首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   31篇
  免费   0篇
化学   4篇
数学   1篇
物理学   26篇
  2021年   1篇
  2019年   1篇
  2009年   1篇
  2008年   1篇
  2007年   5篇
  2006年   2篇
  2005年   3篇
  2004年   3篇
  2003年   3篇
  2002年   2篇
  2000年   4篇
  1999年   1篇
  1998年   1篇
  1997年   3篇
排序方式: 共有31条查询结果,搜索用时 15 毫秒
1.
Yelin D  Yun SH  Bouma BE  Tearney GJ 《Optics letters》2005,30(14):1794-1796
We present a novel heterodyne approach for performing fast, three-dimensional spectrally encoded imaging. Volumetric data of a volunteer's finger and of coin surfaces were acquired at a rate of 5 volume sets per second with a depth resolution of 145 microm.  相似文献   
2.
Motz JT  Yelin D  Vakoc BJ  Bouma BE  Tearney GJ 《Optics letters》2005,30(20):2760-2762
A method for obtaining fluorescence images with a high number of resolvable points by using spectral and frequency encoding is presented. Broadband excitation light is encoded with a wavelength-dependent frequency modulation and dispersed onto the sample with a grating to simultaneously illuminate an entire image line. The Fourier transform of the frequency-encoded fluorescence emission provides one line of the image. Mechanical scanning along a direction orthogonal to the wavelength-encoded axis allows creation of the two-dimensional fluorescent image. This method is applicable for developing submillimeter diameter endoscopes. The principles of the technique are validated by imaging indocyanine green fluorescence in microfluidic channels.  相似文献   
3.
Yelin D  Bouma BE  Yun SH  Tearney GJ 《Optics letters》2004,29(20):2408-2410
Endoscopes employing a single optical fiber may have advantages over conventional fiber-bundle or CCD array imaging techniques, including the potential for greater flexibility and miniaturization. Although single-mode fibers can provide superior resolution compared with multimode fibers, they are prone to increased speckle noise and suffer from limited optical throughput and reduced depth of field. We demonstrate the use of a double-clad fiber for single-mode illumination and multimode detection to achieve high-resolution, reduced-speckle imaging with high optical throughput and a large depth of field.  相似文献   
4.
An ultrahigh-speed spectral domain optical coherence tomography (SD-OCT) system is presented that achieves acquisition rates of 29,300 depth profiles/s. The sensitivity of SD-OCT and time domain OCT (TD-OCT) are experimentally compared, demonstrating a 21.7-dB improvement of SD-OCT over TD-OCT. In vivo images of the human retina are presented, demonstrating the ability to acquire high-quality structural images with an axial resolution of 6 microm at ultrahigh speed and with an ocular exposure level of less than 600 microW.  相似文献   
5.
A signal-to-noise ratio (SNR) analysis is presented for optical coherence tomography (OCT) signals in which time-domain performance is compared with that of the spectral domain. A significant SNR gain of several hundredfold is found for acquisition in the spectral domain. The SNR benefit is demonstrated experimentally in a hybrid time-domain-spectral-domain OCT system.  相似文献   
6.
Yelin D  Bouma BE  Iftimia N  Tearney GJ 《Optics letters》2003,28(23):2321-2323
A method for three-dimensional surface measurements with phase-sensitive spectrally encoded imaging is demonstrated. Both transverse and depth information is transmitted through a single-mode optical fiber, allowing this scheme to be incorporated into a miniature probe. This approach is demonstrated by measurement of the profile of a lens surface and by three-dimensional imaging of the face of a small doll.  相似文献   
7.
Oh WY  Vakoc BJ  Yun SH  Tearney GJ  Bouma BE 《Optics letters》2008,33(12):1330-1332
We demonstrate a novel high-speed polarization-sensitive optical frequency domain imaging system employing high-speed polarization modulation. Rapid and continuous polarization modulation of light prior to illumination of the sample is accomplished by shifting the frequency of one polarization eigenstate by an amount equal to one quarter of the digitization sampling frequency. This approach enables polarization-sensitive imaging with a single detection channel and overcomes artifacts that may arise from temporal variations of the birefringence in fiber-optic imaging probes and spatial variation of birefringence in the sample.  相似文献   
8.
There are few novel therapeutic options available for companion animals, and medications rely heavily on repurposed drugs developed for other species. Considering the diversity of species and breeds in companion animal medicine, comprehensive PK exposures in the companion animal patient is often lacking. The purpose of this paper was to assess the pharmacokinetics after oral and intravenous dosing in domesticated animal species (dogs, cats, and horses) of a novel soluble epoxide hydrolase inhibitor, EC1728, being developed for the treatment of pain in animals. Results: Intravenous and oral administration revealed that bioavailability was similar for dogs, and horses (42 and 50% F) but lower in mice and cats (34 and 8%, respectively). Additionally, clearance was similar between cats and mice, but >2× faster in cats vs. dogs and horses. Efficacy with EC1728 has been demonstrated in mice, dogs, and horses, and despite the rapid clearance of EC1728 in cats, analgesic efficacy was demonstrated in an acute pain model after intravenous but not oral dosing. Conclusion: These results demonstrate that exposures across species can vary, and investigation of therapeutic exposures in target species is needed to provide adequate care that addresses efficacy and avoids toxicity.  相似文献   
9.
10.
A nonreciprocal fiber-optic interferometer is demonstrated in an optical coherence tomography (OCT) system. The increased power efficiency of this system provides a 4.1-dB advantage over standard Michelson implementations. In addition, a new linear-scanning fiber-optic catheter is demonstrated that avoids the rotary optical junction that is required in circumferential scanning systems. These advancements have permitted the clinical implementation of OCT imaging in the human gastrointestinal tract.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号