首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
化学   3篇
数学   1篇
  2003年   1篇
  2002年   1篇
  1991年   1篇
  1987年   1篇
排序方式: 共有4条查询结果,搜索用时 15 毫秒
1
1.
Densities and sound velocities of binary mixtures of cyclohexanone, 2-butanone, 1,4-dioxane and 1,2-dimethoxyethane were measured at 298.15 K and also the densities at 303.15 K. Excess volumes were determined from densities. Isentropic compressibilities were determined from densities and sound velocities, and excess thermal expansion factors were determined from excess volumes of two temperatures. Excess isothermal compressibilities and excess isochoric heat capacities were then estimated using excess isobaric heat capacities previously reported. Excess volumes and excess isentropic and isothermal compressibilities were negative except for cyclohexanone+1,4-dioxane system. This revised version was published online in August 2006 with corrections to the Cover Date.  相似文献   
2.
The uneven distribution of ventilation—perfusion ratios ( ) in diseased lungs is the major cause of arterial hypoxemia. Farhi and Yokoyama (1967) and Yokoyama and Farhi (1967) were the first who used physiologically inert gases as indicator gases to assess the uneven distribution of Wagner and his coworkers in San Diego (1977b) extended the method and elaborated the multiple inert gas elimination technique in which blood flows in 50 compartments with different were estimated based on data for 6 indicator gases. They analyzed the indicator gas data through an enforced smoothing technique with the ridge regression. To get smooth distributions, they introduced a weighting function for compartments and an additional treatment for the non-negativity of the blood flow. The weighting function was empirically obtained. We analyzed the data without putting any weights on compartments nor any additional treatment for non-negativity of blood flow. The analytical method in the present study was a modified Newton method, which is one of the enforced smoothing method. Our method was capable of recovering all distribution patterns that were found through the method reported by Wagner et al. (1977b).  相似文献   
3.
Excess isobaric heat capacities of mixture (2-methoxyethanol+water) were measured at T=298.15 K and excess enthalpies at T=293.15 and 298.15 K. Excess enthalpies were extremely exothermic, up to -1290 J mol-1 atT=293.15 K and -1240 J mol-1 at T=298.15 K. Excess isobaric heat capacities were positive and very large, approximately 9 J K-1 mol-1 at the maximum. In contrast to the data reported by Page and coworkers, the excess heat capacity data were positive in the entire composition range and there was no change in their signs. Consistently, no crossing was found between the curves of excess enthalpies at T=298.15 and 293.15 K. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   
4.
Abstract A new diagnostic and therapeutic endoscopic system consisting of an excimer pulse dye laser is presented. This report demonstrates the accumulation of hematoporphyrin derivative (HpD) in atheroma as shown by the fluorescence of HpD using this equipment. Atheroma was induced in the aorta of WHHL (Watanabe heritable hyperlipidemic) rabbits, 5 mg kg−1 HpD was injected intravenously and the rabbits were sacrificed 24 h later. The aorta was dissected and the localization of HpD was examined. Characteristic peaks of the fluorescence of HpD at 630, 665 and 690 nm wavelength were detected in the atheromatous lesion. However, in the fatty plaque, the emission peak at 630 nm was lower and the 665 nm peak faded away. No fluorescence with peaks was detected in the normal area. The ratio of fluorescence intensity in atheroma, border zones and normal areas was 10.4 : 5.0 : 1.0. On normal rabbits made atherosclerotic by diet and balloon damage, an ultra thin endoscopic catheter was inserted from the descending aorta of atherosclerotic rabbits under anesthesia. Essentially the same data was obtained by these studies in vivo as was obtained in the in vitro studies. The above data suggests the possibility of future applications of this equipment for diagnosis of atheroma.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号