Nonlinear Dynamics - The perovskite solar cell (PSC) is one of the most promising photovoltaic candidates along with the highly increasing demand for green electricity. One of the main concerns... 相似文献
Journal of Solid State Electrochemistry - An ultrasensitive “signal-off–on” electrochemiluminescence (ECL) biosensor is constructed based on f1-TiO2/g-C3N4/PDA for thrombin... 相似文献
Russian Journal of General Chemistry - Aminophosphabetaines, i.e., isobutyl {[alkyl(dimethyl)ammonio]methyl}phosphonates with higher alkyl substituents at the nitrogen atom, were obtained by a... 相似文献
Amlexanox, an anti-inflammatory and anti-allergic agent, has been widely used clinically for the treatment of canker sores, asthma, and allergic rhinitis. Recently, amlexanox has received considerable attention in curing nonalcoholic fatty liver diseases and hepatitis virus infection. Herein, we first established a sensitive high-performance liquid chromatography-tandem mass spectrum (LC–MS/MS) method for the determination of amlexanox in rat plasma. Propranolol was used as the internal standard (IS). Using a simple protein precipitation method, the amlexanox and IS were separated with Capcell Pak C18 column (2.0 × 50 mm, 5 μm) and eluted with water and acetonitrile each containing 0.1% formic acid using gradient elution condition at a flow rate of 0.4 mL·min−1. Amlexanox and IS were detected by a triple quadrupole mass in multiple reactive monitoring (MRM) under the transitions of m/z 299.2 → 281.2 and m/z 259.9 → 116.1 with positive electrospray ionization, respectively. The calibration curves of amlexanox were established with the range of 50 to 2000 ng·mL−1 (r2 > 0.99). The validation method consisted of selectivity, accuracy, precision, carryover effect, matrix effect, recovery, dilution effect, and stability. The fully validated method was successfully applied to the pharmacokinetic study of amlexanox in Wistar rats. 相似文献
Refractory wounds have always been an important issue to healthcare systems, whose healing process is always delayed by multiple factors, including bacterial infections, chronic inflammation, and excessive exudates, etc. Employing multifunctional wound dressings is recognized as an effective strategy to deal with refractory wounds, which has yielded promising outcomes in recent years. Among these advanced wound dressings, fibrous dressings have gained growing attention due to their unique merits. Such wound dressings have demonstrated great potential in delivering theranostic agents, such as antibacterial agents, anti-inflammatory drugs, growth factors, and diagnostic probes, etc., for the purposes of accelerating wound healing. This paper reviews the development of multifunctional fibrous dressings and their applications in treating refractory wounds. The construction approaches of novel fibrous dressing with capabilities of antibacterial, anti-inflammation, exudate management and diagnosis were also introduced. Furthermore, the existing problems and challenges are also discussed briefly. 相似文献
The aim of this study is to develop and validate a sensitive and specific stability-indicating reversed-phase high-performance liquid chromatographic (RP-HPLC) method for the quantitative determination of Sugammadex sodium together with its process and possible degradation impurities. The pKa value is 2.82. The chromatographic conditions have been optimized by the Hypersil Gold 250 mm X 4.6 mm, 3 µ RP-18 columns with gradient elution using a mobile phase composed of 0.1% phosphoric acid, acetonitrile, and methanol. The eluents were monitored at 205 nm with a flow rate of 1.0 mL/min with an injection volume of 20 µL. The optimized method produced symmetrical and sharp peaks with good separation between the process and degradation impurities. The forced degradation study was carried out under acid, base, oxidation, and thermal conditions to demonstrate the stability-indicating capability of the method. The method was validated as per the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH) Q2 (R1) and showed excellent specificity, precision, linearity, accuracy, and robustness. The developed HPLC method was precise with a value of 0.25%. The relative standard deviation of accuracy represented by the recovery studies ranged between 89.5% and 104.6%. Linearity analyses indicated a correlation coefficient value of greater than 0.996 for Sugammadex and its known impurities. The LOD and LOQ values for Sugammadex ranged from 0.017% to 0.050%, and for its related impurities, they ranged from 0.015% to 0.055%. The stability of the analytical solution was evaluated and was stable for 75 h when stored at 5 °C. No chromatographic interference was observed during the degradation studies and also in the blank chromatogram.
High Energy Chemistry - Modification of Polyvinylidene fluoride (PVDF) by radiation grafting is a research hotspot in recent years. In this study, the monomer 2-Hydroxyethyl methacrylate (HEMA) was... 相似文献
At present, the reactivity of cyclic alkanes is estimated by comparison with acyclic hydrocarbons. Due to the difference in the structure of cycloalkanes and acycloalkanes, the thermodynamic data obtained by analogy are not applicable. In this study, a molecular beam sampling vacuum ultraviolet photoionization time-of-flight mass spectrometer (MB-VUV-PI-TOFMS) was applied to study the low-temperature oxidation of cyclopentane (CPT) at a total pressure range from 1–3 atm and low-temperature range between 500 and 800 K. Low-temperature reaction products including cyclic olefins, cyclic ethers, and highly oxygenated intermediates (e. g., ketohydroperoxide KHP, keto-dihydroperoxide KDHP, olefinic hydroperoxides OHP and ketone structure products) were observed. Further investigation of the oxidation of CPT – electronic structure calculations – were carried out at the UCCSD(T)-F12a/aug-cc-pVDZ//B3LYP/6-31+ G(d,p) level to explore the reactivity of O2 molecules adding sequentially to cyclopentyl radicals. Experimental and theoretical observations showed that the dominant product channel in the reaction of CPT radicals with O2 is HO2 elimination yielding cyclopentene. The pathways of second and third O2 addition – the dissociation of hydroperoxide – were further confirmed. The results of this study will develop the low-temperature oxidation mechanism of CPT, which can be used for future research on accurately simulating the combustion process of CPT. 相似文献