首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
化学   2篇
物理学   2篇
  2011年   1篇
  2010年   1篇
  2009年   1篇
  2003年   1篇
排序方式: 共有4条查询结果,搜索用时 15 毫秒
1
1.
A sensor for ethanol is described that is based on the fluorescent probe 5,10,15,20-tetraphenyl porphyrin (TPP). Response is based on the quenching of the fluorescence of TPP by ethanol as a result of electrostatic attraction. The sensor linearly responds to ethanol in the concentration range from 1 to 75 vol.% and was applied to the determination of ethanol in various kinds of wines and whisky.  相似文献   
2.
The purpose of this study was to demonstrate the initial results of the dynamic contrast-enhanced MRA in under four seconds in the assessment of anomalous pulmonary circulation. We performed dynamic contrast enhanced MRA on ten patients with a temporal resolution of 2-3 sec for each phase. Five patients had pulmonary vascular anomaly and five patients had reconstructed pulmonary circulation. On nine patients catheter angiography was performed for the correlation. Dynamic contrast-enhanced MRA successfully demonstrated congenital pulmonary vascular anomalies and the pathway of anomalous pulmonary circulation in our series. With the improved temporal and spatial resolution, the dynamic contrast-enhanced MRA can be used in children and infants for the assessment of congenital vascular disease.  相似文献   
3.
Mixtures of boron and azomethine-H in solution result in slow complexation. Addition of sodium dodecyl sulfate (SDS), polyethylene glycol dodecyl ether (Brij-35), 4-(1,1,3,3-tetramethylbutyl)phenyl-polyethylene glycol (TritonX-100), and cetyltrimethyl ammonium bromide (CTAB) result in considerable decrease in complexation time and enhancement in signal of peak in solution and also sol-gel. The fluorescence of the complex is monitored at an emission wavelength of 486 nm with excitation at 416 nm. The presence of 1x10(-3) mol L(-1) SDS decreased the complexation time up to 10 min in solution and 20 min in sol-gel for above 0.25 microg B mL(-1) and 30 min in solution and 35 min in sol-gel for below 0.25 microg B mL(-1). However, the photostability did not change by adding micelle in both media. The proposed method shows a linear response toward boron in the concentration range of 0.05-10 microg mL(-1) and is selective for boron over a large number of electrolytes and cations. The detection limit was 7 microg L(-1). This method has been used for the detection of boron in environmental water samples and fruit juices with satisfactory results.  相似文献   
4.
A finite volume numerical technique is proposed to solve the compressible ideal MHD equations for steady and unsteady problems based on a quasi-Newton implicit time integration strategy. The solenoidal constraint is handled by a hyperbolic divergence cleaning approach allowing its satisfaction up to machine accuracy. The conservation of the magnetic flux is computed in a consistent way using the numerical flux of the finite volume discretization. For the unsteady problem, the time accuracy is obtained by a Newton subiteration at each physical timestep thereby converging the solenoidal constraint to steady state. We perform extensive numerical experiments to validate and demonstrate the capabilities of the proposed numerical technique.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号