首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   5篇
  免费   0篇
化学   5篇
  2020年   1篇
  2016年   1篇
  2015年   1篇
  2012年   2篇
排序方式: 共有5条查询结果,搜索用时 0 毫秒
1
1.
Paper-based microfluidic devices (μPADs) are capable of achieving rapid quantitative measurements of a variety of analytes inexpensively. μPADs rely on patterning hydrophilic-hydrophobic regions on a sheet of paper in order to create capillary channels within impermeable fluidic brakes on the paper. Here, we present a novel, highly flexible and low-cost fabrication method using a desktop digital craft plotter/cutter and technical drawing pens with tip size of 0.5 mm. The pens were used with either commercial black permanent ink for drawing fluidic brakes, or with specialty in-house formulated aqueous inks. With the permanent marker ink it was possible to create barriers on paper rapidly and in a variety of designs in a highly flexible manner. For instance, a design featuring eight reservoirs can be produced within 10 s for each μPAD with a consistent line width of brakes (%RSD < 1.5). Further, we investigated the optimal viscosity range of in-house formulated inks controlled with additions of poly(ethylene glycol). The viscosity was measured by capillary electrophoresis and the optimal viscosity was in the range of ∼3–6 mPa s. A functional test of these μPADs was conducted by the screening of antioxidant activity. Colorimetric measurements of flavonoid, phenolic compounds and DPPH free radical scavenging activity were carried out on μPADs. The results can be detected by the naked eye and simply quantified by using a camera phone and image analysis software. The fabrication method using technical drawing pens provides flexibility in the use of in-house formulated inks, short fabrication time, simplicity and low cost.  相似文献   
2.
Trends towards portable analytical instrumentation of the last decades have not been equally reflected in developments of portable liquid chromatography (LC) instrumentation for rapid on-site measurements. A miniaturised medium pressure capillary LC (MPLC) system with gradient elution capability has been designed based on a flexible modular microfluidic system using primarily off-the-shelf low cost components to ensure wide accessibility to other analysts. The microfluidic platform was assembled on a breadboard and contained microsyringe pumps and switch valves, complemented with an injection valve and on-capillary detectors, all controlled by a PC. Four miniaturised microsyringe pumps, with 5, 20 and 100 μL syringe volume options, formed the basis of the pumping system. Two pairs of pumps were used for each mobile phase to create gradient elution capability. The two microsyringe pumps in each pairs were linked by two electrically operated microfluidic switching valves and both pairs of pumps were connected through a zero void volume cross-connector, thus providing a low hold-up volume for gradient formation. Sample was injected by a 20 nL nano-LC sampling valve, directly connected to a 18 cm long 100 μm i.d. Chromolith CapRod RP-18 monolithic capillary column. On-capillary LED-based UV–vis photometric detection was conducted through a piece of equal diameter fused silica capillary connected after the column. The performance of the portable LC system was evaluated theoretically and experimentally, including the maximum operating pressure, gradient mixing performance, and the performance of the detectors. The 5 μL microsyringe pump offered the best performance, with typical maximum operating pressures up to 11.4 ± 0.4 MPa (water) and gradient pumping repeatability of between 4 and 9% for gradients between 0.10% s−1 and 0.33% s−1. Test analytes of charged and uncharged dyes and pharmaceuticals of varying hydrophobicity showed typical RSD values of 0.7–1.4% and 3.3–4.8% in isocratic mode and 1.2–4.6% and 3.2–6.4% in gradient mode, respectively for retention time and peak area repeatability.  相似文献   
3.
Exosome quantification is important for estimation of informative messengers (e.g., proteins, lipids, RNA, etc.) involving physiological and pathological effects. This work aimed to develop a simple and rapid distance-based paper portable device using exosome-capture vesicles (polydiacetylene conjugated with antiCD81) for exosome quantification in cell cultures. This novel concept relied on distinct aggregation of exosomes and exosome-capture vesicles leading to different solvent migration. Distances of the migration were used as signal readouts, which could be detected by naked eye. PDA-antiCD81 as exosome-capture vesicles were optimized (e.g., size, reaction ratio, and concentration) and the paper designs were investigated (e.g., diameter of sample reservoir and lamination layer) to enhance the solvent stop-flow effects. Finally, exosome screening on three cell culture samples (COLO1, MDA-MB-231, and HuR-KO1 subclone) was demonstrated. The method could linearly measure exosome concentrations in correlation with solvent migration distances in the range of 106–1010 particles/mL (R2 > 0.98) from the cell culture samples. The exosome concentration measurements by the developed device were independently assessed by nanoparticle tracking analysis. Results demonstrated no statistically significant difference (p > 0.05) by t-test. This low-cost and rapid device allows a portable platform for exosome quantification without the requirement of expensive equipment and expertise of operation. The developed device could potentially be useful for quantification of other biomarker-related extracellular vesicles.  相似文献   
4.
A capillary zone electrophoretic method using UV detection is developed for the analysis of four biological active pyridines [i.e., nicotine (NIC), cotinine (COT), nicotinic acid (NA), and nicotinamide (NM)]. The separation of the pyridines is achieved in 25 mM sodium dihydrogen phosphate (pH 2.1) using a fused-silica capillary with an effective length of 56 cm and an inner diameter of 50 μm (extended light path), hydrodynamic injection at 50 mbar for 10 s, a temperature of 25°C, applied voltage of 30 kV, and UV detection at 260 nm. These conditions provide baseline separation of all the analytes [resolution (R(s)) > 3.6] in 9.4 min with good linearity (r(2) > 0.998, in ranges of 50-600 μg/mL for NIC, 8-160 μg/mL for NM, and 10-200 μg/mL for COT and NA), precision (relative standard deviation <2.04%), recovery (96.4-101.6%), limits of detection (<3.0 μg/mL), and quantitation (<10 μg/mL). The method is robust upon the alterations of pH of BGE, separating voltage, and injection time [the RSDs of the relative migration time (migration time of the analyte/migration time of the internal standard) and resolution <3.26%]. The method is efficient, reliable, and simple for the routine analysis of NIC, NA, and NM in various products such as gum and tablets and can be applied to determine COT in thermal degradation of NIC gum.  相似文献   
5.
Rapid detection of microorganisms by alternative methods is desirable. Electromigration separation methods have the capability to separate microorganisms according to their charge and size and laser-induced fluorescence (LIF) detection have single-cell detection capability. In this work, a new combined separation and detection scheme was introduced using chip-based capillary electrophoresis (chip-CE) platform with LIF detection. Three microorganisms Escherichia coli, Staphylococcus aureus, and Candida albicans were selected as representatives of Gram-positive bacteria, Gram-negative bacteria, and fungi. While their cells carry an overall negative charge in neutral to alkaline pH, staining them with nile blue (NB) provided highly sensitive LIF detection with excitation and emission wavelengths at 635 nm and 685 nm, respectively, and at the same time, the overall charge was converted to positive. Electrolyte pH and concentration of polyethylene oxide (PEO) significantly affected the resolution of the microorganisms. Their optimal separation in the 14 mm separation channel was achieved in less than 30 s (R(s) > 5.3) in an electrolyte consisting of 3.94 mM Tris, 0.56 mM boric acid, 0.013 mM ethylenediaminetetraacetic acid disodium salt dihydrate (pH 10.5), and 0.025% PEO, with injection/separation voltages of +1000/+1000 V. The separation mechanism is likely employing contributions to the overall cationic charge from both the prevalently anionic membrane proteins and the cationic NB. Importantly, the resulting cationic NB-stained cells exhibited excellent separation selectivity and efficiency of ~38000 theoretical plates for rapid separations within 30-40 s. The results indicate the potential of chip-CE for microbial analysis, which offers separations of a wide range of species with high efficiency, sensitivity, and throughput.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号