首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   12篇
  免费   2篇
化学   14篇
  2022年   1篇
  2016年   2篇
  2015年   2篇
  2014年   1篇
  2013年   1篇
  2012年   1篇
  2006年   1篇
  2003年   1篇
  2000年   1篇
  1993年   1篇
  1981年   2篇
排序方式: 共有14条查询结果,搜索用时 218 毫秒
1.
Abstract— 3, 7-Dimethyl-2, 4, 6, 8, 10-dodecapentaenal was synthesized for reconstitution of the retinochrome analog. Its opsin shift was 1000 cm 1 smaller than that of native retinochrome, whose chromophore contains the same number of double bonds. The conformational change from 6-s-trans to 6-s-cis , as figured in a retinal molecule, plays an important role in the formation of the retinochrome analog, based on the estimation of opsin shifts for retinal analogs locked in the 6-s conformation. Thus the conformation of the 6–7 single bond in the native retinochrome was suggested to be 6 -cis . Analysis of the circular dichroic spectra of retinochrome analogs revealed that the 6-s conformation is independent of the appearance of the β-band. The stereoselectivity in the photoisomerization of the retinal analogs by a retinochrome template depends on the hydrophobic binding in the region of the β-ionone ring.  相似文献   
2.
The effects of Soto's 'beta-sheet breaker peptide' and its polymer on PrPSc formation in ScN2a cells were investigated. Surface plasmon resonance study indicated that direct binding between PrP(81-145) and the 'beta-sheet breaker peptide' is not specific and may not play a major role in the inhibition of PrPSc formation.  相似文献   
3.
Sakaguchi  Yohei  Kinumi  Tomoya  Takatsu  Akiko 《Chromatographia》2022,85(4):343-352
Chromatographia - Recently, we developed a sensitive and accurate quantification method for short-chain peptides using dual functional-group derivatization. Sensitive and accurate quantification...  相似文献   
4.
A certified reference material (CRM) is a higher-order calibration material used to enable a traceable analysis. This paper describes the development of a C-peptide CRM (NMIJ CRM 6901-a) by the National Metrology Institute of Japan using two independent methods for amino acid analysis based on isotope-dilution mass spectrometry. C-peptide is a 31-mer peptide that is utilized for the evaluation of β-cell function in the pancreas in clinical testing. This CRM is a lyophilized synthetic peptide having the human C-peptide sequence, and contains deamidated and pyroglutamylated forms of C-peptide. By adding water (1.00 ± 0.01) g into the vial containing the CRM, the C-peptide solution in 10 mM phosphate buffer saline (pH 6.6) is reconstituted. We assigned two certified values that represent the concentrations of total C-peptide (mixture of C-peptide, deamidated C-peptide, and pyroglutamylated C-peptide) and C-peptide. The certified concentration of total C-peptide was determined by two amino acid analyses using pre-column derivatization liquid chromatography-mass spectrometry and hydrophilic chromatography-mass spectrometry following acid hydrolysis. The certified concentration of C-peptide was determined by multiplying the concentration of total C-peptide by the ratio of the relative area of C-peptide to that of the total C-peptide measured by liquid chromatography. The certified value of C-peptide (80.7 ± 5.0) mg/L represents the concentration of the specific entity of C-peptide; on the other hand, the certified value of total C-peptide, (81.7 ± 5.1) mg/L can be used for analyses that does not differentiate deamidated and pyroglutamylated C-peptide from C-peptide itself, such as amino acid analyses and immunochemical assays.  相似文献   
5.
6.
Fine metal or metal oxide powder as an alternative to conventional organic matrices in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been utilized successfully for lower molecular mass analytes, poly(ethylene glycol) 200 (PEG 200) and methyl stearate. Eleven kinds of particle, Al, Mn, Mo, Si, Sn, SnO2, TiO2, W, WO3, Zn and ZnO, were evaluated. The analyte was mixed with a metal or metal oxide powder (inorganic matrix) with particle diameter of tens of micrometers and liquid dispersant, followed by application to the sample target. Using a commercial MALDI-TOFMS instrument equipped with an internal 337 nm pulsed nitrogen laser, the analytes, PEG 200 and methyl stearate, were ionized as the alkali metal ion adducted molecules [M+Na]+ or [M+K]+ when the inorganic matrices Mn, Mo, Si, Sn, TiO2, W, WO3, Zn or ZnO were used. In the case of an Al matrix, PEG 200 was ionized as [M+K]+, whereas methyl stearate was ionized as [M+H]+ and [M+Al]+. These particles have potential as the matrix for MALDI. During our examination, however, only SnO2 particles did not ionize either PEG 200 or methyl stearate. Based on our protocol, when TiO2 powder was suspended with liquid paraffin, PEG 200 and methyl stearate gave their MALDI-TOF mass spectra with the lowest background noise and highest intensity. TiO2 powder seemed to be a broad potential matrix for low molecular mass polar or non-polar analytes. The results suggested that bulk particles caused rapid heating/vaporization processes and ionized analyte molecules under irradiation with a pulsed UV laser. The present method can be readily applied to obtain the low background noise MALDI-TOF mass spectra of small-sized compounds.  相似文献   
7.
Stable isotope‐coding coupled with mass spectrometry is a popular method for quantitative proteomics and peptide quantification. However, the efficiency of the derivatization reaction at a particular functional group, especially in complex structures, can affect accuracy. Here, we present a dual functional‐group derivatization of bioactive peptides followed by micro liquid chromatography‐tandem mass spectrometry (LC‐MS/MS). By separating the sensitivity‐enhancement and isotope‐coding derivatization reactions, suitable chemistries can be chosen. The peptide amino groups were reductively alkylated with acetaldehyde or acetaldehyde‐d4 to afford N‐alkylated products with different masses. This process is simple, quick and high‐yield, and accurate comparative analysis can be achieved for the mass‐differentiated peptides. Then, the carboxyl groups were derivatized with 1‐(2‐pyrimidinyl)piperazine to increase MS/MS sensitivity. Angiotensins I–IV, bradykinin and neurotensin were analyzed after online solid phase extraction by micro LC‐MS/MS. In all instances, a greater than 17‐fold increase in sensitivity was achieved, compared with the analyses of the underivatized peptides. Furthermore, the values obtained from the present method were in agreement with the result from isotope dilution quantification using isotopically labeled angiotensin I [Asp‐Arg‐(Val‐d8)‐Tyr‐Ile‐His‐Pro‐(Phe‐d8)‐His‐Leu]. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   
8.
Viologen-linked water-soluble porphyrins with different methylene chain lengths between porphyrin and viologen were synthesized. These compounds were applied to photoinduced hydrogen evolution in a system containing NADPH, viologen-linked porphyrin, and hydrogenase under steady-state irradiation.  相似文献   
9.
A novel method of amino acid analysis using derivatization of multiple functional groups (amino, carboxyl, and phenolic hydroxyl groups) was applied to measure glycated amino acids in order to quantify glycated peptides and evaluate the degree of glycation of peptide. Amino and carboxyl groups of amino acids were derivatized with 1‐bromobutane so that the hydrophobicities and basicities of the amino acids, including glycated amino acids, were improved. These derivatized amino acids could be detected with high sensitivity using LC‐MS/MS. In this study, 1‐deoxyfructosyl‐VHLTPE and VHLTPE, which are N‐terminal peptides of the β‐chains of hemoglobin, were selected as target compounds. After reducing the peptide sample solution with sodium borohydride, the obtained peptides were hydrolyzed with hydrochloric acid. The released amino acids were then derivatized with 1‐bromobutane and analyzed with LC‐MS/MS. The derivatized amino acids, including glycated amino acids, could be separated using an octadecyl silylated silica column and good sharp peaks were detected. We show a confirmatory experiment that the proposed method can be applied to evaluate the degree of glycation of peptides, using mixtures of glycated and non‐glycated peptide. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   
10.
The structure of concanamycin A was proposed on the basis of PMR analyses of concanamycin A and its ozonolysis products.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号