首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   44篇
  免费   1篇
化学   22篇
数学   15篇
物理学   8篇
  2022年   2篇
  2021年   2篇
  2020年   3篇
  2019年   6篇
  2018年   2篇
  2017年   3篇
  2016年   3篇
  2014年   6篇
  2013年   4篇
  2012年   3篇
  2011年   2篇
  2010年   2篇
  2008年   1篇
  2007年   1篇
  2003年   1篇
  2000年   2篇
  1990年   1篇
  1988年   1篇
排序方式: 共有45条查询结果,搜索用时 31 毫秒
1.
Journal of Thermal Analysis and Calorimetry - This work introduces the determination of the optimum values of the design parameters in a tube with loose-fit perforated twisted tapes. The effects of...  相似文献   
2.
A novel flow-injection amperometric method was proposed for the sensitive and enzymeless determination of hydrogen peroxide based on its electrocatalytic reduction at a palladium nanoparticle-modified pretreated pencil graphite electrode in a laboratory-constructed electrochemical flow cell. Cyclic voltammograms of the unmodified and modified electrodes were recorded in pH 7.0 phosphate buffer containing 0.10 M KCl at a scan rate of 50?mV s?1 for the investigation of electrocatalytic reduction of hydrogen peroxide at the palladium nanoparticle-modified pretreated pencil graphite electrode. Cyclic voltammograms of the pretreated pencil graphite electrode revealed an irreversible oxidation peak and a weak reduction peak of hydrogen peroxide at +1100?mV and –450?mV vs. an Ag/AgCl/KCl saturated reference electrode. However, the reduction of hydrogen peroxide was observed at –100?mV with an increase in current in the cyclic voltammograms of the palladium nanoparticle-modified pretreated pencil graphite electrode compared to the unmodified electrode. These results indicate that the palladium nanoparticle-modified pretreated pencil graphite electrode exhibits efficient electrocatalytic activity for the reduction of hydrogen peroxide. A linear concentration range was obtained between .01 and 10.0?mM hydrogen peroxide with a detection limit of 3.0 µM from flow injection amperometric current–time curves recorded in pH 7.0 phosphate buffer at –100?mV and a 2.0?mL min?1 flow rate. The novelty of this work relies on its use of a laboratory-constructed flow cell constructed for the pencil graphite electrode using these inexpensive, disposable, and electrochemically reactive modified electrodes for the amperometric determination of hydrogen peroxide in a flow injection analysis system.  相似文献   
3.
On the basis of a well-established binomial structure and the so-called Poisson-Lindley distribution,a new two-parameter discrete distribution is introduced.Its...  相似文献   
4.
The billiard ball model, a classical mechanical system in which all parameters are real variables, can perform all digital computations. An eight-state, 11-neighbor reversible cellular automaton (an entirely discrete system in which all parameters are integer variables) can simulate this model. One of the natural problems for this system is to determine the shape of a container so that the initial specific distribution of gas molecules eventually leads to a predetermined distribution. This problem is PSPACE-complete. Related intractable and decidable problems are discussed as well.  相似文献   
5.
One of the major problems in amperometric biosensors based on detection of H2O2 produced by enzymatic reaction between oxidase enzymes and substrate is the interference of redox active compounds such as ascorbic acid (AA), dopamine (DA) and uric acid (UA). To minimize these interferences, sodium bismuthate was used for the first time as an insoluble pre‐oxidant in the flow injection (FI) amperometric glucose biosensor at a Glucose oxidase (GOx) immobilized Pt/Pd bimetallic modified pre‐anodized pencil graphite electrode (p.PGE). In this context, these interfering compounds were injected into a flow injection analysis (FIA) system using an injector which was filled with NaBiO3. Thus, these interferents were converted into their redox inactive oxidized forms before reaching the electrode in the flow cell. While glucose was not influenced by the pre‐oxidant in the injector, the huge oxidation peak currents of the interferents decreased significantly in the biosensor. FI amperometric current time curves showed that the AA, DA and UA were minimized by 96 %, 86 %, and 98 % respectively, in the presence of an equivalent concentration of interferences in a 1.0 mM glucose solution. The proposed FI amperometric glucose biosensor exhibits a wide linear range (0.01–10 mM, R2=0.9994) with a detection limit of 2.4×10?3 mM. Glucose levels in the artificial serum and two real samples were successfully determined using the fabricated FI amperometric biosensor.  相似文献   
6.
Two new macrocyclic dibenzotetraaza[14]annulene (DBTAA) compounds with indolenine ( 5 ) and pyridoindolenine ( 6 ) moieties were synthesized and characterized by spectroscopy. Both DBTAAs exhibit strong UV-Vis absorption properties in the Soret band region. The theoretical second-order nonlinear optical property, electric dipole moment (μ), dispersion-free dipole polarizability (α) and first hyper-polarizability values were calculated by density functional theory and time dependent density functional theory. The ab-initio quantum mechanical calculation by time-dependent Hartree-Fock method was utilized to investigate the dynamic dipole polarizabilities, dynamic second-order, static, and dynamic third-order (γ) hyper-polarizabilities of the DBTAAs. The configuration interaction technique of all doubly occupied molecular orbitals possesses theoretically defined single-photon absorption (OPA) specifications for the examined structures. The computed maximum OPA wavelengths on both macrocyclic compounds coincide with the preceding measurement outcomes.  相似文献   
7.
The physical–chemical properties and fatty acid composition of sheep subcutaneous, tallow, intestinal, and tail fats were determined. Sheep fat types contained C16:0, C18:0, and C18:1 as the major components of fatty acid composition (19.56–23.40, 20.77–29.50, 32.07–38.30%, respectively). Differential scanning calorimetry (DSC) study revealed that two characteristic peaks were detected in both crystallization and melting curves. Major peaks (T peak) of tallow and intestinal fats were similar and determined as 31.25–24.69 and 7.44–3.90 °C, respectively, for crystallization peaks and 15.36–13.44 and 45.98–44.60 °C, respectively, for melting peaks in DSC curves; but those of tail fat (18.29 and −2.13 °C for crystallization peaks and 6.56 and 33.46 °C for melting peaks) differed remarkably from those of other fat types.  相似文献   
8.
The advances in the technological infrastructure and in the Internet led electronic auctions to become popular. With online sites, people buy/sell inexpensive products/services through auctions. In this paper, we develop an interactive approach that provides aid to both the buyer and the bidders in a bi-attribute, multi-item auction environment. Our approach is applicable for both reverse and forward auctions. We test our approach for underlying linear preference functions of the buyer. We also adapt it as a heuristic for the case the buyer has a nonlinear preference function. The test results show that our approach works well.  相似文献   
9.
In this work, we classify and calculate spectra such as point spectrum, continuous spectrum and residual spectrum over sequences spaces ?, c?,c and c0 according to a new matrix operator W which is obtained by matrix product.  相似文献   
10.
The goal of this study is to determine the most stable tautomeric forms, and their ground state conformers of 4′-nitroazobenzene-2,4-diol and 4-methyl-4′-nitroazobenzene-2,6-diol compounds. The calculations have shown that the most stable tautomeric forms of the compounds are hydrazo form for 4′-nitroazobenzene-2,4-diol and azo form for 4-methyl-4′-nitroazobenzene-2,6-diol. Besides, the vibrational frequencies, 1H and 13C NMR shifts, frontier molecular orbital’s energies for the tautomeric forms of the compounds calculated by using density functional theory-B3LYP method with 6-311G(d) basis set were interpreted. All the assignments of the theoretical frequencies were identified by potential energy distribution (PED) analysis. Generally, theoretical spectral results were seen to be in a good agreement with the corresponding experimental data.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号