首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   33篇
  免费   0篇
  国内免费   1篇
化学   31篇
力学   1篇
物理学   2篇
  2021年   2篇
  2020年   1篇
  2016年   2篇
  2015年   1篇
  2014年   1篇
  2013年   2篇
  2012年   2篇
  2011年   4篇
  2010年   2篇
  2009年   1篇
  2008年   3篇
  2007年   1篇
  2006年   2篇
  2005年   1篇
  2004年   2篇
  2002年   4篇
  1998年   1篇
  1995年   1篇
  1992年   1篇
排序方式: 共有34条查询结果,搜索用时 404 毫秒
1.
THREEPROM  Jirasak  SOM-AUM  Waraporn  林金明 《中国化学》2006,24(12):1747-1753
A new separation system of capillary electrophoresis for the simultaneous determination of metals by using ethylenediamine tetraacetic acid (EDTA) as complexing agent and employing vancomycin as complex selector was described. The Z-shape cell capillary electrophoresis was used to enhance the sensitivity for the determination of the complexes of Cu(Ⅱ), Ni(Ⅱ), Co(Ⅱ) and Fe(Ⅲ) with EDTA. The partial filling method (co-current mode) was used in order to increase the selectivity of the electrophoretic method, meanwhile vancomycin was not present at the detector path during the detection of metal-EDTA complexes. The vancomycin concentration, phosphate concentration and pH of the buffer strongly influenced mobility, resolution and selectivity of the studied analytes. Under the optimal condition, the relative standard deviations (n=5) of the migration time and the peak area were less than 3.14% and 7.35%, respectively. Application of the Z-shape cell capillary electrophoresis method with UV detection and vancomycin loading led to the reliable determination of these metal ions in tap water and the recoveries were 97%-101%. The detection limits based on a signal to noise ratio of 3 : 1 were found in the range of 2-10 μg·L^-1.  相似文献   
2.
Summary Piperidinomethyl-2-naphthol forms inclusion complexes with -cyclodextrin with an equilibrium constant of 265M –1 in aqueous solution. The proton transfer equilibrium between the neutral and the zwitterionic form is strongly influenced by the association.
Der Einfluß der Komplexierung mit -Cyclodextrin auf das Protontransfer-Gleichgewicht in Piperidino-2-naphthol (Kurze Mitt.)
Zusammenfassung Piperidinomethyl-2-naphthol bildet Einschlußkomplexe mit -Cyclodextrin mit einer Gleichgewichtskonstante von 265M –1. Das Protontransfer-Gleichgewicht zwischen neutraler Form und zwitterionischer Struktur wird durch diese Assoziation stark beeinflußt.
  相似文献   
3.
This work duly investigates the recovery of Pd (II) chlorocomplexes from industrial wastewater. Chemical structures and thermodynamic stabilities of the complex formed are evaluated via density functional theory (DFT). By applying synergistic solutions of thiourea mixed with hydrochloric acid (HCl), the stripping reaction of Pd (II) in the loaded Aliquat 336 occurs and Pd (II) chlorocomplexes coordinated thiourea ligands are formed, thus 80.19% of Pd (II) chlorocomplexes can be recovered. The aim of this study is to gain a better understanding of the stripping mechanisms and the structure of the complexes formed via the synergistic system. Such an understanding is still limited since little research has been conducted in this field. Owing to their molecular geometry, ligand coordination and donor groups play a vital role in the reactivity of palladium (II) complex. Quantum models have been developed to evaluate the chemical structure and thermodynamics stability of ((NH2)2CS·PdCl2) namely: (i) DFT with B3LYP/6-31g(d,p) and MP2/6-31g(d,p) basis set, (ii) MP2 with cc-pVTZ basis set and (iii) CCSD(T)/cc-pVTZ. Results demonstrate that the highest geometric stability exhibited is the structure of Pd-S bonding with 180° Cl-Pd-Cl. The distance (r) and angle (a) of the selected geometrical parameters for (NH2)2CS·PdCl2 complex are reported. Additionally, FTIR and UV–vis spectroscopies have been conducted to analyze the sampling solutions. Further, the calculated vibrational frequencies and experimental spectroscopic results show good agreement with the optimized geometry.  相似文献   
4.
Asiaticoside (AS), the major active component of Centella asiatica (L.) Urban, is used as a memory enhancer and for wound healing. We have successfully prepared monoclonal antibodies (MAbs) against AS, and developed an enzyme-linked immunosorbent assay (ELISA) system for its determination. AS was conjugated to the carrier protein bovine serum albumin (BSA), which acted as an immunogen. In order to confirm its immunogenicity, the ratio of hapten in the AS-BSA conjugate was determined by matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS). After immunization, hybridomas secreting MAbs against AS were produced by fusing splenocytes with the mouse myeloma cell line, SP2/0-Ag14. After the screening, anti-asiaticoside MAb 2B4 was obtained. Weak cross-reactivities occurred with madecassoside (7.08%), but no cross-reactivities were observed with other related triterpenoid glycosides (<0.01%). The assay was suitable for quantitating AS in the range of 0.78 to 50 μg mL(-1). A good correlation of AS concentrations in crude extracts of C. asiatica between ELISA and HPLC methods was obtained (r(2) = 0.999). The contents of AS in various cultivated C. asiatica samples were assayed by the newly established ELISA. The recovery rates of AS in the samples were in the range of 95-103% with coefficients of variation of <10%. The intra- and inter-assay variations were 3.9 and 4.5%, respectively. The ELISA method described should prove useful as an analytical tool for quality control and standardization of medicinal plants and pharmaceutical products containing AS.  相似文献   
5.
There have been reports of fake artesunate (ART), which has led to deaths from untreated malaria in South East Asia. To rapidly screen for fake and adulterated ART products in the drug market, a lateral flow immunoassay (LFIA) based on a colloidal gold–monoclonal antibody probe for detection of ART within samples was developed. With this method, the calibration curve for ART was determined by the intensity ratio of the test and control bands at various ART concentrations. The linearity range was 12.5–200 μg/ml of ART. Samples were tested by the developed LFIA and can be calculated for ART contents. The levels of ART in the samples were also confirmed by enzyme-linked immunosorbent assay. The results of the two methods were in good conformance. The proposed LFIA was demonstrated to be a simple and rapid analytical method for detecting ART in the pharmaceutical formulation.  相似文献   
6.
For the copolymerization of ethylene with propylene or a higher α‐olefin, using Et[Ind]2ZrCl2 metallocene catalyst, modification of silica with silicon tetrachloride prior to MAO adsorption can increase the activity, which is more pronounced for ethylene/1‐hexene copolymerization at higher pressure and temperature. The molecular weight of the copolymer produced was lower and the polydispersity tends to be decreased. No significant effect of SiCl4 addition on the microstructure and the chemical composition distribution of the copolymer produced was observed.  相似文献   
7.
The heating process of dielectric materials by microwave with rectangular wave guide has been investigated experimentally. This experiment is operated in the TE10-dominated mode at a frequency of 2.45 GHz. It was performed for two dielectric materials, water layer and saturated porous medium. In this work, the microwave powers level, a type of dielectric materials, dimensions and positions of dielectric material on the microwave power absorb and average temperature within dielectric materials were examined in details. The results show that the locations of sample have greater effects than the other parameters. The analyses from this research serve as essential fundamentals to development of mathematic models of heat and mass transfer phenomena.  相似文献   
8.
A simple, rapid and sensitive method for the determination of chromium(III) and total chromium using the simple dual T channels on glass chip with negative pressure pumping system and chemiluminescence (CL) detection is presented. The CL reaction was based on luminol oxidation by hydrogen peroxide in basic aqueous solution catalyzed by chromium(III). Total chromium in form of chromium(III) was achieved after chromium(VI) was completely reduced by acidic sodium hydrogen sulfite. Total chromium could then be determined with the same strategy as the chromium(III). The CL reagent was composed of 1.0 × 10−4 mol/L luminol, 1.0 × 10−2 mol/L hydrogen peroxide and 0.10 mol/L sodium bromide in 0.050 mol/L carbonate buffer (pH 11.00). The 1.0 × 10−2 mol/L ethylenediaminetetraacetic acid was added into the sample solution in order to improve the selectivity. Chromium(III) could be detected at a notably concentration of 1.6 × 10−16 mol/L and a linear calibration curve was obtained from 1.0 × 10−15 to 1.0 × 10−13 mol/L. The sample and CL reagent consumption were only 15 and 20 μL, respectively. The analysis time was less than 1 min per sample with the precision (%R.S.D.) was 4.7%. The proposed method has been applied successfully to the analysis of river water, mineral waters, drinking waters and tap water. Its performance was verified by the analysis of certified total chromium-reference materials and by recovery measurement on spiked synthetic seawater sample.  相似文献   
9.
Based on the belief that structural optimization methods, producing structures more closely to the experimental ones, should give better, i.e. more relevant, steric fields and hence more predictive CoMFA models, comparative molecular field analyses of artemisinin derivatives were performed based on semiempirical AM1 and HF/3-21G optimized geometries. Using these optimized geometries, the CoMFA results derived from the HF/3-21G method are found to be usually but not drastically better than those from AM1. Additional calculations were performed to investigate the electrostatic field difference using the Gasteiger and Marsili charges, the electrostatic potential fit charges at the AM1 level, and the natural population analysis charges at the HF/3-21G level of theory. For the HF/3-21G optimized structures no difference in predictability was observed, whereas for AM1 optimized structures such differences were found. Interestingly, if ionic compounds are omitted, differences between the various HF/3-21G optimized structure models using these electrostatic fields were found.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号