1.
2.
The author describes some aspects of research on controlled thermonuclear fusion as an energy source, starting in the late 1950s. There was a need for new diagnostic techniques for studying high temperature plasmas. The author proposed a diagnostic for measuring plasma density by probing a deuterium plasma with a deuterium beam and measuring the proton production from the D-D nuclear reaction. By the mid 1960s, it was possible to do so. After carrying out a D-D measurement, the author suggested switching over to an H2+ beam and looking for an H+ signal. The H+ was loud and clear and that was the last of the nuclear measurements. One of the first things done using the molecular break-up of the H2+ to measure the density of the hollow cathode arc plasma was a study of a coherent instability. The frequency response wasn't sufficient to measure the instability directly, so a Langmuir probe was used to detect the instability. The Langmuir probe gave a signal from a fixed spatial location but the beam probe signal was swept across the plasma giving 2D spatial resolution. This was the first detailed mapping of a plasma instability. Attempts to apply the ion beam probe to measuring the plasma current density in the ST Tokamak are described. Heavy ion beam probing measurements using hollow cathode arcs as target plasmas made it possible to measure Te at low temperatures and to identify space potential fluctuations. Installation of a beam probe on the Laser Initiated Target Experiment are described, along with work on the ELMO Bumpy Torus, the VERSATOR Tokamak, TMX, TEXT, ISX-B, the Ergodic Magnetic Limiter and ATF  相似文献   
3.
Two-dimensional electron temperature and density data have been obtained in the midplane of the non-axisymmetric magnetic confinement device ELMO Bumpy Torus (EBT) through the use of a heavy ion beam probe. This beam probe differs from others operated on toroidal or open magnetic geometries in its combination of complete computer control with the steady-state nature of EBT which allows, under normal operating conditions, for extensive calibration of the system in situ, minimizing both alignment and acquisition errors, along with the use of synchronous detection to dramatically improve the quality of the detected signal over what is typically possible in fast pulse devices. These techniques are important and applicable to long pulse devices where the beam probe may be an ideal diagnostic to measure, for example, parameters of the edge plasma. While the EBT beam probe was implemented to obtain profiles of plasma space potential, we have found that it can also be used effectively to measure the temperature and density profiles in the midplane between magnetic field coils. The data obtained support the contention that the formation of a hollow temperature profile in the T-Mode sufficiently inverts the plasma pressure such that stability of the core plasma would be expected even without diamagnetic effects from the hot electron rings which have previously been considered essential  相似文献   
4.
A heavy ion beam probe was used to study the characteristics of density and potential fluctuations in the TEXT tokamak. Fluctuations of density and space potential are nearly Boltzmann like, n˜/n~φ˜/kTe, near the edge of the plasma (0.80.9). The turbulent E&oarr;×B&oarr; radial particle flux is sufficient to account for all of the particle loss from the tokamak. No poloidal asymmetries, within a poloidal angle range of about 70°, are observed in the fluctuation levels. The fluctuation spectral shape, the density potential phase angle, and the fluctuation propagation speed show a strong radial dependence  相似文献   
5.
There has been substantial progress over the last several years in understanding aspects of the functional neuroanatomy of language. Some of these advances are summarized in this review. It will be argued that recognizing speech sounds is carried out in the superior temporal lobe bilaterally, that the superior temporal sulcus bilaterally is involved in phonological-level aspects of this process, that the frontal/motor system is not central to speech recognition although it may modulate auditory perception of speech, that conceptual access mechanisms are likely located in the lateral posterior temporal lobe (middle and inferior temporal gyri), that speech production involves sensory-related systems in the posterior superior temporal lobe in the left hemisphere, that the interface between perceptual and motor systems is supported by a sensory-motor circuit for vocal tract actions (not dedicated to speech) that is very similar to sensory-motor circuits found in primate parietal lobe, and that verbal short-term memory can be understood as an emergent property of this sensory-motor circuit. These observations are considered within the context of a dual stream model of speech processing in which one pathway supports speech comprehension and the other supports sensory-motor integration. Additional topics of discussion include the functional organization of the planum temporale for spatial hearing and speech-related sensory-motor processes, the anatomical and functional basis of a form of acquired language disorder, conduction aphasia, the neural basis of vocabulary development, and sentence-level/grammatical processing.  相似文献   
6.
The technique for measuring electron temperature with an ion beam probe has been refined, the time resolution reduced and the limitations evaluated. The technique involves sequentially probing the same volume of plasma with beams of different ion species and using the observed secondary ion currents and the known ionizing cross sections to evaluate the electron temperature. Spatial resolution is less than 0.1 cm3 and the time required to obtain a radial temperature profile is presently 10 msec. Detailed measurements have been made on a hollow cathode discharge and the results compared with Langmuir probe and spectroscopic data. Quantitative results can only be obtained with K+ -Na+ beams due to the lack of cross sections for other ion species. Better experimental data has been obtained with Rb+ and Cs+ beams but they cannot be reduced to Tee Theoretical cross sections provide qualitative indications of the system behavior but are not sufficiently accurate to permit quantitative data reduction.  相似文献   
7.
A heavy ion beam probe has been used to measure the radial space potential distribution in the central cell of TMX. This was the first beam probe system to utilize computer control, CAMAC instrumentation, and fast time response for broadband fluctuation capabilities. The fast time response was obtained using off-line processing of the energy analyzer detector signals and wideband transimpedance amplifiers. The on-axis space potential was found to be 300-400 V, with φe/Tec~8. The radial potential profile is parabolic when gas box fueling is used. The frequency of observed fluctuations was found to agree with the E×B plasma rotation frequency during the discharge. The measured Tl++ secondary ion current level is consistent with calculations, given reasonable assumptions for beam attenuation  相似文献   
8.
9.
Periprosthetic infections are life-threatening complications that occur in about 6% of medical device insertions. Stringent sterile techniques have reduced the incidence of infections, but many implant patients are at high risk for infection, especially the elderly, diabetic, and immune compromised. Moreover, because of low vascularity at the site of the new implant, antibiotic prophylaxis is often not effective. To address this problem, we designed a covalent modification to titanium implant surfaces to render them bactericidal. Specifically, we aminopropylated titanium, a widely used implant material and extended a tether by solid phase coupling of ethylene glycol linkers, followed by solid phase coupling of vancomycin. Vancomycin covalently attached to titanium still bound soluble bacterial peptidoglycan, reduced Staphylococcus aureus colony-forming units by 88% +/- 16% over 2 hr, and retained antibacterial activity upon a repeated challenge.  相似文献   
10.
The performance of a feedback controlled electrostatic energy analyzer has been investigated for use as the basic detection mechanism in an ion beam probe plasma diagnostic system. This system provides the only direct, spatially resolved measurement of plasma space potential. The principles involved in analyzer operation are presented, leading to an analyzer system with a design entrance angle of 33°. The voltage correction function which results when the probing beam is swept across the plasma has been measured experimentally and is in excellent agreement with theoretical predictions. The measured amplitude and phase response of the system show that the entire analyzer/detector system may be modeled as a linear feedback system. Finally, a dual beam technique is described for making absolute space potential measuremermts and is substantiated with experimental data from an arc plasma using a Rb-K combination.  相似文献   