首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
无线电   4篇
  1994年   1篇
  1989年   1篇
  1988年   1篇
  1986年   1篇
排序方式: 共有4条查询结果,搜索用时 0 毫秒
1
1.
We discuss circuit parameters that limit the precision of basic dynamic current-memory cells. In addition to analyzing current-copying errors caused by the finite output conductances of the current sources and by the clock-feedthrough (CFT) of the feedback switches, we analyze the noise performance of the basic memory cell. To reduce CFT and noise, we propose a novel circuit based on Miller capacitance-enhancement. Measurement results of memory cells integrated in a 1-μm CMOS process confirm the theoretical findings; with our CFT and noise reduction technique based on Miller enhanced capacitance and dummy switches, we achieve a dynamic range of 11 b at clock frequencies greater than 100 kHz  相似文献   
2.
The application of floating-gate elements as adjustable components in analog CMOS circuits such as amplifiers is proposed. A simple trimming circuit based on this principle and delivering a differential current is described. Experimental results of a differential difference amplifier (DDA) containing two such circuits are given. After trimming, an offset voltage of 10 μV and a nonlinearity of 0.1% are achieved. Other analog circuits based on floating-gate elements like adjustable voltage sources and transconductances have been realized. Because they can be electrically reprogrammed, a wide range of applications, for example in neural nets, are possible  相似文献   
3.
CMOS current Schmitt trigger with fully adjustable hysteresis   总被引:2,自引:0,他引:2  
A CMOS current Schmitt trigger whose hysteresis is independent of process parameters, transistor dimensions and power supplies is described. The hysteresis is determined by two currents and is adjustable over the range of the input current. The circuit function can be extended to a two-input current comparator with adjustable hysteresis.<>  相似文献   
4.
The construction and specific function of a new ultrasonic flowmeter are described. The mean velocity of the respiratory air flow is calculated by measuring the transit times of short ultrasonic pulse-trains simultaneously transmitted upstream and downstream at a 650 Hz rate. The flowmeter system consists of a control unit and a separate flowhead. The former includes the power supplies, a controlling microprocessor, most of the signal processing circuitry, and three analog outputs for flow, volume, and temperature, respectively. The flowhead contains the respiratory tube with a constant circular cross section (length 90 mm, diameter 20 mm, dead space 35 cm3), a fast temperature sensor, two electronic circuits for processing of flow and temperature data, and a sound transmission channel with two capacitive ultrasonic wide-band transducers. This respiratory air flowmeter is extremely fast (response time 1-2 ms) and accurate, with low noise (below 9ml/s), with a wide flow range (bidirectional from 0 to 9 l/s) and with a linear frequency response up to 70 Hz.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏