Absolute OH· concentrations and relative H-atom and O-atom profiles have been measured in a laminar, co-flowing methane/air diffusion flame burning at atmospheric pressure. Laser absorption and laser-induced fluorescence methods were used to probe the A2X2IIitransition in OH·. The maximum OH· concentration is found to be 1.8±0.2 ×1016 cm–3 (mole fraction =5.0×10–3) at a temperature of 2080 K, which is twice the value calculated assuming local total equilibrium but less than half that predicted from partial equilibrium (O2+H2 2OH·). Multiphoton ionization (2+1 process at 243 nm) has been used to detect H atoms, while laser-induced fluorescence at 845 nm excited by two-photon absorption at 226 nm was employed to observe O atoms. In both cases it was found that low photon intensities (2×108W/cm2) and a retroreflected beam, Doppler-free geometry was required in order to avoid the photolytic production of the species of interest. For all of the concentration profile data it is necessary to correct the raw signals for variations in collisional quenching. In the case of the multiphoton ionization measurements the variation in electron detection sensitivity as a function of flame position must be accounted for as well. Establishing absolute H-atom and O-atom concentrations is discussed in terms of partial equilibrium considerations and detailed flame structure calculations.Formerly the National Bureau of Standards 相似文献
The recent development of an automated surface plasmon resonance technology for the measurement of biomolecular interactions (Pharmacia BIAcore) has provided new opportunities for the detection and analysis of protein-protein interactions. In the BIAcore, detection is based on changes in surface plasmon resonance which are monitored optically. Changes in surface plasmon resonance correspond to changes in surface concentration of macromolecules and can be monitored in real time.
We have found that the detection sensitivity obtainable with this technology (ng/ml concentrations of specific ligands are readily detectable for many applications) is complementary “in a bidirectional manner” to micropreparative HPLC. Thus micropreparative HPLC may be used to purify and characterise reagents for the biosensor, whilst the biosensor may be used to define chromatographic parameters such as elution conditions for affinity chromatography or serve as an affinity detector for fractions obtained during chromatographic purification.
Examples of such applications, including the potential of the biosensor to search for and monitor the purification of unknown ligands for which the target molecule has been identified, are shown. In particular, the use of the biosensor to monitor the purification of soluble epidermal growth factor receptor from A431 cell conditioned media is demonstrated. 相似文献
Analytical and Bioanalytical Chemistry - A combination of differential solvent extraction based on physical chemical properties of the species involved and differential pulse polarography has been... 相似文献
The characterisation of selected indole alkaloids in a quadrupole ion trap mass spectrometer is presented. Fragmentation profiles for tryptamine, 5-hydroxytryptamine (5-HT), N'-methyl 5-hydroxytryptamine (N'-methyl 5-HT), N',N'-dimethyl 5-hydroxytryptamine (bufotenine), N',N',N'-trimethyl 5-hydroxytryptamine (5-HTQ), and N',N'-dimethyl 5-methoxytryptamine (5-MeODMT) are presented with proposed structures given for each product ion observed. Such MS(n) experiments can be used to differentiate the isobaric molecular ions of the compounds 5-HTQ (M(+)) and 5-MeODMT (MH(+)). The quantitative determination of certain indole alkaloids in the skin secretions of the Australian Golden Bell frog, Litoria aurea, by LC/ESI-ion trap MS is also presented. The concentrations of 5-HT, N'-methyl 5-HT and 5-HTQ were found to be 2.68, 0.26 and 0.54 microg per mg of skin secretion, respectively. 相似文献
Single crystal X-ray analysis of the 2:1 acetonitrile complex of 18-crown-6 is reported. Crystals of the complex are monoclinic,P21/n, witha=9.123(3),b=8.524(3),c=13.676(4) Å, =104.68(3)°, andDc=1.118 g cm–3 forZ=2. The complex lies on a center of symmetry, with the crown in theD3d conformation. Methyl groups of the acetonitrile molecules have weak interactions with the crown oxygen atoms, and are tilted 31.7° from the host's threefold axis. Methyl hydrogen atoms are rotationally disordered about the acetonitrile axis.
Supplementary Data relating to this article are deposited with the British Library as Supplementary Publication No. SUP 82057 (12 pages). 相似文献
European Union Member States are now required to monitor poultry meat for the presence of coccidiostat residues. Among other factors contributing to the production of residue-free food is the ability of animal feed manufacturers to produce medication-free feedstuffs, ensuring the proper observance of withdrawal periods prior to slaughter. Carry-over of medication was investigated in a local poultry feed mill that was using monensin as its principal coccidiostat for broilers. Monensin, at levels in excess of 5% of the therapeutic dose (approximately 110 mg kg-1), was present in 22.5% of 40 withdrawal feeds. Subsequent studies in the mill indicated that most of the contamination occurred during the processing of feeds after the mixing stage. The mill altered its manufacturing process as a result of this study. The consequence of this was that the incidence of monensin withdrawal feeds, at levels greater than 5% of the therapeutic dose, fell from 22.5 to 2.5%. This collaborative study has helped the feed compounder to produce more effective withdrawal feeds, thereby reducing the potential exposure of consumers to unwanted residues of monensin in poultry meat. 相似文献
Summary Reverse phase high-performance liquid chromatography with ultra-violet detection has been used for the simultaneous identification and determination of ampicillin, cloxacillin and some of their degradation products following their extraction from an intramammary preparation used in veterinary medicine. Extraction of the intramammary base into petroleum ether (40–60°C) and partition of the penicillins into the mobile phase gave a mean recovery of 100.8% for ampicillin with coefficient of variation of 1.0 and 103.4% for cloxacillin with coefficient of variation of 1.2 (n=6). Using optimised HPLC conditions ampicillin eluted in approximately 2 min and cloxacillin in approximately 8 min. The overall method was found to be stability indicating, since cloxacillin and ampicillin eluted independently of their degradation products. 相似文献
The application of ruthenium dioxide (RuO2) modified electrodes to the electrocatalytic detection of the saccharide-related antibiotics streptomycin, novobiocin and neomycin, at low fixed potentials, was investigated. The RuO2-modified graphite - epoxy composite electrodes give extremely stable and reproducible catalytic oxidation currents for these antibiotics at potentials as low as +0.2 V (versus Ag - AgCl). Rapid quantification at the micromolar level is therefore possible. Standard calibration graphs for streptomycin and neomycin yielded slopes of 4.43 and 0.08 nA microM-1 over the linear ranges of 1.5 x 10(-6) - 2.5 x 10(-4) and 1 x 10(-5) - 2 x 10(-3) M, respectively. Owing to its catalytic oxidation by the RuIII - RuIV couple, rather than the RuIV - RuVI transition (which catalyses the oxidation of streptomycin and neomycin), novobiocin could be detected at a lower (+0.2 V) potential, with a sensitivity of 1.31 nA microM-1. Detection limits of 1.5, 6.0 and 10 microM were obtained for streptomycin, novobiocin and neomycin, respectively. These catalytic surfaces can be renewed (by polishing), with a surface-to-surface reproducibility of 6.5% for the detection of 5 x 10(-5) M streptomycin. The analytical application of RuO2-modified carbon paste electrodes to the analysis of these antibiotics by flow injection was investigated, with a view to liquid chromatographic separation with electrochemical detection applications. 相似文献