首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   7篇
  免费   0篇
化学   7篇
  2013年   1篇
  2012年   1篇
  2011年   1篇
  2009年   1篇
  2008年   2篇
  2007年   1篇
排序方式: 共有7条查询结果,搜索用时 31 毫秒
1
1.
A sensitive and selective high-performance liquid chromatography-positive ion electrospray tandem mass spectrometry method was developed and validated for the quantification of amisulpride in 100 microL of human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective (M + H)(+) ions, m/z 370-242 for amisulpride and m/z 341-112 for the internal standard. The assay exhibited a linear dynamic range with a lower range of 0.1-100 ng/mL and a higher range of 1-500 ng/mL of amisulpride in human plasma. The lower limit of quantification was 0.1 ng/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for both linearity ranges. A run time of 2.0 min for each sample made it possible to analyze more than 275 human plasma samples per day. The validated method has been successfully used to analyze plasma samples for application in pharmacokinetic studies.  相似文献   
2.
A simple, reliable HPLC method with UV detection (295 nm) in rat plasma was developed and validated for quantification of tenatoprazole, a novel proton pump inhibitor, which is in clinical trials. Following a single-step liquid-liquid extraction, the analyte and internal standard were separated using an isocratic mobile phase on a reverse phase C(18) column. The lower limit of quantitation was 20 ng/mL, with a relative standard deviation of less than 10%. A linear dynamic range of 20-6000 ng/mL was established. This HPLC method was validated with between-batch and within-batch precision of 2.9-6.3 and 1.4-5.8%, respectively. The between-batch and within-batch accuracy was 95.1-104.1 and 92.4-101.0%, respectively. This validated method is simple and repeatable enough to be used in pharmacokinetic studies.  相似文献   
3.
A sensitive high-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of quetiapine in rat plasma. Following liquid-liquid extraction, the analyte was separated using a gradient mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H]+ ions, m/z 384 to m/z 221 for quetiapine and m/z 327 to m/z 270 for the internal standard. The assay exhibited a linear dynamic range of 0.25-500 ng/mL for quetiapine in rat plasma. The lower limit of quantification was 0.25 ng/mL with a relative standard deviation of less than 7%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated method was successfully used to analyze rat plasma samples for application in pre-clinical pharmacokinetic studies. This method in rodent plasma could be adapted for quetiapine assay in human plasma.  相似文献   
4.
A high‐performance liquid chromatography/positive ion electrospray tandem mass spectrometry method for the simultaneous quantification of lamivudine, stavudine and nevirapine was developed and validated in dried blood spot (DBS) cards. The analytes were separated using an isocratic mobile phase on a reverse phase column and analyzed by MS/MS in the MRM mode using the respective [M + H]+ ions, m/z 230–112 for lamivudine, m/z 225–127 for stavudine, m/z 267–226 for nevirapine, m/z 383–337 for zidovudine (IS). The lower limit of quantification was 1 ng/mL for both lamivudine and stavudine and 10 ng/mL for nevirapine. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The method was successfully applied to quantify them in a rat pharmacokinetic study in whole blood, plasma and DBS cards after a single oral co‐administration at the dose of 10, 2 and 13 mg/kg for lamivudine, stavudine and nevirapine, respectively, to male Wistar rats. Following oral administration the pharmacokinetic results in all the matrices are in close agreement. Thus accomplishment of this method would facilitate the ease of collection of clinical samples on DBS cards for lamivudine, stavudine and nevirapine during human clinical trials and therapeutic drug monitoring. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   
5.
A simple and sensitive LC‐MS/MS method was developed and validated for the quantitation of pitolisant, an H3 receptor antagonist/inverse agonist. Acetonitrile protein precipitation technique was used to prepare rat blood and brain tissue homogenate samples by using aripiprazole as internal standard (IS). Chromatographic separation was performed by using Xbridge column (2.1 × 50 mm, 3.5 µm) with a gradient elution program. The mobile phase consists of ammonium formate (10 mm ) with 0.2% formic acid and acetonitrile. Multiple reaction monitoring mode was used in positive polarity with a transition of m/z 296.3 → 98.2 for the pitolisant and m/z 448.2 → 285.3 for the IS. The calibration curves were linear in the range of 0.1–100 ng/mL in both the blood and brain homogenate samples. This method was applied to quantify samples obtained from the pharmacokinetic and brain penetration studies in male wistar rats. Mean maximum concentration, area under the curve from zero to infinity and half‐life of the pitolisant were found to be 3.4 ± 1.7 ng/mL, 5 ± 4 ng h/mL and 1.9 ± 0.3 h, respectively, after a 3 mg/kg oral dose. The mean calculated concentrations in the brain were found to be 38, 60 and 52 ng/g at 0.5, 1 and 2 h, respectively. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   
6.
A high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry method for the simultaneous quantification of efavirenz, emtricitabine and tenofovir was developed and validated with 100 microL human plasma. Following solid-phase extraction, the analytes were separated using a gradient mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H]+ ions, m/z 316 to 168 for efavirenz, m/z 248-130 for emtricitabine and m/z 288-176 for tenofovir, m/z 482-258 for rosuvastatin (IS), m/z 260-116 for propranolol (IS). The method exhibited a 100-fold linear dynamic range for all the three analytes in human plasma (20-2000, 2-200 and 20-2000 ng/mL for efavirenz, emtricitabine and tenofovir respectively). The lower limit of quantification was 2 ng/mL for emtricitabine and 20 ng/mL for both efavirenz and tenofovir with a relative standard deviation of less than 11%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The total chromatographic run time of 4 min for each sample made it possible to analyze more than 250 human plasma samples per day. The method is precise and sensitive enough for its intended purpose. The method is also successfully applied to quantify efavirenz, emtricitabine and tenofovir concentrations in a rodent pharmacokinetic study.  相似文献   
7.
A sensitive high‐performance liquid chromatography–positive ion electrospray tandem mass spectrometry (LC‐MS/MS) method was developed and validated for the quantification of methyllycaconitine (MLA) in rat plasma and brain tissue. Following acetonitrile protein precipitation, the analyte was separated using a gradient mobile phase on a reversed‐phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H]+ ions, m/z 683–216 for MLA and m/z 260–116 for the internal standard. The assay exhibited a linear dynamic range of 0.5–250 ng/mL for MLA in rat plasma and brain tissue. The lower limit of quantification was 0.5 ng/mL. Acceptable precision (<12%) and accuracy (100 ± 6%) were obtained for concentrations over the standard curve range. The method was successfully applied to quantify MLA concentrations in a rodent pharmacokinetic and brain penetration study. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号