排序方式: 共有46条查询结果,搜索用时 15 毫秒
1.
Ibrahim Isildak Murat Yolcu Omer Isildak Nadir Demirel Giray Topal Halil Hosgoren 《Mikrochimica acta》2004,144(1-3):177-181
Two diaza-crown ether compounds were synthesized and evaluated as Ag+-selective carriers in polyvinylchloride (PVC) membrane electrodes of solid-state type. The all-solid-state PVC membrane electrode based on N,N-Dibenzyl-dibenzo-diaza-18-crown-6 exhibited a super-Nernstian response (75±10mV per decade) over the concentration range of 1×10–1 to 7×10–6M of Ag+ ion and a detection limit of 3×10–6M, at a wide range of pH (pH 4–7). The response time of the electrode was fast (less than 10s), and it can be used for three months without any significant deviation in potential. The proposed all-solid-state PVC membrane electrodes revealed high selectivity toward Ag+ ion with respect to alkali, alkaline earth, heavy and transition metal ions. A flow-through cell of all-solid-state PVC membrane Ag+-selective electrode based on N,N-Dibenzyl-dibenzo-diaza-18-crown-6 has also been prepared and applied for flow-injection analysis of Ag+ ion in solution. 相似文献
2.
3.
Avcıbaşı Uğur Türkyarar Taner Karadağ Ayşegül Bakan Buket Yavaşoğlu Nefise Ülkü Karabay Kuşat Kevser Akgöl Sinan Gülcemal Derya Tekin Volkan Müftüler Fazilet Zümrüt Biber Topal Gökcen Parlak Yasemin Gümüşer Fikriye Gül 《Journal of Radioanalytical and Nuclear Chemistry》2021,329(2):511-525
Journal of Radioanalytical and Nuclear Chemistry - The aim of this study is the synthesis of a novel 99mTc-labeld graft polymer and the biological evaluation of its in vitro and in vivo properties.... 相似文献
4.
Suniya Shahzad Leyla Karadurmus Burcu Dogan‐Topal Tugba Taskin‐Tok Afzal Shah Sibel A. Ozkan 《Electroanalysis》2020,32(5):912-922
An electrochemical dsDNA nanobiosensor was fabricated using amino‐functionalized multi walled carbon nanotubes modified glassy carbon electrode (NH2fMWCNTs/GCE) for the sensitive detection of DNA bases and electrochemical monitoring of drug‐DNA interaction. The influence of functional groups on MWCNT was studied by MWCNT functionalized with NH2 (NH2fMWCNTs) and COOH (COOHfMWCNT) groups based on the signal of DNA bases. The modified electrodes were characterized by scanning electron microscopy. One layer of calf thymus double stranded deoxyribonucleic acid (ct‐dsDNA) was immobilized onto the NH2fMWCNTs/GCE (dsDNA/NH2fMWCNTs/GCE). The dsDNA/NH2fMWCNTs/GCE were used to investigate the interaction between the dsDNA and the anticancer drug gemcitabine by differential pulse voltammetry in acetate buffer of pH 4.70. For the confirmation of interaction, the lowering in intensity of the current signals of guanine and adenine was considered as an indicator. Electrochemical impedance spectroscopy studies were performed for the comparison of the modified surfaces. In order to define and visualize the interaction mechanism between gemcitabine and dsDNA/NH2fMWCNTs/GCE at the molecular level, in silico methods including docking and molecular dynamics simulations were employed. 相似文献
5.
Yusuf Kurtulmus T. Tanyalçın Giray Bozkaya Ogˇuzhan Gündüz Ömür Çerçi Fatma Z. Kutay Biltan Ersöz 《Accreditation and quality assurance》2001,6(9-10):424-426
The aim of this study was to compare two immunoassay measurement methods, the ACS:180 Plus (Chiron Diagnostics) kit and the Immulite sPSA (DPC) kit. Method comparison analysis was performed according to EP9-A; approved guideline of NCCLS 51. Serum samples having a wide range of total prostate-specific antigen (PSA) concentrations were evaluated in split-sample analysis. F-test, t-test analysis and regression statistics were performed. In Deming regression analysis the coefficients were as follows; the slope=0.967; y-intercept=-0.148, r=0.989. An acceptable bias was seen since the systematical error was calculated to have a value less than the total allowable error calculated from biological variations. Non-parametric evaluation of the area under ROC curves for ACS:180 Plus and Immulite sPSA were 0.997 and 0.987, respectively. Diagnostic accuracy was at the level of p= 0.000 and no statistical difference was found between the two assay methods. 相似文献
6.
7.
Didem Giray Dilgin Bensu Ertek Yusuf Dilgin 《Journal of the Iranian Chemical Society》2018,15(6):1355-1363
In this work, firstly methylene blue (MB) was electropolymerized onto pencil graphite electrode (PGE) surface for the electrocatalytic oxidation of NADH. Cyclic voltammograms show that oxidation potential of NADH at Poly-MB/PGE shifted to negative direction about 300 mV compared with bare PGE. These results indicate that Poly-MB/PGE exhibits a good electrocatalytic activity toward NADH oxidation. Then, a glucose biosensor study was performed based on the determination of enzymatically generated NADH by glucose dehydrogenase (GDH) which immobilized onto Poly-MB/PGE using glutaraldehyde cross-linking procedure. The biosensing of glucose in flow injection analysis (FIA) system was performed at GDH/Poly-MB/PGE for the first time. The electrocatalytic oxidation currents of enzymatically produced NADH obtained from FI amperometric current–time curves recorded at + 200 mV and in phosphate buffer solution at pH 7.0 containing 1.0 M KCl were linearly related to the concentration of glucose. Linear calibration plots are obtained in the concentration range from 0.01 to 1.0 mM. The limit of detection (LOD) was found to be 4.0 µM. A fast, sensitive, low-cost and disposable glucose biosensor was constructed in FIA system using GDH/Poly-MB/PGE; therefore, it might provide a new perspective for the fabrication of biosensor of other compounds such as glutamate, lactate and alcohol. 相似文献
8.
The anodic behavior and determination of pefloxacin on boron-doped diamond and glassy carbon electrodes were investigated using cyclic, linear sweep, differential pulse and square wave voltammetric techniques. In cyclic voltammetry, pefloxacin shows one main irreversible oxidation peak and additional one irreversible ill-defined wave depending on pH values for both electrodes. The results indicate that the process of pefloxacin is irreversible and diffusion controlled on boron-doped diamond electrode and irreversible but adsorption controlled on glassy carbon electrode. The peak current is found to be linear over the range of concentration 2 × 10−6 to 2 × 10−4 M in 0.5 M H2SO4 at about +1.20 V (versus Ag/AgCl) for differential pulse and square wave voltammetric technique using boron-doped diamond electrode. The repeatability, reproducibility, precision and accuracy of the methods in all media were investigated. Selectivity, precision and accuracy of the developed methods were also checked by recovery studies. The procedures were successfully applied to the determination of the drug in pharmaceutical dosage forms and humans serum samples with good recovery results. No electroactive interferences from the excipients and endogenous substances were found in the pharmaceutical dosage forms and biological samples, respectively. 相似文献
9.
Teslime Erşan Didem Giray Dilgin Elif Kumrulu Umur Kumrulu Yusuf Dilgin 《Electroanalysis》2023,35(4):e202200295
This work describes the sensitive voltammetric determination of favipiravir (FAV) based on its reduction for the first time with a low-cost and disposable pencil graphite electrode (PGE). In addition, the determination of FAV was also performed based on its oxidation. Differential pulse (DP) voltammograms recorded in 0.5 M H2SO4 for the reduction of FAV show that peak currents increase linearly in the range of 1.0 to 600.0 μM with a limit of detection of 0.35 μM. The acceptable recovery values (98.9–106.0 %) obtained from a pharmaceutical tablet, real human urine, and artificial blood serum samples spiked with FAV confirm the high accuracy of the proposed method. 相似文献
10.
Measured (n = 36, 51 ·g/day) and estimated (n = 274, 44 ·g/day) dietary daily intake of selenium in Turkey is low compared to the RDA value of 55 ·g Se/day. When the existence
of high prevalence of iodine deficiency in most part of the country is considered, adequate level of dietary Se becomes more
important. We have found recently that high iodine-deficient goitrous children had lower Se levels and antioxidant enzyme
(AOE) activities, and higher levels of DNA base lesions than non-goitrous controls.
This revised version was published online in August 2006 with corrections to the Cover Date. 相似文献