排序方式: 共有5条查询结果,搜索用时 15 毫秒
1
1.
Chokchai Kaiyasuan Pongsakorn Chasing Phattananawee Nalaoh Praweena Wongkaew Dr. Taweesak Sudyoadsuk Dr. Kanokwan Kongpatpanich Prof. Vinich Promarak 《化学:亚洲杂志》2021,16(16):2328-2337
Herein, two deep-blue emissive molecules ( SAF-PI and SAF-DPI ) are designed and synthesized using spiro[acridine-9,9’-fluorene] as a donor (D) substituted with 2-(3-methylphenyl)-1-phenyl-phenanthro[9,10-d]imidazole as an acceptor (A), forming twisted D−A and A−D−A structures, respectively. The photophysical studies and density functional theory (DFT) calculations reveal that both molecules exhibit hybridized local excited and charge transfer (HLCT) characteristics with deep blue emission color. They are effectively applied as non-doped emitters in OLEDs. Particularly, SAF-PI -based device achieves the high-definition television (HDTV) standard blue color emission peaked at 428 nm with CIE coordinate of (0.156, 0.053), a narrow full width at half maximum of 55 nm, a maximum external quantum efficiency (EQEmax) of 4.57% and an exciton utilization efficiency of 65%. 相似文献
2.
We have examined the anodic stripping voltammetry (ASV) of Cd and Pb at carbon screen printed electrodes modified by an in situ deposited Bi film, and have demonstrated significant cross talk between the stripping peaks of the two metals. A simple and generally applicable method for dealing with this problem is described, based on curve-fitting three-dimensional calibration plots using MATLAB. Non-linear fitting to the calibrations produced coefficients of determination R2 > 0.99 for both metals. We have illustrated use of the plots in conjunction with Bi-plated electrodes by measuring 15 randomly selected mixtures of Cd and Pb of known concentration. 相似文献
3.
4.
Nongnoot Wongkaew Peng He Vanessa Kurth Werasak Surareungchai Antje J. Baeumner 《Analytical and bioanalytical chemistry》2013,405(18):5965-5974
A novel multi-channel poly(methyl methacrylate) (PMMA) microfluidic biosensor with interdigitated ultramicroelectrode arrays (IDUAs) for electrochemical detection was developed. The focus of the development was a simple fabrication procedure and the realization of a reliable large IDUA that can provide detection simultaneously to several microchannels. As proof of concept, five microchannels are positioned over a large single IDUA where the channels are parallel with the length of the electrode finger. The IDUAs were fabricated on the PMMA cover piece and bonded to a PMMA substrate containing the microfluidic channels using UV/ozone-assisted thermal bonding. Conditions of device fabrication were optimized realizing a rugged large IDUA within a bonded PMMA device. Gold adhesion to the PMMA, protective coatings, and pressure during bonding were optimized. Its electrochemical performance was studied using amperometric detection of potassium ferri and ferro hexacyanide. Cumulative signals within the same chip showed very good linearity over a range of 0–38 μM (R 2?=?0.98) and a limit of detection of 3.48 μM. The bonding of the device was optimized so that no cross talk between the channels was observed which otherwise would have resulted in unreliable electrochemical responses. The highly reproducible signals achieved were comparable to those obtained with separate single-channel devices. Subsequently, the multi-channel microfluidic chip was applied to a model bioanalytical detection strategy, i.e., the quantification of specific nucleic acid sequences using a sandwich approach. Here, probe-coated paramagnetic beads and probe-tagged liposomes entrapping ferri/ferro hexacyanide as the redox marker were used to bind to a single-stranded DNA sequence. Flow rates of the non-ionic detergent n-octyl-β-d-glucopyranoside for liposome lysis were optimized, and the detection of the target sequences was carried out coulometrically within 250 s and with a limit of detection of 12.5 μM. The robustness of the design and the reliability of the results obtained in comparison to previously published single-channel designs suggest that the multi-channel device offers an excellent opportunity for bioanalytical applications that require multianalyte detection and high-throughput assays. Figure
Multi-channel microfluidic biosensor with integrated IDUAs for a sandwich nucleic acid hybridization assay 相似文献
5.
Nongnoot Wongkaew Stefanie E. K. Kirschbaum Werasak Surareungchai Richard A. Durst Antje J. Baeumner 《Electroanalysis》2012,24(10):1903-1908
A new strategy of three‐electrode system fabrication in polymer‐based microfluidic systems is described here. Standard lithography, hot embossing and UV‐assisted thermal bonding were employed for fabrication and assembly of the microfluidic chip. For the electrode design the gold working (WE) and counter electrodes (CE) are placed inside a main channel through which the sample solution passes. A silver reference electrode (RE) is embedded in a small side channel containing KCl solution that is continuously pushed into the main channel. In the present work, the overall electrochemical set up and its microfabrication is described. Conditions including silver ion concentration, cyclic voltammetry (CV) settings, and the flow rate of KCl solution in the RE channel were optimized. The electrochemical performance of the three‐electrode system was evaluated by CV and also by amperometric oxidation of ferro hexacyanide ([Fe(CN)6]4?) and ruthenium bipyridyl ([Ru(bipy)3]2+) at 400 mV and 1200 mV, respectively. CV analysis using ferri/ferro hexacyanide showed a stable, quasi‐reversible redox reaction at the electrodes with 96 mV peak separation and an anodic/cathodic peak ratio of 1. Amperometric analysis of the electrochemical species resulted in linear correlation between analyte concentration and current response in the range of 0.5–15 µM for [Fe(CN)6]4?, and 0–1000 µM for [Ru(bipy)3]2+. Upon the given experimental conditions, the limit of detection was found to be 3.15 µM and 24.83 µM for [Fe(CN)6]4? and [Ru(bipy)3]2+, respectively. As a fully integrated three‐electrode system that is fabricated on polymer substrates, it has great applications in microfluidic‐based systems requiring stable electrochemical detection. 相似文献
1