions and in early Universe are reported.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号