排序方式: 共有34条查询结果,搜索用时 765 毫秒
1.
2.
3.
AA Yan LI Kai CAO ZhongHua & HU WenRui Key Laboratory of Microgravity 《中国科学:物理学 力学 天文学(英文版)》2011,(2)
The dependency of the critical Marangoni number on the geometrical aspect ratio of the floating half zone is essential to predict the onset of oscillatory thermocapillary convection.The experimental studies in the microgravity conditions on floating half zones of several centimeters in diameter have predicted that the critical Marangoni number increases with the increasing aspect ratio,and the terrestrial experimental studies have predicted the contradictory conclusion for floating half zones of several mil... 相似文献
4.
Non-Gravitational Effects with Density-Matching in Evaluating the Influence of Sedimentation on Colloidal Coagulation
下载免费PDF全文
![点击此处可从《中国物理快报》网站下载免费的PDF全文](/ch/ext_images/free.gif)
The method of density matching between the solid and liquid phases is often adopted to effectively eliminate the effect of sedimentation of suspensions in studies on dynamic behaviour of a colloidal system. However, the associated changes in the solvent composition may bring side effects to the properties investigated and therefore might lead to a faulty conclusion if the relevant correction is not made. To illustrate the importance of this side effect, we present an example of the sedimentation influence on the coagulation rate of suspensions of 2μm (diameter) polystyrene. The liquid mixtures, in the proper proportions of water (H2O), deuterium oxide (D2O) and methanol (MeOH) as the liquid phase, density-matched and unmatched experiments are performed. Besides the influence of viscosity, the presence of methanol in solvent media, used to enhance the sedimentation effect, causes significant changes (reduction) in rapid coagulation rates compared to that in pure water. Without the relevant corrections for those non-gravitational factors it seems that gravitational sedimentation would retard the coagulation. The magnitude of the contribution from the non-gravitational factor is quantitatively determined, making the relevant correction possible. After necessary the influence of the sedimentation on coagulation rates at corrections for all factors, our experiments show that the initial stage of the coagulation is not observable. 相似文献
5.
6.
7.
We discuss the notion of spin squeezing considering two mutually exclusive classes of spin-s states, namely, oriented and non-oriented states. Our analysis shows that the oriented states are not squeezed while non-oriented
states exhibit squeezing. We also present a new scheme for construction of spin-s states using 2s spinors oriented along different axes. Taking the case of s=1, we show that the ‘non-oriented’ nature and hence squeezing arise from the intrinsic quantum correlations that exist among
the spinors in the coupled state. 相似文献
8.
It is widely recognised that the measurement of the arterial input function (AIF) is a key issue and a major source of errors in the pharmacokinetic modelling of dynamic, contrast-enhanced magnetic resonance imaging (DCE-MRI) data, and the modality of the AIF determination is still a matter of debate. In this study we addressed the problem of the intrinsic variability of the AIF within the imaged volume of a DCE-MRI scan by systematically investigating the change in the concentration of contrast agent over time and the fit parameters of the derived vascular input function (VIF) obtained from the superior sagittal sinus (SSS) of a patient population that was scanned longitudinally during treatment for high grade glioma. From a total of 82 scanning sessions, we compared the results obtained with three different DCE-MRI protocols and between two different fitting functions. We applied a correction algorithm to the measured concentration-time curves to minimize the effect of the low temporal resolution on the VIF, and investigated the effect of this algorithm on the reproducibility. Finally, where possible, we compared the signal obtained in the SSS to the signal obtained in the middle cerebral artery. We found a good intrapatient reproducibility of both the measured gadolinium concentrations and VIF parameters, and that the variation of the parameters due to slice location within a patient was significantly lower than the intra patient variation. Intrapatient, interscan differences were significantly less marked than inter-patient differences showing a good intraclass correlation coefficient. We did encounter a MRI protocol dependence of the VIF fitting parameters. The correction algorithm significantly improved the reproducibility of the fitting parameters. These results support the idea that the use of a patient specific measured AIF, not necessarily averaged over a large volume, offers a significant benefit with respect to an external AIF or a measured cohort average AIF. 相似文献
9.
10.