排序方式: 共有38条查询结果,搜索用时 15 毫秒
1.
Žydrė Šaltienė Natalija Jatulienė Mudis Šalkauskas Daiva Brukštienė Asta Ruzgytė Aušra Tarasevičiūtė Julius Kalibatas 《Accreditation and quality assurance》2005,10(8):444-451
The estimation scheme of uncertainty of determination of 1-hydroxypyrene (1-OHP) in urine was developed analysing the main
stages of the analytical procedure: (1) preparation of 1-OHP standards, (2) creation of the calibration curve for the high
performance liquid chromatography (HPLC) analysis method with the evaluation of recovery, (3) measuring procedure of aliquot
of urine, (4) adjusting the pH of aliquot and hydrolysis with enzyme, (5) solid phase extraction, (6) concentration of the
extract, (7) injection of the extract to chromatograph and analysing by the HPLC method, (8) calculation of 1-OHP mass from
the calibration curve, (9) calculation of 1-OHP concentration in urine. The evaluation of the uncertainty is based on quantification
of individual components. Combined uncertainty was calculated using the law of propagation of uncertainties according to the
EURACHEM/CITAC guidelines. Level dependence of the uncertainty arises from the calibration curve.
The limits of detection and quantification were found to be equal to 0.03 and 0.1 ng/mL, respectively. The calculated expanded
level-dependent uncertainty covers 47–27–25% within the concentration range 0.03–0.1–0.4 ng/mL with the materials and equipment
used. These parameters could easily be recalculated according to the proposed scheme if there are some changes in the analysis
procedure. 相似文献
2.
Ljubinka Lorenc Lidija Bondarenko-Gheorghiu Natalija Krsti Hermann Fuhrer Jaroslav Kalvoda Mihailo Lj. Mihailovi 《Helvetica chimica acta》1995,78(4):891-898
Upon heating in AcOH, the stereoisomeric (Z)- and (R)-6,9-dioxocyclodex-3-enyl derivatives, 5 and 6 , respectively, obtained by HgO/I2 oxidation of 5-hydroxy-8-oxo-8,14-seco-5α-androstane-3β,17β-diyl diacetate ( 3 ), undergo an unusual intramolecular rearrangement to give the corresponding unsaturated (5R,9R)- and (5R,9S)-spiro-lactones 7 and 8 , respectively. Hydroxylation of the C?C bond in 7 and 8 , and subsequent glycol cleavage of the resulting diols 9 and 10 afforded the epimeric spiro-lactones (5R,9S)- 11 and (5R,9R)- 14 , respectively, and in both cases, the ring-D-containing fragments 12 and 13 . 相似文献
3.
Natalija Vitezić Marjo Merslavić Miha Japelj 《Phosphorus, sulfur, and silicon and the related elements》2013,188(1-2)
Abstract The synthesis of new derivatives of thiazolidine 2-alkylidene-4-on-5-acetamidocephalosporanic acids or thiazolidine 2-arylidenazino-4-on-5-acetamidocephalosporanic acids and their salts of general formula (I) has been achieved. 相似文献
4.
Annija Lace Aideen Byrne Simon Bluett Laurent Malaquin Vincent Raimbault Remi Courson Zain Hayat Breda Moore Eoin Murray 《Journal of separation science》2022,45(5):1042-1050
An ion chromatography system employing a low-cost three-dimensional printed absorbance detector for indirect ultraviolet detection towards portable phosphate analysis of environmental and industrial waters has been developed. The optical detection cell was fabricated using stereolithography three-dimensional printing of nanocomposite material. Chromatographic analysis and detection of phosphate were carried out using a CS5A 4 × 250 mm analytical column with indirect ultraviolet detection using a 255 nm light-emitting diode. Isocratic elution using a 0.6 mM potassium phthalate eluent combined with 1.44 mM sodium bicarbonate was employed at a flow rate of 0.75 mL/min. A linear calibration range of 0.5 to 30 mg/L PO43− applicable to environmental and wastewater analysis was achieved. For retention time and peak area repeatability, relative standard deviation values were 0.68 and 4.09%, respectively. Environmental and wastewater samples were analyzed with the optimized ion chromatography platform and the results were compared to values obtained by an accredited ion chromatograph. For the analysis of environmental samples, relative errors of <14 % were achieved. Recovery analysis was also carried out on both freshwater and wastewater samples and recovery results were within the acceptable range for water analysis using standard ion chromatography methods. 相似文献
5.
Oligomeric intermediates on the pathway of amyloid fibrillation are suspected as the main cytotoxins responsible for amyloid-related pathogenicity. As they appear to be a part of the lag phase of amyloid fibrillation when analyzed using standard methods such as Thioflavin T (ThT) fluorescence, a more sensitive method is needed for their detection. Here we apply Fourier transform infrared spectroscopy (FTIR) in attenuated total reflectance (ATR) mode for fast and cheap analysis of destabilized hen-egg-white lysozyme solution and detection of oligomer intermediates of amyloid fibrillation. Standard methods of protein aggregation analysis— Thioflavin T (ThT) fluorescence, atomic force microscopy (AFM), and 8-anilinonaphthalene-1-sulphonic acid (ANS) fluorescence were applied and compared to FTIR spectroscopy data. Results show the great potential of FTIR for both, qualitative and quantitative monitoring of oligomer formation based on the secondary structure changes. While oligomer intermediates do not induce significant changes in ThT fluorescence, their secondary structure changes were very prominent. Normalization of specific Amide I region peak intensities by using Amide II peak intensity as an internal standard provides an opportunity to use FTIR spectroscopy for both qualitative and quantitative analysis of biological samples and detection of potentially toxic oligomers, as well as for screening of efficiency of fibrillation procedures. 相似文献
6.
Mira S. Bjelaković Natalija M. Krstić Dragana R. Milić Tatjana J. Kop Koen Robeyns Vladimir D. Pavlović 《Tetrahedron》2012,68(36):7479-7488
The present study is concerned with the oxidative behaviour of unsaturated and epoxy 5-oxo-5,10-secosteroids in the presence of m-CPBA or TFAA-UHP as oxidants in order to investigate potential parameters controlling the chemoselectivity and regioselectivity. In the study we discovered a striking difference in the chemical behaviour of stereoisomeric compounds, (Z)- and (E)-3β-acetoxy-5,10-secocholest-1(10)-en-5-ones, as well as 1S,10R- and 1R,10R-epoxides. The secoketones were oxidized with exclusively C-6 migration and Baeyer–Villiger rearrangement product formation, whereas their stereoisomers provided the ring-contracted products, without lactone formation. The preferred conformation of expanded and contracted rings was established by NOESY correlations. The structures of two obtained lactones were also confirmed by X-ray analysis. The mechanistic and stereochemical aspects of these transformations are discussed. 相似文献
7.
Elena M. Kirilova Inta Kalnina Tija Zvagule Natalija Gabruseva Natalja Kurjane Irina I. Solomenikova 《Journal of fluorescence》2011,21(3):923-927
The use of hydrophobic fluorescent probe ABM (benzanthrone derivative) and albumin autofluorescence allowed show conformational
alterations in Chernobyl clean-up workers blood plasma. Results obtained in 1996–1997 suggest that acidic expansion of plasma
albumin takes place. Latest data (2006–2008) result in splitting of albumin alterations onto two stages - acidic expansion
and N-F transition. The N-F transition is accompanied by the blue shift of fluorescence spectra and dehydration of tryptophanyl
region of albumin molecule. In 2007 obtained.patterns of ABM spectra had never been previously seen in examined healthy individuals
or patients with tuberculosis, multiple sclerosis, rheumatoid arthritis, etc. Patterns of ABM fluorescence spectra are associated
with conformational changes of blood plasma albumin. The use of probe ABM and albumin auto-fluorescence allowed show conformational
alterations in albumin of Chernobyl clean-up workers blood plasma. It is necessary to note that all investigated parameters
significantly differ in observed groups of patients. These findings reinforce our understanding that the blood plasma albumin
is a significant biological target of radiation. It may be concluded that fluorescence characteristics are representative
of radiation induced albumin alterations and its carrier function. 相似文献
8.
Simard P Lace N Gowans S Quintana-Rizzo E Kuczaj SA Wells RS Mann DA 《The Journal of the Acoustical Society of America》2011,130(5):3068-3076
Dolphins routinely use sound for social purposes, foraging and navigating. These sounds are most commonly classified as whistles (tonal, frequency modulated, typical frequencies 5-10 kHz) or clicks (impulsed and mostly ultrasonic). However, some low frequency sounds have been documented in several species of dolphins. Low frequency sounds produced by bottlenose dolphins (Tursiops truncatus) were recorded in three locations along the Gulf of Mexico. Sounds were characterized as being tonal with low peak frequencies (mean?=?990 Hz), short duration (mean?=?0.069 s), highly harmonic, and being produced in trains. Sound duration, peak frequency and number of sounds in trains were not significantly different between Mississippi and the two West Florida sites, however, the time interval between sounds within trains in West Florida was significantly shorter than in Mississippi (t?=?-3.001, p?=?0.011). The sounds were significantly correlated with groups engaging in social activity (F=8.323, p=0.005). The peak frequencies of these sounds were below what is normally thought of as the range of good hearing in bottlenose dolphins, and are likely subject to masking by boat noise. 相似文献
9.
10.
Inta Kalnina Ruta Bruvere Tija Zvagule Natalija Gabruseva Laura Klimkane Elena Kirilova Imants Meirovics Gunta Kizane 《Journal of fluorescence》2010,20(1):9-17
The fluorescent probe ABM (3-aminobenzanthrone derivative) one of the fluorescent probes synthesized in Riga Technical University
proved to be an excellent, independent model for studying cell membranes. In our work we have investigated the possibility
of using the fluorescent probe ABM for detection of immune state in patients with different pathologies. There is a strong
correlation among all studied ABM spectral parameters, immunological characteristics, clinical and laboratory investigations
of the all observed patients groups. The obtained results suggest that ABM spectral parameters in cell suspension reflect
the alterations of the cellular mechanisms of immunity. Therefore fluorescent method could be used as preliminary screening
test in immune diagnostics instead of more expensive, time consuming methods (subset detection, radioisotope method etc.)
used as routine in clinics. Spectral parameters of ABM reflect a wide range of interrelated (interdependent) characteristics
of cells (physico-chemical state and microviscosity of membrane, proliferating and lipid metabolic activity of cells, distribution
of cells among subsets). The observed change of the studied parameters reflects alterations of the cellular mechanisms of
immunity which is a main focus for its application as preliminary screening test in immune diagnostics. The fluorescence based
method is sensitive, less expensive and time consuming, technically simple and convenient. 相似文献