首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   20篇
  免费   0篇
化学   10篇
物理学   10篇
  2019年   1篇
  2013年   1篇
  2012年   1篇
  2011年   3篇
  2010年   2篇
  2008年   1篇
  2007年   1篇
  2006年   2篇
  2004年   1篇
  2002年   1篇
  1999年   1篇
  1990年   1篇
  1989年   1篇
  1988年   2篇
  1903年   1篇
排序方式: 共有20条查询结果,搜索用时 15 毫秒
1.
It is well known that laser scattered-light applicators when applied for laser-induced tumor therapy allow the precise thermal destruction of metastases. Using laser radiation in the NIR spectral range (usually, Nd:YAG laser systems λ = 1064 nm), a penetration depth of 5–10 cm (1/e is the decrease in radiation intensity) is achieved in biological tissues. The major tissue-optical parameters, i.e., absorption coefficient μa, scattering coefficient μs, and the anisotropy factor g, show biological tissues to be strongly scattering media which have a so-called optical window in the NIR. As a consequence, the therapeutic laser radiation is scattered and absorbed at a deeper level, leading to a virtual enlargement of the laser applicator. The thermal sclerotization and the thermal cell damage originate within the absorbing volume of the laser radiation and spread outward by thermal diffusion. There are three dosimetrically relevant zones of thermal and biological damage: (1) a zone of thermal coagulation; (2) a threshold of partial necrosis (destruction of all metabolic processes in the cell is the maintenance of essential parts of the cytoskeleton and the plasma membrane); this is characterized by a specific temperature range, the so-called phase transition, which refers to the transition from the gel phase of the biomembrane to the fluid phase; the determination of this temperature zone is an integral part of the following experimental investigations on MX1 cells; (3) an external zone of thermal effects made up of partial and multiple damage with a statistical chance of survival. This paper describes the investigations on heat stress in cancer cells to verify the maximum phase transition of the outer MX1 cell membranes and the related results. For this purpose, a novel method of quantum dot fluorescence dosimetry was developed. The evaluation of the measured laser-induced fluorescences yields a first approximation of the determination of the phase transition on MX1 cells.  相似文献   
2.
We report on the fabrication and performances of a solid-phase microextraction (SPME) fiber based on a stainless steel wire coated with a covalently attached polyacrylonitrile (PAN)/multi-walled carbon nanotubes (MWCNTs) composite. This new coating is obtained by atom transfer radical polymerization (ATRP) of acrylonitrile mixed with MWCNTs. ATRP is initiated from 11-(2-bromo-2-methylpropionyloxy)-undecyl-phosphonic acid molecules grafted on the wire surface via the phosphonic acid group. The extraction performances of the fibers are assessed on different classes of compounds (polar, non-polar, aromatic, etc.) from water solutions by headspace extraction. The optimization of the parameters affecting the extraction efficiency of the target compounds was studied as well as the reproducibility and the repeatability of the fiber. The fibers sustain more than 200 extractions during which they remain chemically stable and maintain good performances (detection limits lower than 2 μg/l, repeatability, etc.). Considering their robustness together with their easy and inexpensive fabrication, these fibers could constitute promising alternatives to existing products.  相似文献   
3.
Laser-induced autofluorescences show a strong intensity distortion for endogenous NADH in the UV and synthesized markers in the NIR range because of tissue optics. Rescaling taking into account bio-optical methods results in the chromophore profile in the observed tissue region. For the in vivo tests an experimental NIR imager was used. NIR fluorescence of the entire body of small animals can be imaged. For first experiments an undifferentiated superficial tumor of mouse thigh was used. Corrections that are due to tissue optics must take care of a more strongly scattering of the light in the NIR range in comparison to the UV fluorescence such as in optical biopsy. For example, the diameter of the fluorescent volume is apparently larger for the same reason. Therefore, the established rescaling from the UV adapted to the NIR range is important for the interpretation fluorescence pictures in biomedicine.  相似文献   
4.
5.
Cytidine 5′‐triphosphate synthetase (CTPS) is known to be a central enzyme in the de novo synthesis of CTP. We have recently demonstrated that a deficiency in CTPS1 is associated with an impaired capacity of activated lymphocytes to proliferate leading to a combined immunodeficiency disease. In order to better document its role in immunomodulation, we developed a method for measuring CTPS activity in human lymphocytes. Using liquid chromatography‐mass spectrometry, we quantified CTPS activity by measuring CTP in cell lysates. A stable isotope analog of CTP served as internal standard. We characterized the kinetic parameters Vmax and Km of CTPS and verified that an inhibition of the enzyme activity was induced after 3‐deazauridine (3DAU) treatment, a known inhibitor of CTPS. We then determined CTPS activity in healthy volunteers, in a family whose child displayed a homozygous mutation in CTPS1 gene and in patients who had developed or not a chronic lung allograft dysfunction (CLAD) after lung transplantation. Linearity of the CTP determination was observed up to 451 μmol/L, with accuracy in the 15% tolerance range. Michaelis‐Menten kinetics for lysates of resting cells were Km=280±310 μmol/L for UTP, Vmax=83±20 pmol/min and, for lysates of activated PBMCs, Km=230±280 μmol/L for UTP, Vmax=379±90 pmol/min. Treatment by 3DAU and homozygous mutation in CTPS1 gene abolished the induction of CTPS activity associated with cell stimulation, and CTPS activity was significantly reduced in the patients who developed CLAD. We conclude that this test is suitable to reveal the involvement of CTPS alteration in immunodeficiency.  相似文献   
6.
In this study, a method was developed for determination of steroid hormones (17beta-estradiol, estrone, 17alpha-ethynylestradiol) in tap and sewage water samples from Sweden. Sample preparation and analysis were performed by a hollow-fibre microporous membrane liquid-liquid extraction (HF-MMLLE) set-up combined with gas chromatography-mass spectrometry (GC-MS). In this approach, only the organic liquid in the lumen (10microL) of the hollow-fibre membrane was utilised for depleting extraction. Several parameters were studied, including: type of organic solvent, sample pH, salt and humic acid content. The optimised method allowed the determination of the analyte at the low ngL(-1) level in tap and sewage water. A linear plot gave correlation coefficients better than 0.995 and resulted in a method limit of detection of 1.6, 3 and 10ngL(-1) for 17beta-estradiol, estrone, and 17alpha-ethynylestradiol, respectively, in sewage water. Enrichment factors were over 1400 after derivatisation. The repeatabilities at 50 and 600ngL(-1) were better than 10% and 6%, respectively.  相似文献   
7.
With the Fréjus detector we studied four astrophysical point-like sources by using \(v_e (\bar v_e )\) and \(v_\mu (\bar v_\mu )\) interactions in the detector and \(v_\mu (\bar v_\mu )\) interactions in the surrounding rock. No excess of events was found. Therefore upper limits of neutrino fluxes and source luminositics are quoted. These limits confirm results from other experiments. In addition new limits are presented for spectral indices above 3.  相似文献   
8.
9.
Fast, selective, and sensitive analysis of inorganic anions is compulsory for the identification of explosives in post-blast or environmental samples. For the last twenty years, capillary electrophoresis (CE) has become a valuable alternative to ion chromatography (IC) for the analysis of inorganic-based explosives because of its low running costs and its simplicity of use. This article focuses on the development and validation of a CE method for the simultaneous analysis of 10 anions (chloride, nitrite, nitrate, thiosulphate, perchlorate, chlorate, thiocyanate, carbonate, sulphate, and phosphate) which can be found in post-blast residues, plus for the first time azide anion, possibly present in the composition of detonators, and the internal standard (formate) in 20 min total runtime. Intermediate precisions were 2.11% for normalized areas and 0.72% for normalized migration times. Limits of detection close to 0.5 ppm for all anions were obtained with the use of preconcentration techniques, thanks to a fast and simple sample preparation allowing the analysis of a large variety of matrices with the developed generic CE method. The matrix effects were statistically studied for the first time in the explosive field for different matrices, containing interfering anions and cations, sometimes at high levels. In fact, no significant matrix effect occurred (tests with blank matrix extracts of soil, cloth, glass, plastic, paper, cotton, and metal). Finally, analyses of real post-blast residues and real detonator extracts were performed. The CE results were compared with those obtained with the IC method used routinely and showed excellent correlation.  相似文献   
10.
Sander  M.  Minet  O.  Zabarylo  U.  Müller  M.  Tetz  M. R. 《Laser Physics》2012,22(4):805-812
The femtosecond-laser in situ keratomileusis procedure affords the opportunity to correct ametropia by cutting transparent corneal tissue with ultra-short laser pulses. Thereby the tissue cut is generated by a laser-induced optical breakdown in the cornea with ultra-short laser pulses in the near-infrared range. Compared to standard procedures such as photorefractive keratectomy and laser in-situ keratomileusis with the excimer laser, where the risk potential for the eye is low due to the complete absorption of ultraviolet irradiation from corneal tissue, only a certain amount of the pulse energy is deposited in the cornea during the fs-LASIK process. The remaining energy propagates through the eye and interacts with the retina and the strong absorbing tissue layers behind. The objective of the presented study was to determine and compare the retina damage thresholds during the fs-LASIK process simulated with two various laser systems in the CW- and fs-regime.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号