首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   63篇
  免费   21篇
  国内免费   40篇
化学   85篇
力学   2篇
物理学   37篇
  2024年   1篇
  2023年   5篇
  2021年   4篇
  2020年   1篇
  2019年   3篇
  2018年   6篇
  2017年   3篇
  2016年   4篇
  2015年   3篇
  2014年   12篇
  2013年   7篇
  2012年   16篇
  2011年   8篇
  2010年   6篇
  2009年   5篇
  2008年   8篇
  2007年   6篇
  2005年   1篇
  2004年   1篇
  2003年   2篇
  2002年   4篇
  2001年   7篇
  2000年   3篇
  1999年   4篇
  1998年   2篇
  1996年   1篇
  1991年   1篇
排序方式: 共有124条查询结果,搜索用时 93 毫秒
1.
The composites with nano-particles of Ni-Fe alloys dispersed on the nano-layers of expanded graphite (EG) were prepared by the impregnation of EG with ethanol solutions of nickel and iron acetates, followed by drying and reduction in H2. The square nano-particles of Ni-Fe alloys with particle sizes of mainly 20~40 nm were found to be well spread on the layers of EG. The alloy nano-particles exhibited high shielding effectiveness (SE) for electromagnetic radiations at low frequencies due to their high magnetic conductivity. Since EG is electronically conductive and displayed high SE at high frequencies, the composites exhibited good SE at wide range of frequencies. The electric and magnetic conductivities of the composites could be monitored through regulating the loadings of alloy nano-particles on EG, and it was found that the composites with 20%~40% of the alloys exhibited good SE. Specifically, the composite 27%Ni-3%Fe-EG showed the excellent SE from 66 to 110 dB at the frequencies from 300 kHz to 1.5 GHz.  相似文献   
2.
在高效液相色谱(HPLC)中,使用多柱串联能够极大地增加柱效和改善分离效果,提高温度能够明显降低色谱柱反压、加快分析速度.将色谱柱串联与提高柱温相结合构建了多柱串联高温HPLC系统,该系统常温下分析标准样品时(以芴计),绝对柱效达7.6×104塔板数;柱温升高到120℃,色谱柱反压从35.3MPa降低到15.4MPa,分析时间从78.39min缩短为19.26min.采用构建的系统分析中药六味地黄丸,常温下出峰94个,升高温度至100℃出峰80个,分离效果较常规的单柱系统有明显提高;升高温度,使主要组分的出峰时间缩短,可获得更为详尽的组成信息.  相似文献   
3.
聚变-裂变混合能源堆包括聚变中子源和次临界能源堆,主要目标是生产电能。回顾了国内外混合堆的发展历史,给出混合能源堆设计的边界条件和约束条件,说明次临界能源堆以铀锆合金为燃料、水为冷却剂的设计思想。利用输运燃耗耦合程序 MCORGS 计算了混合能源的燃耗,给出了中子有效增殖因数、能量放大倍数和氚增殖比等物理量随时间的变化。通过分析能谱和重要核素随燃耗时间的变化,说明混合能源堆与核燃料增殖、核废料嬗变混合堆的不同特点。论述了混合堆的热工设计并进行了安全分析。对于燃耗数值模拟程序,通过多家对算,保证其计算结果的可信性。针对次临界能源堆的特点,利用贫铀球壳建立了贫铀聚乙烯装置和贫铀LiH装置,并且专门设计加工了天然铀装置,开展铀裂变率、造钚率、产氚率等中子学积分实验,验证了数值模拟的可靠性。  相似文献   
4.
利用电磁模拟软件,计算得到了H面渐变与E面渐变的楔形衰减器匹配效果,指出在相同渐变长度下,E面渐变匹配效果优于H面渐变。H面渐变衰减器反射主要来源于电场集中处,而E面渐变衰减器主要来源于渐变前部尖端处。在此基础上设计出了一种变形的匹配衰减器,即在E面渐变衰减器渐变开始处向前延伸一块薄片。计算结果与测试结果表明:与H面渐变和E面渐变的楔形衰减器相比,所设计衰减器在近截止频率处的匹配效果得到了明显的改善。  相似文献   
5.
唐涛 《高分子科学》2014,32(1):51-63
A variety of linear and 3-arm star polyethylene (PE) model polymers covering a wide range of molecular weight are synthesized by the living polymerization of butadiene and the subsequent hydrogenation. Several rheological parameters of these model linear and 3-arm star PE samples are analyzed for detecting the long chain branching (LCB) structure. It is found that the analyses based on zero shear viscosity, vGP plot and flow activation energy are very sensitive to the 3-arm star PEs. The information on the presence of LCB can be obtained with these methods even for low molecular weight samples, which can not be determined by GPC-MALLS. However the information about the LCB structure can not be obtained by the rheological methods alone.  相似文献   
6.
马丽  唐涛 《高分子科学》2014,32(6):731-742
Three-arm and four-arm star-like polybutadienes(PBds) were synthesized via the combination of living anionic polymerization and the click coupling method. Kinetic study showed that the click reaction between the azido group terminated PBd-t-N3 and the alkyne-containing multifunctional linking reagent was fast and highly efficient. All coupling reactions were fully accomplished within 40 min at 50 °C in toluene in the presence of the reducing agent Cu(0), proven by 1H-NMR, FTIR and GPC measurements. For the coupling reactions between the PBd-t-N3 polymer and dialkyne-containing compound, the final conversion of the coupled PBd-PBd polymer was ca. 97.0%. When a PBd-t-N3 polymer was reacted with trialkyne-containing or tetraalkyne-containing compound, the conversion of three-arm or four-arm PBd was around 95.5% or 87.0%, respectively. Several factors influencing the coupling efficiency were studied, including the molecular weight of the initial PBd-t-N3, arm numbers and the molar ratio of the azido group to the alkynyl group. The results indicated that the conversion of the target products would be promoted when the molecular weight of the PBd-t-N3 was low and the molar ratio of the azido to alkynyl groups was close to 1.  相似文献   
7.
通过升高色谱柱温度,结合线性梯度洗脱的分离模式调整色谱分离的选择性,提出了一种测定脑蛋白水解物注射液中氨基酸含量的2,4-二硝基氟苯(DNFB)柱前衍生高效液相色谱方法。本法采用Kromasil C18(250×4.6 mm i.d.,5μm)色谱柱,柱温44℃,在30 min内以3个线性梯度能完全分离17种氨基酸,定量线性范围为0.2~1.0mg/L;加标回收率为89%~108%。该法具有适用性好、稳定性高等特点,也可以应用于其它种类样品中氨基酸的测定。  相似文献   
8.
采用油酸表面改性的粒径均一的Fe3O4磁性纳米粒子(OA-Fe3O4)与具有微相分离结构的聚苯乙烯-b-聚2-乙烯基吡啶(PS-b-P2VP)嵌段共聚物通过溶液共混,得到具有超顺磁性的PS-b-P2VP/Fe3O4纳米复合材料.结果表明,在OA-Fe3O4质量分数为1%,3%,5%和10%时,纳米粒子分散在PS相区;但OA-Fe3O4含量为8%时,纳米粒子在嵌段聚合物基体中的分散状态发生突变,形成大尺寸聚集体并分散在整个基体中,此时复合材料的流变行为发生相应变化.  相似文献   
9.
以十八烷基三氯硅烷和3-巯丙基三甲氧基硅烷为改性剂,采用一锅法对硅胶表面加以修饰,进一步将巯基氧化制备成C18-磺酸基双改性液相色谱固定相.在优化的反应条件下得到了十八烷基和磺酸基摩尔比为3∶7的固定相,分别采用扫描电镜、元素分析、红外光谱对固定相的形貌和特征加以表征.针对制备的固定相,在不同的分离模式下,系统考察其色谱分离性能.在反相色谱模式下,成功分离了5种烷基苯化合物;在亲水模式下,分离了3种核苷;进一步应用于牛血清白蛋白酶解产物的分离,得到了较好的结果.实验结果表明,制备的混合模式固定相同时具有多种分离机理,在分离复杂样品、调整选择性方面具有潜在的优势.  相似文献   
10.
通过正硅酸乙酯分别在聚甲基丙烯酸甲酯乳液和四氢呋喃溶液中的溶胶-凝胶反应制备出不同的聚甲基丙烯酸甲酯/二氧化硅复合材料。利用扫描电镜、透镜电镜、差热分析和热失重对试样进行了分析。结果表明,利用聚合物乳液可以获得纳米分散的聚甲基丙烯酸甲酯/二氧化硅复合材料,并且在某种程度上其分散尺度小于利用聚合物溶液获得的复合材料。同时,利用聚合物乳液来制备聚甲基丙烯酸甲酯/二氧化硅杂化材料更有利于凝胶过程中二氧化硅网络的形成。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号