首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   47篇
  免费   5篇
化学   52篇
  2020年   2篇
  2019年   7篇
  2017年   1篇
  2016年   2篇
  2015年   5篇
  2014年   2篇
  2013年   1篇
  2012年   4篇
  2011年   2篇
  2009年   1篇
  2008年   1篇
  2007年   8篇
  2006年   2篇
  2005年   3篇
  2002年   2篇
  2000年   4篇
  1999年   1篇
  1997年   1篇
  1994年   1篇
  1993年   2篇
排序方式: 共有52条查询结果,搜索用时 15 毫秒
1.
The first example of a self‐propelled tubular motor that releases an enzyme for the efficient biocatalytic degradation of chemical pollutants is demonstrated. How the motors are self‐propelled by the Marangoni effect, involving simultaneous release of SDS surfactant and the enzyme remediation agent (laccase) in the polluted sample, is illustrated. The movement induces fluid convection and leads to the rapid dispersion of laccase into the contaminated solution and to a dramatically accelerated biocatalytic decontamination process. The greatly improved degradation efficiency, compared to quiescent solutions containing excess levels of the free enzyme, is illustrated for the efficient biocatalytic degradation of phenolic and azo‐type pollutants. The high efficiency of the motor‐based decontamination approach makes it extremely attractive for a wide‐range of remediation processes in the environmental, defense and public health fields.  相似文献   
2.
CdS quantum dots/C60 tubular micromotors with chemical/multi‐light‐controlled propulsion and “on‐the‐fly” acceleration capabilities are described. In situ growth of CdS quantum dots on the outer fullerene layer imparts this layer with light‐responsive properties in connection to inner Pt, Pd or MnO2 layers. This is the first time that visible light is used to drive bubble‐propelled tubular micromotors. The micromotors exhibit a broad absorption range from 320 to 670 nm and can be wirelessly controlled by modulating light intensity and peroxide concentration. The built‐in accelerating optical system allows for the control of the velocity over the entire UV/Vis light spectra by modulating the catalyst surface chemistry. The light‐responsive properties have been also exploited to accelerate the chemical dealloying and propulsion of micromotors containing a Cu/Pd layer. Such dual operated hybrid micromotors hold considerable promise for designing smart micromachines for on‐demand operations, motion‐based sensing, and enhanced cargo transportation.  相似文献   
3.
A flexible skin‐mounted microfluidic potentiometric device for simultaneous electrochemical monitoring of sodium and potassium in sweat is presented. The wearable device allows efficient natural sweat pumping to the potentiometric detection chamber, containing solid‐contact ion‐selective Na+ and K+ electrodes, during exercise activity. The fabricated microchip electrolyte‐sensing device displays good analytical performance and addresses sweat mixing and carry‐over issues of early epidermal potentiometric sensors. Such soft skin‐worn microchip platform integrates potentiometric measurement, microfluidic technologies with flexible electronics for real‐time wireless data transmission to mobile devices. The new fully integrated microfluidic electrolyte‐detection device paves the way for practical fitness and health monitoring applications.  相似文献   
4.
5.
Single-walled carbon nanotubes (SWCNTs) should constitute an important natural step towards the improvement of the analytical performance of microfluidic electrochemical sensing. SWCNTs inherently offer lower detection potentials, higher surfaces and better stability than the existing carbon electrodes. However, pristine SWCNTs contain some carbonaceous and metallic impurities that influence their electrochemical performance. Thus, an appropriate processing method is important for obtaining high purity SWCNTs for analytical applications. In this work, a set of 0.1 mg mL(-1) SWCNT dispersions with different degrees of purity and different dispersants (SDBS; pluronic F68 and DMF) was carefully characterized by near infrared (NIR) spectroscopy giving a Purity Index (NIR-PI) ranging from 0.039 to 0.310. The highest purity was obtained when air oxidized SWCNTs were dispersed in SDBS, followed by centrifugation. The SWCNT dispersions were utilized to modify microfluidic chip electrodes for the electrochemical sensing of dopamine and catechol. In comparison with non-SWCNT-based electrodes, the sample with the highest NIR-PI (0.310) exhibited the best analytical performance in terms of improved sensitivity (3-folds higher), very good signal-to-noise ratio, high resistance-to-fouling in terms of relative standard deviation (RSD 7%; n = 15), and enhanced resolution (2-folds higher). In addition, very well-defined concentration dependence was also obtained with excellent correlation coefficients (r ≥ 0.990). Likewise, a good analytical sensitivity, suitable detection limits (LODs) and a very good precision with independence of the concentration assayed (RSDs ≤ 5%) was achieved. These valuable features indicate the suitability of this material for quantitative analysis. NIR-PI and further TEM and XRD characterization demonstrated that the analytical response was driven and controlled by the high NIR-PI of the SWCNTs used. The significance of this work is the demonstration for the first time of the sensitivity-purity relationship in SWCNT microfluidic chips. A novel and valuable analytical tool for electrochemical sensing has been developed: SWCNTs with high purity and a rich surface chemistry with functional groups, both essential for analytical purposes. Also, this work helps to better understand the analytical potency of SWCNTs coupled to microfluidic chips and it opens new gates for using these unique dispersions in real-world applications.  相似文献   
6.
7.
8.
Polyphenolic compounds in apples and pears were analysed by HPLC on C18-modified silica. Gradient elution with phosphoric acid–methanol mixtures and phosphoric acid–acetonitrile mixtures gave complete separation of all polyphenolics of interest. The use of methanol as modifier was preferred because it provides a more rapid separation (20 min). Diode-array detection was used for the provisional identification of polyphenolic compounds not available as standards.  相似文献   
9.
This review highlights the role of electrochemical approaches in the sensing of antioxidants and their antioxidant capacity with especial attention to the analytical possibilities of electrochemistry in the direct evaluation of antioxidant capacity exhibited by food and biological samples due to the termed dietary, natural or biological antioxidants (mainly polyphenols, and vitamins C and E). The analytical potency of the electrochemistry is comprehensively stated and the selected results found in the literature are summarized and discussed critically. The main electrochemical approaches used have been cyclic voltammetry (CV) and flow injection analysis with amperometric detection (FIA‐ED). In addition, miniaturization is going to break new frontiers in the evaluation of antioxidant activity.  相似文献   
10.
A novel analytical route to determine water-soluble vitamins (B group and C) using single channel microchip-electrochemistry platforms is presented. The electrochemical detection protocol was carefully optimized, and it was shown that it was crucial to use 1 M nitric acid in the detector compartment to detect folic acid. A phosphate buffer (pH 6, 10 mM) and a separation voltage of 2 kV gave the complete separation of vitamins in less than 130 s, with good reproducibility (RSDs less than 10%) and accuracy (error less than 9%). In addition, a methodological innovation integrating calibration and analysis of water-soluble vitamins on the chip is also proposed. The strategy consisted in sequentially using both reservoirs (named calibration and analysis reservoirs) as well as a calibration factor (defined as signal/concentration of analyte). The analytical route required 350 s in the overall protocol (employing 130 s in calibration plus 130 s in analysis), an improvement over the times used in both conventional and microchip protocols.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号