首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   112篇
  免费   0篇
化学   76篇
晶体学   2篇
力学   19篇
物理学   15篇
  2022年   5篇
  2021年   6篇
  2020年   4篇
  2019年   5篇
  2018年   10篇
  2017年   2篇
  2016年   8篇
  2015年   3篇
  2014年   3篇
  2013年   4篇
  2012年   6篇
  2011年   9篇
  2010年   7篇
  2009年   11篇
  2008年   4篇
  2007年   5篇
  2006年   3篇
  2005年   6篇
  2004年   5篇
  2003年   1篇
  2002年   2篇
  2001年   1篇
  2000年   1篇
  1985年   1篇
排序方式: 共有112条查询结果,搜索用时 15 毫秒
1.
Derivative techniques for analytical signal processing are useful for solving some noise and signal resolution problems in various fields of study such as titrimetry, spectrophotometry, chromatography and electrochemistry. The broad use of these techniques, however, is often limited by costly inflexible built-in software packages in commercial analytical instruments. We propose here the application of commercial simple software packages such as Microsoft® Excel and Microcal Origin for signal smoothing and fitting, and for obtaining derivative analytical signals in batch and flow-based analyses, including potentiometric titration, spectrophotometry, chromatography, voltammetry and sequential injection analysis (SIA). The worldwide (especially Excel) software packages are easy-to-use for less experienced users and have also capabilities for advanced users, and therefore employing such packages can result in expansion of useful derivative techniques. We demonstrate application of the available package-aided derivative capabilities for enhancing some chemical analyses, including potentiometric acid–base titration, Bradford assay of protein, chromatographic separation of ajmaline and reserpine and anodic stripping voltammetry of copper. The derivative signals from smoothed and fitted curves offer better accuracy and precision, even for non-resolving peaks and tailing peaks. In some cases, the optimization of experimental conditions is not further required, which can lead to fast method development.  相似文献   
2.
A simple, sensitive and selective method for the determination of bromide in seawater by using a flow injection/stopped-flow detection technique was examined. The detection system was developed for a new kinetic-spectrophotometric determination of bromide in the presence of chloride matrix without any extraction and/or separation. The detection was based on the kinetic effect of bromide on the oxidation of methylene blue (MB) with hydrogen peroxide in a strongly acidic solution. Large amounts of chloride could enhance the sensitivity of the method as an activator. The decolorisation of the blue color of MB was used for the spectrophotometric determination of bromide at 746 nm. A stopped-flow approach was used to improve the sensitivity of the measurement and provide good linearity of the calibration over the range of 0-3.2 μg ml−1 of bromide. The relative standard deviation was 0.74% for the determination of 2.4 μg ml−1 bromide (n = 5). The detection limit (3σ) was 0.1 μg ml−1 with a sampling frequency of 12 h−1. The influence of potential interfering ions was studied. The proposed method was applied to the determination of bromide in seawater samples and provided satisfactory results.  相似文献   
3.
This review focuses on the developments of the various parts of instrumentation and the operation of low to medium pressure flow injection and sequential injection chromatography (FIC and SIC) systems. The report and discussion include solution delivery system, separation column, flow cell and detector, mobile phase management, and online sample pretreatment. Applications of FIC and SIC and their differences as compared to HPLC are also presented.  相似文献   
4.

Pd nanoparticles supported on Bi2WO6 nanoplates used for visible-light-driven photocatalyst were successfully synthesized by photoreduction deposition method under visible-light irradiation. Different analytical techniques including X-ray diffraction, X-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy, scanning electron microscopy, transmission electron microscopy and photoluminescence spectroscopy revealed that face-centered cubic metallic Pd nanoparticles were uniformly loaded on top of orthorhombic Bi2WO6 nanoplates to form heterostructure Pd/Bi2WO6 nanocomposites. Photocatalytic activities of pure Bi2WO6 sample and heterostructure Pd/Bi2WO6 nanocomposites were studied through the photodegradation of rhodamine B (RhB) under visible-light irradiation. The photocatalytic efficiency of Bi2WO6 was increased to the highest by being loaded with 5 wt% Pd and then decreased by being loaded with 10 wt% Pd. The improved photocatalytic efficiency caused by high-efficiency diffusion and separation of photo-generated charge carriers was explained and can lead to superior photodegradation of RhB under visible-light irradiation.

  相似文献   
5.
The application of nanofluids in energy systems is developing day by day. Before using a nanofluid in an energy system, it is necessary to measure the properties of nanofluids. In this paper, first the results of experiments on the thermal conductivity of MgO/ethylene glycol (EG) nanofluids in a temperature range of 25–55 °C and volume concentrations up to 5 % are presented. Different sizes of MgO nanoparticles are selected to disperse in EG, including 20, 40, 50, and 60 nm. Based on the results, an empirical correlation is presented as a function of temperature, volume fraction, and nanoparticle size. Next, the model of thermal conductivity enhancement in terms of volume fraction, particle size, and temperature was developed via neural network based on the measured data. It is observed that neural network can be used as a powerful tool to predict the thermal conductivity of nanofluids.  相似文献   
6.
A flow injection (FI) in-valve-mini-column packed with Chelex-100 resin is proposed for on-line sample pretreatment for some metal ions, namely, Cd(II), Pb(II) and Zn(II), prior to simultaneous determination using ion chromatography (IC). A solution containing a mixture of the cations was first passed through the in-valve-mini-column, followed by on-line elution. The eluate was then flowed further to an injection valve and was injected into an ion chromatograph. Conditions of the system were optimized. A single standard calibration was possible. The recoveries of cations were found to be in the range of 95–105%. The developed method was applied to the accurate analysis of zinc ore samples.  相似文献   
7.
Two-phase air–water flow characteristics are experimentally investigated in horizontal circular micro-channels. Test sections are made of fused silica. The experiments are conducted based on three different inner diameters of 0.53, 0.22 and 0.15 mm with the corresponding lengths of 320, 120 and 104 mm, respectively. The test runs are done at superficial velocities of gas and liquid ranging between 0.37–42.36 and 0.005–3.04 m/s, respectively. The flow visualisation is facilitated by systems mainly including stereozoom microscope and high-speed camera. The flow regime maps developed from the observed flow patterns are presented. The void fractions are determined based on image analysis. New correlation for two-phase frictional multiplier is also proposed for practical applications.  相似文献   
8.
Three flow injection (FI) systems were investigated for the determination of trace iron in beer: an FI-in-valve column-flame atomic absorption spectrophotometry (FI-FAAS) system, a spectrophotometric FI system with a column placed at the detection point, and an FI-spectrophotometric system with bead injection (FI-BI). Cationic exchange resin Dowex 50W X8 and iminodiacetate chelating resin, Chelex-100, were employed for the FI-spectrophotometric and FI-FAAS systems, respectively. The FI-in-valve column, packed with the resin, enhances the FAAS performance. The spectrophotometric FI system with a column (packed with Chelex-100) placed at the detection point (in a cell holder of a spectrophotometer) is based on the formation of iron (II)–1,10-phenanthroline complex sorbed onto the resin. No eluent has been found to be suitable. The FI-BI for renewable microcolumn has been proven to be an alternative. The FI-FAAS and FI-BI procedures provide online sample preseparation and preconcentration for the determination of iron in beer. Both are simple, rapid, and economical. The procedures also involve sample preparation (decarbonation and suppression of tannin interference by adding ascorbic acid) and standard addition. The results obtained by FI-FAAS and FI-BI agree with those of AOAC spectrophotometric method.  相似文献   
9.
Nanofluid is an innovative heat transfer fluid with superior potential for enhancing the heat transfer performance of conventional fluids. Many attempts have been made to investigate its thermal conductivity and viscosity, which are important thermophysical properties. No definitive agreements have emerged, however, about these properties. This article reports the thermal conductivity and dynamic viscosity of nanofluids experimentally. TiO2 nanoparticles dispersed in water with volume concentration of 0.2–2 vol.% are used in the present study. A transient hot-wire apparatus is used for measuring the thermal conductivity of nanofluids whereas the Bohlin rotational rheometer (Malvern Instrument) is used to measure the viscosity of nanofluids. The data are collected for temperatures ranging from 15 °C to 35 °C. The results show that the measured viscosity and thermal conductivity of nanofluids increased as the particle concentrations increased and are higher than the values of the base liquids. Furthermore, thermal conductivity of nanofluids increased with increasing nanofluid temperatures and, conversely, the viscosity of nanofluids decreased with increasing temperature of nanofluids. Moreover, the measured thermal conductivity and viscosity of nanofluids are quite different from the predicted values from the existing correlations and the data reported by other researchers. Finally, new thermophysical correlations are proposed for predicting the thermal conductivity and viscosity of nanofluids.  相似文献   
10.
Li1−x Ni1+x O2 was prepared by the thermal-assisted precipitation process of LiOH · H2O and Ni(CH3COO)2 · 4H2O at a pH of 6–13 followed by the high temperature calcination for a variety of prolonged times. Phases, morphologies and constituents were characterized using an x-ray diffractometer (XRD), a scanning electron microscope (SEM), an energy dispersive x-ray (EDX) analyzer an atomic absorption spectrophotometer (AAS) and titration. Maximum [I(003)/I(104)] and minimum [I(006+102)/I(101)] intensity ratios were used to determine the preparation conditions. In addition, possible formation reactions of the precursors and calcined products were proposed. The article was submitted by the authors in English.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号