排序方式: 共有4条查询结果,搜索用时 15 毫秒
1
1.
A variety of disubstituted (double-comb) polysiloxane polymers have been prepared containing linear, branched, and cyclic oligoethyleneoxide units, –(OCH2CH2)n–, in the side chains and as part of the siloxane backbone. Copolymers, using mixtures of linear ethylene oxide side chains, were also synthesized. These polymers were doped with LiN(SO2CF3)2 (LiTFSI, 1) and conductivities of the polymer-salt complexes were determined as a function of temperature and doping level. The maximum conductivity of these polymers at 25 ° C was 2.99 ×10–4, for a copolymer containing equimolar amounts of side chains with n = 5 and 6. 相似文献
2.
Fabrication of a Single Layer and Bilayer Potentiometric Biosensors for Penicillin by Galvanostatic Entrapment of Penicillinase into Polypyrrole Films 总被引:1,自引:0,他引:1
下载免费PDF全文
![点击此处可从《Electroanalysis》网站下载免费的PDF全文](/ch/ext_images/free.gif)
A single layer and bilayer potentiometric biosensors for the detection of penicillin have been developed. The favourable conditions that were established for the polypyrrole‐penicillinase ((PPy‐P’nase) single layer biosensor were 0.03 M pyrrole, 50 U/mL P’nase, 0.01 M penicillin, applied current density of 0.9 mA/cm2 and a polymerisation time of 40 s. The optimum conditions for the formation of the outer layer of the bilayer were: (a) 0.1 M Py, 19 U/mL P’nase, 0.01 M pen, current density of 0.9 mA/cm2 and a polymerisation time of 40 s. The minimum detectable penicillin concentration with the bilayer potentiometric biosensor was 0.3 µM and the linear concentration range was 7.5–146 µM. The average percentage recovery of penicillin that was found in amoxycillin 500 mg was 113±24 %. The determination of penicillin in milk was fraught with problems of non‐specific binding of penicillin to the milk. 相似文献
3.
G. Mechtersheimer G. Büche U. Klein W. Kluge H. Matthäy D. Münchmeyer A. Moline 《Physics letters. [Part B]》1978,73(2):115-118
Energy spectra of charged particles (protons, deuterons, tritons, 3He, 4He and lithium nuclei) emitted after the absorption of stopped negative pions in a thin polyethylene target of 20 mg/cm2 have been measured with high accuracy from the experimental threshold energy (of about 0.5 MeV) up to the kinematical limit of about 100 MeV. 相似文献
4.
U. Klein G. Büche W. Kluge H. Matthäy G. Mechtersheimer A. Moline 《Nuclear Physics A》1979,329(3):339-353
Energy spectra of neutrons emitted following the absorption of stopped negative pions in carbon, nitrogen and oxygen were measured from about 2.5 MeV up to the kinematical limit. The experiments were carried out at the biomedical pion channel πE3 of the Swiss Institute for Nuclear Research (SIN). The evaporation part of the spectra was extrapolated to zero energy using the formula of Le Couteur. Various parameters like mean neutron energies and neutron multiplicities are given. The data are compared with experimental data obtained by other authors and with results of intranuclear cascade calculations. 相似文献
1