首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   28篇
  免费   0篇
化学   9篇
数学   4篇
物理学   15篇
  2022年   1篇
  2021年   2篇
  2020年   1篇
  2016年   1篇
  2013年   1篇
  2012年   1篇
  2008年   1篇
  2000年   1篇
  1999年   2篇
  1998年   2篇
  1997年   1篇
  1996年   1篇
  1995年   2篇
  1992年   1篇
  1990年   1篇
  1988年   2篇
  1987年   3篇
  1986年   4篇
排序方式: 共有28条查询结果,搜索用时 15 毫秒
1.
2.
Water diffusion measurements were performed on rabbit Achilles tendons during static tensile loading and tendons in an unloaded state. The apparent diffusion coefficient (ADC) was measured along two directions: parallel and perpendicular to the long axis of the tendon. Tendons were studied after being prepared in two ways: (a) after being stored frozen in phosphate-buffered saline (PBS) and (b) freshly isolated. Statistically significant directional anisotropy was observed in the ADC in all tendons. The ADC was significantly greater in the direction parallel to the long axis of the tendon than in the perpendicular direction. The anisotropy is attributed to the greater restrictions seen by the water molecules in the perpendicular direction and is consistent with the known geometry of the tendon. Storage in PBS caused tendons to swell. This increased the ADC measured along both directions and reduced the anisotropy. The existence of anisotropy in the ADC was not related to the orientation of the specimen in the magnet. The ADC increased along both directions following the application of a 5-N tensile load; the increase was greatest along the perpendicular axis of the tendon. In order to determine whether load-related changes in the ADC reflected changes in interfibrilar spacing, we used electron microscopy to measure load-related changes in fibril spacing. Load-related changes in fiber spacing could not account for the observed changes in the ADC. The increase in ADC caused by loading was attributed to the extrusion of tendon water into a bulk phase along the outside surface of the tendon. In PBS-stored samples, enough fluid was extruded that it could be visualized. The transient response of the ADC to a 5-N tensile load was also studied. The absolute ADC in both directions increased with loading and recovered to baseline upon unloading. The transient changes in ADC, for both loading and unloading, had a mean time constant of approximately 15 min. The magnitude of the load-induced transient ADC changes was comparable to that seen in the static-loading experiments.  相似文献   
3.
Using the approach of Rulla (1996 SIAM J. Numer. Anal. 33, 68-87)for analysing the time discretization error and assuming moreregularity on the initial data, we improve on the error boundderived by Barrett and Blowey (1996 IMA J. Numer. Anal. 16,257-287) for a fully practical piecewise linear finite elementapproximation with a backward Euler time discretization of amodel for phase separation of a multi-component alloy.  相似文献   
4.
5.
6.
7.
8.
9.
This work is concerned with the melting behaviour and accuracy of differential scanning calorimeter (DSC) analyses of poly(3-hydroxybutyrate) (PHB), a semi-crystalline thermoplastic polymer completely biodegradable and biocompatible, and obtained from renewable resources. Melting parameters of PHB were determined for the first fusion event applying standard experimental procedures for thermal analysis, using heating rates ranging between 1 °C/min and 20 °C/min. The analyses of DSC energy flow scans showed a complex melting peak that may be resolved into three elementary peaks having different intensities at different melting temperatures. Peak temperatures depend on heating rate, while the total crystallinity detected was independent of the rate. A study of 24 DSC runs showed good temperature reproducibility (±0.5 °C), but poor reproducibility of mass crystallinity (±10%).  相似文献   
10.
We consider a model for phase separation of a multi-componentalloy with a concentration-dependent mobility matrix and logarithmicfree energy. In particular we prove that there exists a uniquesolution for sufficiently smooth initial data. Further, we provean error bound for a fully practical piecewise linear finiteelement approximation in one and two space dimensions. Finallynumerical experiments with three components in one space dimensionare presented.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号