首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   156篇
  免费   8篇
化学   130篇
力学   4篇
数学   13篇
物理学   17篇
  2023年   1篇
  2022年   9篇
  2021年   5篇
  2020年   4篇
  2019年   2篇
  2017年   4篇
  2016年   4篇
  2015年   7篇
  2014年   4篇
  2013年   7篇
  2012年   8篇
  2011年   13篇
  2010年   3篇
  2009年   7篇
  2008年   11篇
  2007年   9篇
  2006年   15篇
  2005年   11篇
  2004年   10篇
  2003年   4篇
  2002年   9篇
  2001年   4篇
  2000年   3篇
  1998年   2篇
  1997年   2篇
  1994年   2篇
  1991年   2篇
  1985年   1篇
  1982年   1篇
排序方式: 共有164条查询结果,搜索用时 31 毫秒
1.
A sequential injection methodology for the spectrophotometric determination of calcium, magnesium and alkalinity in water samples is proposed. A single manifold is used for the determination of the three analytes, and the same protocol sequence allows the sequential determination of calcium and magnesium (the sum corresponds to the water hardness). The determination of both metals is based on their reaction with cresolphtalein complexone; mutual interference is minimized by using 8-hydroxyquinoline for the determination of calcium and ethylene glycol-bis(beta-aminoethyl ether)-N,N,N',N'-tetraacetic acid (EGTA) for the determination of magnesium. Alkalinity determination is based on a reaction with acetic acid, and corresponding color change of Bromcresol Green. Working ranges of 0.5 - 5 mg dm(-3) for Ca, 0.5 - 10 mg dm(-3) for Mg, and 10 - 100 mg HCO3- dm(-3), for alkalinity have been achieved. The results for water samples were comparable to those of the reference methods and to a certified reference water sample. RSDs lower than 5% were obtained, a low reagent consumption and a reduced volume of effluent have been accomplished. The determination rate for calcium and magnesium is 80 h(-1), corresponding to 40 h(-1) per element, while 65 determinations of alkalinity per hour could be carried out.  相似文献   
2.
Using voltage-time responses and cyclic voltammetry, the initial stages of anodizing of Al–2.1 at.% Ag and Al–4 at.% Ag alloys are shown to depend upon the heat treatment of the alloys and the pre-treatment of the alloy surfaces. Chemical polishing of solution-treated alloys leads to relatively uniform anodic oxidation on a relatively smooth alloy surface, in the absence of significant effects of coarse, silver-rich intermetallics. In contrast, losses of current to oxygen generation arise for the roughened alloy surface from mechanical polishing. With ageing, secondary reactions at the relatively silver-rich intermetallics are more prevalent, although the effects on the voltage-time response depend upon the balance between processes occurring on the matrix and intermetallic regions, including film growth, oxygen generation within the anodic film, film damage due to release of oxygen, dissolution of silver species and re-growth of damaged film.  相似文献   
3.
Determination of ambroxol in an automated multi-pumping pulsed flow system.   总被引:3,自引:0,他引:3  
A new flow methodology exploiting the multi-pumping approach was developed for the spectrophotometric determination of ambroxol hydrochloride in pharmaceutical preparations. The flow manifold was implemented by using, exclusively, multiple solenoid-actuated micro-pumps, which acted simultaneously as sample insertion, solutions propelling and reagents commutation units. Linear calibration plots were obtained over an ambroxol concentration ranging from 10 to 200 mg l(-1) (r.s.d. < 0.5%, n = 15) and a sampling rate of about 60 samples per hour (flow rate = 1.92 ml min(-1), sample volume = 80 microl).  相似文献   
4.
Mössbauer spectroscopy was used to follow the aging of ferrihydrite with different amounts of acetate, to achieve more crystalline products. Mössbauer spectra of fresh samples did not show any magnetic components. After two years aging, the solids presented crystalline fractions. Hematite formation was inhibited as acetate content increased in solids. For an acetate/iron molar ratio equal to 0.63 goethite was formed instead of hematite. X-ray diffraction confirmed these results. This work shows that synthetic samples can be used for elucidating the anti-hematitic effect of organic matter already detected in soils.  相似文献   
5.
Lima MJ  Tóth IV  Rangel AO 《Talanta》2005,68(2):207-213
A sequential injection system based on the ABTS (2,2′-azino-bis-(3-ethylbenzothiazoline-6-sulphonic-acid) methodology was developed. The proposed method, incorporating a mixing chamber in the side port of the selection valve, was evaluated to measure the total antioxidant activity of several beverages and foods.The ABTS+ is generated by oxidation of ABTS with potassium persulfate and is reduced in presence of hydrogen-donating antioxidants converting into a colourless product. The applicability of the developed method was tested by measurement of the antioxidant activity of pure compounds as well as by analysing complex food and beverage samples. The antioxidant activity was presented as l(+) ascorbic acid equivalence. The values obtained by this methodology were not significantly different from the results obtained by the original spectrophotometric ABTS assay. For most of the studied antioxidants, antioxidant activity varied with pH and dilution. The proposed SIA system is suitable for screening direct or diluted total antioxidant activity of pure compounds or food samples.  相似文献   
6.
A flow injection system for the automatic determination of total phosphorus in beer is described. The developed manifold uses a two-stage photooxidation/thermal digestion procedure together with oxidizing and hydrolyzing reagents to convert all forms of phosphorus compounds to orthophosphate. Polyphosphates are hydrolyzed by acid and heat, and organo-phosphates are digested by UV-catalyzed peroxodisulfate oxidation. The orthophosphate formed is then spectrophotometrically determined by the phosphomolybdenum blue reaction, using stannous chloride as reducing agent. The results obtained for a set of 19 beer samples (with concentrations from 120 to 735 mg P/L) were in good agreement with the reference method, the maximum relative deviation found being 4.7%. Relative standard deviations for ten consecutive determinations were lower than 1.5%, and a detection limit of 1 mg P/L was achieved.  相似文献   
7.
The chiral compounds (R)‐ and (S)‐1‐benzoyl‐2,3,5,6‐tetrahydro‐3‐methyl‐2‐(1‐methylethyl)pyrimidin‐4(1H)‐one ((R)‐ and (S)‐ 1 ), derived from (R)‐ and (S)‐asparagine, respectively, were used as convenient starting materials for the preparation of the enantiomerically pure α‐alkylated (alkyl=Me, Et, Bn) α,β‐diamino acids (R)‐ and (S)‐ 11 – 13 . The chiral lithium enolates of (R)‐ and (S)‐ 1 were first alkylated, and the resulting diasteroisomeric products 5 – 7 were aminated with ‘di(tert‐butyl) azodicarboxylate’ (DBAD), giving rise to the diastereoisomerically pure (≥98%) compounds 8 – 10 . The target compounds (R)‐ and (S)‐ 11 – 13 could then be obtained in good yields and high purities by a hydrolysis/hydrogenolysis/hydrolysis sequence.  相似文献   
8.
 A flow injection system was developed for the sequential determination of total nitrogen and phosphorus in digests of vegetables using potentiometric and spectrophotometric detection systems, respectively. A tubular ammonium selective electrode with a sensor system composed of nonactin/monactin in tris(2-ethylhexyl) phosphate was used. The selectivity limitations of this electrode were overcome by the inclusion of a gas-diffusion unit in the system that separated ammonium from the rest of the sample matrix and allowed the determination of total nitrogen and phosphorus by the partition of the sample plug between two streams. The results obtained with the developed FIA system were in good agreement with those of the reference methods. Sampling rates from 40 to 60 samples per hour and relative standard deviations below 3.5% were achieved. Received: 17 October 1996/Revised: 21 November 1996/Accepted: 27 November 1996  相似文献   
9.
 A flow injection system was developed for the sequential determination of total nitrogen and phosphorus in digests of vegetables using potentiometric and spectrophotometric detection systems, respectively. A tubular ammonium selective electrode with a sensor system composed of nonactin/monactin in tris(2-ethylhexyl) phosphate was used. The selectivity limitations of this electrode were overcome by the inclusion of a gas-diffusion unit in the system that separated ammonium from the rest of the sample matrix and allowed the determination of total nitrogen and phosphorus by the partition of the sample plug between two streams. The results obtained with the developed FIA system were in good agreement with those of the reference methods. Sampling rates from 40 to 60 samples per hour and relative standard deviations below 3.5% were achieved. Received: 17 October 1996/Revised: 21 November 1996/Accepted: 27 November 1996  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号