首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
化学   6篇
  2020年   1篇
  2012年   1篇
  2011年   3篇
  2009年   1篇
排序方式: 共有6条查询结果,搜索用时 78 毫秒
1
1.
The synthesis and the chemical physical characterization of new photoluminescent (PL) chromophores and polymers are reported. Chromophores (oligo‐PPV symmetric derivatives ending with amino groups) are strong blue emitters with a PL quantum yield of ~70% in dioxane solution. They have been used to prepare polyamides by reaction with aliphatic acyl dichlorides in which emitting and non emitting units are alternated. PL properties of the synthesized polyamides have been evaluated in solution and reveal a strong blue emission (PL quantum yield ~60%), To increase the solubility of these systems, oligomers have been purposely prepared and then characterized. They show a peculiar white emission when excited in DMF solution; to get insight into this interesting behavior, asymmetric monoacetylated chromophores have been prepared as model compounds for the chromophoric end groups of the polyamide chains. The emission spectra of these compounds reveal a broad excimeric yellow emission which is responsible, along with the blue emission of the inner chromophoric units, of the overall white emission of the oligomers. © 2009 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 47: 2677–2689, 2009  相似文献   
2.
A modified sol–gel method was used to prepare cobalt doped silica thin film with a cobalt content of 10, 20 and 30 mol% (10Co, 20Co and 30Co). The prepared films were annealed at different temperatures in the range 400–1,000 °C, and their structural evolution examined. The mixed valence cobalt oxide, Co3O4, crystallizes only in the sample with the higher cobalt content, while cobalt silicate is the only crystalline phase detected in the sample 10Co and 20Co. Both the cobalt content and the temperature of heat treatment resulted to affect the nature of cobalt species dispersed in the silica matrix. The 30Co was selected for further investigations by FTIR spectroscopy to follow the structural evolution of 30Co film as function of the temperature and UV–Vis to get information on the cobalt valence state. The optical gas-sensing properties of 30Co films, containing Co3O4 as the major cobalt phase, were studied through the measuring of the film transmittance in dry air and in presence of dry air containing variable concentrations of polluting gases, CO and NO2. The 30Co samples resulted to be highly sensitive to CO at room temperature. An explanation for the CO sensing characteristics, at low temperature, was proposed by referring to the physisorption-related mechanics of CO.  相似文献   
3.
The influence of the wine distillation process on methanol content has been determined by quantitative analysis using gas chromatographic flame ionization (GC-FID) detection. A comparative study between direct injection of diluted wine and injection of distilled wine was performed. The distillation process does not affect methanol quantification in wines in proportions higher than 10%. While quantification performed on distilled samples gives more reliable results, a screening method for wine injection after a 1:5 water dilution could be employed. The proposed technique was found to be a compromise between the time consuming distillation process and direct wine injection. In the studied calibration range, the stability of the volatile compounds in the reference solution is concentration-dependent. The stability is higher in the less concentrated reference solution. To shorten the operation time, a stronger temperature ramp and carrier flow rate was employed. With these conditions, helium consumption and column thermal stress were increased. However, detection limits, calibration limits, and analytical method performances are not affected substantially by changing from normal to forced GC conditions. Statistical data evaluation were made using both ordinary (OLS) and bivariate least squares (BLS) calibration models. Further confirmation was obtained that limit of detection (LOD) values, calculated according to the 3sigma approach, are lower than the respective Hubaux-Vos (H-V) calculation method. H-V LOD depends upon background noise, calibration parameters and the number of reference standard solutions employed in producing the calibration curve. These remarks are confirmed by both calibration models used.  相似文献   
4.
We present a first-principles study on the structure-property relationships in MoS2 and WS2 monolayers and their vertically stacked hetero-bilayer, with and without Sulfur vacancies, in order to dissect the electronic features behind their photocatalytic water splitting capabilities. We also benchmark the accuracy of three different exchange-correlation density functionals for both minimum-energy geometries and electronic structure. The best compromise between computational cost and qualitative accuracy is achieved with the HSE06 density functional on top of Perdew–Burke–Ernzerhof minima, including dispersion with Grimme's D3 scheme. This computational approach predicts the presence of mid-gap states for defective monolayers, in accordance with the present literature. For the heterojunction, we find unexpected vacancy-position dependent electronic features: the location of the defects leads either to mid-gap trap states, detrimental for photocatalyst or to a modification of characteristic type II band alignment behavior, responsible for interlayer charge separation and low recombination rates.  相似文献   
5.
The present study evaluated the reliability of the ISO/TS 3632-2 UV-Vis spectrometric method for saffron classification, making experiments on saffron samples to which were added increasing concentrations of common saffron spice adulterants (safflower, marigold and turmeric). The results showed that the ISO/TS 3632-2 method is not able to detect addition of up to 10-20%, w/w, of saffron adulterants. For additions from 20 to 50%, w/w, of the three adulterants, saffron was classified in a wrong category; addition of higher than 50%, w/w, determined variations in the investigated parameters that did not allow identification of the product as "saffron". In all cases, the method did not permit the recognition of the nature of the adulterant. On the contrary, the specificity of the HPLC/PDA/MS technique allowed the unequivocal identification of adulterant characteristic marker molecules that could be recognized by the values of absorbance and mass. The selection of characteristic ions of each marker molecule has revealed concentrations of up to 5%, w/w, for safflower and marigold and up to 2% for turmeric. In addition, the high dyeing power of turmeric allowed the determination of 2%, w/w, addition using exclusively the HPLC/PDA technique.  相似文献   
6.
A capillary GC-flame ionization detection (FID) method to determine volatile compounds (ethyl acetate, 1,1-diethoxyethane, methyl alcohol, 1-propanol, 2-methyl-1-propanol, 2-methyl-1-butanol, 3-methyl-1-butanol, 1-butanol, and 2-butanol) in wine was investigated in terms of calculation of detection limits and calibration method. The main objectives were: (1) calculation of regression coefficient parameters by ordinary least-squares (OLS) and bivariate least-squares (BLS) regression models, taking into account errors in both axes; (2) estimation of linear dynamic range (LDR) according to International Conference on Harmonization recommendations; (3) performance evaluation of a method by using three different internal standards (ISs) such as acetonitrile, acetone, and 1-pentanol; (4) evaluation of LODs according to the U.S. Environmental Protection Agency (EPA) 3sigma approach and the Hubaux-Vos (H-V) method; (5) application of H-V theory to a gas chromatographic analytical method and to a food matrix; and (6) accuracy assessment of the method relative to methyl alcohol content through a Unione Italiana Vini (UIV) interlaboratory proficiency test. Calibration curves calculated via BLS and OLS show similar slopes, while intercepts are closer to zero in the first case, independent of the chosen IS. The studied ISs show a substantially equivalent behavior, even though the IS closer to the analyte retention time seems to be more appropriate in terms of LDR and LOD. Results indicate an underestimation of LODs using the EPA 3sigma approach instead of the more realistic H-V method, both with OLS and BLS regression models. Methanol contents compared with UIV average values indicate recovery between 90 and 110%.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号