排序方式: 共有53条查询结果,搜索用时 15 毫秒
1.
2.
3.
An experimental study of the thermal decomposition of a β‐hydroxy alkene, 3‐methyl‐3‐buten‐1‐ol, in m‐xylene solution, has been carried out at five different temperatures in the range of 513.15–563.15 K. The temperature dependence of the rate constants for the decomposition of this compound in the corresponding Arrhenius equation is given by ln k (s?1) = (25.65 ± 1.52) ? (17,944 ± 814) (kJ·mol?1)·T?1. A computational study has been carried out at the M05–2X/6–31+G(d,p) level of theory to calculate the rate constants and the activation parameters by the classical transition state theory. There is a good agreement between the experimental and calculated rate constants and activation Gibbs energies. The bonding characteristics of reactant, transition state, and products have been investigated by the natural bond orbital analysis, which provides the natural atomic charges and the Wiberg bond indices. Based on the results obtained, the mechanism proposed is a one‐step process proceeding through a six‐membered cyclic transition state, being a concerted and slightly asynchronous process. The results have been compared with those obtained previously by us (Struct Chem 2013, 24, 1811–1816) for the thermal decomposition of 3‐buten‐1‐ol, in m‐xylene solution. We can conclude that in the compound studied in this work, 3‐methyl‐3‐buten‐1‐ol, the effect of substitution at position 3 by a weakly activating CH3 group is the stabilization of the transition state formed in the reaction and therefore a small increase in the rate of thermal decomposition. 相似文献
4.
Abstract Due to the wide use of polymers in medicine, researchers are required to solve a very important problem–to understand the interaction between materials of nonphysiological origin and the surrounding biological liquids, and tissues, particularly blood. 相似文献
5.
Gerig A Chen Q Zagzebski J Varghese T 《The Journal of the Acoustical Society of America》2004,116(3):1832-1841
Ultrasonic scatterer size estimates generally have large variances due to the inherent noise of spectral estimates used to calculate size. Compounding partially correlated size estimates associated with the same tissue, but produced with data acquired from different angles of incidence, is an effective way to reduce the variance without making dramatic sacrifices in spatial resolution. This work derives theoretical approximations for the correlation between these size estimates, and the coherence between their associated spectral estimates, as functions of ultrasonic system parameters. A Gaussian spatial autocorrelation function is assumed to adequately model scatterer shape. Both approximations compare favorably with simulation results, which consider validation near the focus. Utilization of the correlation/coherence expressions for statistical analysis and optimization is discussed. Approximations, such as the invariance of phase and amplitude terms with angle, are made to obtain closed-form solutions to the derived spectral coherence near the focus and permit analytical optimization analysis. Results indicate that recommended parameter adjustments for performance improvement generally depend upon whether, for the system under consideration, the primary source of change in total coherence with rotation is phase term variation due to the change in the relative position of scattering sites, or field amplitude term variation due to beam movement. 相似文献
6.
Gerig A Zagzebski J Varghese T 《The Journal of the Acoustical Society of America》2003,113(6):3430-3437
A theoretical expression for the variance of scatterer size estimates is derived for a modified least squares size estimator used in conjunction with a reference phantom method for backscatter coefficient measurement. A Gaussian spatial autocorrelation function is assumed. Simulations and phantom experiments were performed to verify the results for backscatter and size variances. The dependence of size estimate errors upon free experimental parameters is explored. Implications of the findings for the optimization of scatterer size estimation are discussed. The utility of scatterer size parametric imaging is examined through the signal to noise ratio comparison with standard ultrasonic B-mode imaging. 相似文献
7.
T J Hall E L Madsen J A Zagzebski E J Boote 《The Journal of the Acoustical Society of America》1989,85(6):2410-2416
The accuracy of a method of data reduction for determining acoustic backscatter coefficients was tested using focused transducers and narrow-band pulses. Two phantoms with well-defined scattering properties were the bases of the tests, one having low attenuation and one with tissue-mimicking attenuation. The experimentally determined backscatter coefficients were found to be independent of transducer-to-scattering-volume distance and to agree very well with theoretical values, typically within 10%. 相似文献
8.
9.
10.
Z.M. Babar Wan Mohd Azizi Solachuddin JA Ichwan Qamar Uddin Ahmed Abul Kalam Azad Imranul Mawa 《Natural product research》2019,33(15):2266-2270
The current study provides a way of extraction for both active NSO and WSE from Nigella sativa seeds using 98% methanol. About 1?kg of ground seeds was macerated by 1:2.5 w/v (g/mL) for 72?hours. After rotary evaporation and 7 days of continuous drying and chilling at 50 and 4?°C, NSO and WSE were obtained at the same instant. Solubility tests of 24 solvents and 11 thin layer chromatographic analyses while 2, 2-diphenyl-1-picrylhydrazyl free radical scavenging assay of NSO (73.66) , WSE (33.32) and NSO?+?WSE (78.22) against ascorbic acid (IC50?=?4.28?mg/mL) was performed. WSE was found to be highly soluble in water and 5% NaOH exhibiting the same Rf value of 0.95 for EtOH:DMSO (9:1) against the honey. WSE has revealed more than twofold higher anti-oxidant activity than others. Formulation of WSE with Tualang honey may provide better targeted hydrophilic drug delivery systems. 相似文献