排序方式: 共有8条查询结果,搜索用时 13 毫秒
1
1.
Bailey JE Chandler GA Slutz SA Golovkin I Lake PW MacFarlane JJ Mancini RC Burris-Mog TJ Cooper G Leeper RJ Mehlhorn TA Moore TC Nash TJ Nielsen DS Ruiz CL Schroen DG Varnum WA 《Physical review letters》2004,92(8):085002
Hot dense capsule implosions driven by Z-pinch x rays have been measured using a approximately 220 eV dynamic Hohlraum to implode 1.7-2.1 mm diameter gas-filled CH capsules. The capsules absorbed up to approximately 20 kJ of x rays. Argon tracer atom spectra were used to measure the T(e) approximately 1 keV electron temperature and the n(e) approximately 1-4 x 10(23) cm(-3) electron density. Spectra from multiple directions provide core symmetry estimates. Computer simulations agree well with the peak emission values of T(e), n(e), and symmetry, indicating reasonable understanding of the Hohlraum and implosion physics. 相似文献
2.
Varnum WS Delamater ND Evans SC Gobby PL Moore JE Wallace JM Watt RG Colvin JD Turner R Glebov V Soures J Stoeckl C 《Physical review letters》2000,84(22):5153-5155
Inertial confinement fusion implosions using capsules with two concentric shells separated by a low density region (double shells) are reported which closely follow one dimensional (1D) radiatively driven hydrodynamics simulations. Capsule designs which mitigate Au M-band radiation asymmetries appear to correspond more closely to 1D simulations than targets lacking mitigation of hohlraum drive M-band nonuniformities. One capsule design achieves over 50% of the unperturbed 1D calculated yield at a convergence ratio of 25.5, comparable to that of a double-shell design for an ignition capsule at the National Ignition Facility. 相似文献
3.
Background
Tone languages such as Thai and Mandarin Chinese use differences in fundamental frequency (F0, pitch) to distinguish lexical meaning. Previous behavioral studies have shown that native speakers of a non-tone language have difficulty discriminating among tone contrasts and are sensitive to different F0 dimensions than speakers of a tone language. The aim of the present ERP study was to investigate the effect of language background and training on the non-attentive processing of lexical tones. EEG was recorded from 12 adult native speakers of Mandarin Chinese, 12 native speakers of American English, and 11 Thai speakers while they were watching a movie and were presented with multiple tokens of low-falling, mid-level and high-rising Thai lexical tones. High-rising or low-falling tokens were presented as deviants among mid-level standard tokens, and vice versa. EEG data and data from a behavioral discrimination task were collected before and after a two-day perceptual categorization training task.Results
Behavioral discrimination improved after training in both the Chinese and the English groups. Low-falling tone deviants versus standards elicited a mismatch negativity (MMN) in all language groups. Before, but not after training, the English speakers showed a larger MMN compared to the Chinese, even though English speakers performed worst in the behavioral tasks. The MMN was followed by a late negativity, which became smaller with improved discrimination. The High-rising deviants versus standards elicited a late negativity, which was left-lateralized only in the English and Chinese groups.Conclusion
Results showed that native speakers of English, Chinese and Thai recruited largely similar mechanisms when non-attentively processing Thai lexical tones. However, native Thai speakers differed from the Chinese and English speakers with respect to the processing of late F0 contour differences (high-rising versus mid-level tones). In addition, native speakers of a non-tone language (English) were initially more sensitive to F0 onset differences (low-falling versus mid-level contrast), which was suppressed as a result of training. This result converges with results from previous behavioral studies and supports the view that attentive as well as non-attentive processing of F0 contrasts is affected by language background, but is malleable even in adult learners. 相似文献4.
We report a dye-encapsulated silica nanoparticle as a label, with the advantages of high fluorescence intensity, photostability, and biocompatibility, in conjunction with microarray technology for sensitive immunoassay of a biomarker, interleukin-6 (IL-6), on a microarray format. The tris(2,2'-bipyridyl)ruthenium(ii) chloride hexahydrate (Rubpy) dye was incorporated into silica nanoparticles using a simple one-step microemulsion synthesis. In this synthesis process, Igepal CA520 was used as the surfactant, therefore, no requirement of cosolvent during the synthesis and the particle size was reduced comparing to the commonly used Triton surfactant system. The nanoparticles are uniform in size with a diameter of 50 nm. The microarray fluorescent immunoassay approach based on dye-doped silica nanoparticle labels has high sensitivity for practical applications with a limit of detection for IL-6 down to 0.1 ng mL(-1). The calibration curve is linear over the range from 0.1 ng mL(-1) to 10 ng mL(-1). Furthermore, results illustrated that the assay is highly specific for IL-6 in the presence of range of cytokines or proteins. The RuDS dye-labeled nanoparticles in connection with protein microarrays show the promise for clinical diagnosis of biomarkers. 相似文献
5.
RD Harris WS Baker Van Stipdonk MJ RM Crooks EA Schweikert 《Rapid communications in mass spectrometry : RCM》1999,13(14):1374-1380
A suite of keV polyatomic or 'cluster' projectiles was used to bombard unoxidized and oxidized self-assembled monolayer surfaces. Negative secondary ion yields, collected at the limit of single ion impacts, were measured and compared for both molecular and fragment ions. In contrast to targets that are orders of magnitude thicker than the penetration range of the primary ions, secondary ion yields from polyatomic projectile impacts on self-assembled monolayers show little to no enhancement when compared with monatomic projectiles at the same velocity. This unusual trend is most likely due to the structural arrangement and bonding characteristics of the monolayer molecules with the Au(111). Copyright 1999 John Wiley & Sons, Ltd. 相似文献
6.
James M Varnum Janina Baraniak Renata Kaczmarek Wojciech J Stec Charles Brenner 《BMC chemical biology》2001,1(1):3-6
Background
The human FHIT gene is inactivated early in the development of many human cancers and loss of Fhit in mouse predisposes to cancer while reintroduction of FHIT suppresses tumor formation via induction of apoptosis. Fhit protein, a diadenosine polyphosphate hydrolase, does not require hydrolase activity to function in tumor suppression and may signal for apoptosis as an enzyme-substrate complex. Thus, high affinity nonhydrolyzable substrate analogs may either promote or antagonize Fhit function, depending on their features, in Fhit + cells. Previously synthesized analogs with phosphorothioadenosyl substitutions and "supercharged" branches do not bind better than natural substrates and thus have limited potential as cellular probes. 相似文献7.
Varnum SM Warner MG Dockendorff B Anheier NC Lou J Marks JD Smith LA Feldhaus MJ Grate JW Bruckner-Lea CJ 《Analytica chimica acta》2006,570(2):137-143
Two immunoassay platforms were developed for either the sensitive or rapid detection of botulinum neurotoxin A (BoNT/A), using high-affinity recombinant monoclonal antibodies against the receptor binding domain of the heavy chain of BoNT/A. These antibodies also bind the same epitopes of the receptor binding domain present on a nontoxic recombinant heavy chain fragment used for assay development and testing in the current study. An enzyme-linked immunosorbent assay (ELISA) microarray using tyramide amplification for localized labeling was developed for the specific and sensitive detection of BoNT. This assay has the sensitivity to detect BoNT in buffer and blood plasma samples down to 14 fM (1.4 pg mL−1). Three capture antibodies and one antibody combination were compared in the development of this assay. Using a selected pair from the same set of recombinant monoclonal antibodies, a renewable surface microcolumn sensor was developed for the rapid detection of BoNT/A in an automated fluidic system. The ELISA microarray assay, because of its sensitivity, offers a screening test with detection limits comparable to the mouse bioassay, with results available in hours instead of days. The renewable surface assay is less sensitive but much faster, providing results in less than 10 min. 相似文献
8.
1