首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   68篇
  免费   1篇
  国内免费   2篇
化学   38篇
数学   11篇
物理学   22篇
  2021年   1篇
  2019年   1篇
  2018年   1篇
  2016年   2篇
  2015年   2篇
  2014年   2篇
  2013年   3篇
  2012年   1篇
  2011年   4篇
  2010年   5篇
  2009年   4篇
  2008年   8篇
  2007年   4篇
  2006年   5篇
  2005年   2篇
  2004年   8篇
  2003年   4篇
  2002年   2篇
  2000年   1篇
  1999年   1篇
  1998年   1篇
  1997年   2篇
  1995年   2篇
  1994年   1篇
  1992年   1篇
  1991年   1篇
  1987年   1篇
  1981年   1篇
排序方式: 共有71条查询结果,搜索用时 31 毫秒
1.
2.
Thomson scattering of high-power laser and electron beams is a good test of electrodynamics in the high-field region. We demonstrated production of high-intensity X-rays in the head-on collision of a CO2 laser and 60-MeV electron beams at Brookhaven National Laboratory, Accelerator Test Facility. The energy of an X-ray photon was limited at 6.5 keV in the linear (lowest order) Thomson scattering, but the nonlinear (higher order) process produces higher energy X-rays. We measured the angular distribution of the high-energy X-rays and confirmed that it agrees with theoretical predictions.  相似文献   
3.
We report enantioselective synthesis of phyllanthurinolactone (1), a leaf-closing substance of Phyllanthus urinaria L., and its analogs with sugars other than d-glucose. Structure-activity relationship study using them revealed that the structure of the sugar moiety did not affect their bioactivity at all. This result is very important for the development of molecular probes based on the structure of 1.  相似文献   
4.
The diffusion of six azo and five anthraquinone derivatives through nylon 6, poly(ethylene terephthalate) and secondary cellulose acetate films were studied under high hydrostatic pressures of up to 3000 bar and at temperatures 80–130 °C, by analyzing the diffusion profiles yielded in a stacked multiple film, placed in the solution of the diffusant. It was found that the diffusion coefficient,D, of the diffusant decreased with increasing pressure, giving a linear relationship between InD and the pressure, the slope of which gave the activation volume for the diffusion,V . It was revealedV increased linearly with increasing intrinsic molecular volume of the diffusant,V w , the slopes being different between the azo and the anthraquinone derivatives. The ratio ofV toV w (V /V w ) ranged from 0.13 to 0.93, depending in a sensitive manner on the degree of swelling of the polymer matrix which in turn was varied by the solvent. The overall results could be explained in accordance with the formulation,V f, local +V =V w , whereV f, local represents the free volume contribution. It was proposed thatV w is increased by solvation when the solvent is good for the diffusant.  相似文献   
5.
Asymmetric selective (or stereoelective) polymerization of various racemic methacrylates with cyclohexylmagnesium bromide (c-HexMgBr)-(-)sparteine (1/1.2) catalyst was studied in toluene at ?78°C. The methacrylates of α-ethylbenzyl (EBMA), α-isopropylbenzyl (i-PBMA), α-tert-butylbenzyl (t-BBMA), sec-butyl (s-BuMA), 1-methylallyl (1-MAMA), 2,3-epoxypropyl (2,3-EPMA), 2-phenylpropyl (2-PPMA), and menthyl (MentMA) alcohols were used as racemic monomers. In the polymerization of EBMA and i-PBMA (S) enantiomers were consumed preferentially and the optical purity of initially polymerized i-PBMA was as high as 97%. Optically pure (R) monomers were recovered at about 60% conversion for i-PBMA and 80% for EBMA. In t-BBMA, however, the (R) monomer was consumed preferentially over the (S) isomer. In the polymerization of s-BuMA and 1-MAMA (S) monomers were consumed in excess and the optical purity of the polymers formed in the early stage was about 30%. In 2,3-EPMA and 2-PPMA, which have asymmetric centers at the β position from the ester oxygen, (R) antipodes were more reactive. MentMA did not polymerize at ?78°C. Enantiomer selectivity ratios rS and rR were determined in the polymerization of EBMA, i-PBMA, and 1-MAMA. All polymers except poly(t-BBMA) were highly isotactic, but the tacticity of poly(t-BBMA) could not be estimated. Circular dichroism spectra of optically active polymers of α-substituted benzyl esters were measured.  相似文献   
6.
Electron beams with the lowest, normalized transverse emittance recorded so far were produced and confirmed in single-bunch-mode operation of the Accelerator Test Facility at KEK. We established a tuning method of the damping ring which achieves a small vertical dispersion and small x-y orbit coupling. The vertical emittance was less than 1% of the horizontal emittance. At the zero-intensity limit, the vertical normalized emittance was less than 2.8 x 10(-8) rad m at beam energy 1.3 GeV. At high intensity, strong effects of intrabeam scattering were observed, which had been expected in view of the extremely high particle density due to the small transverse emittance.  相似文献   
7.
An experiment on the investigation of optical diffraction radiation (ODR) from a slit target as a possible tool for noninvasive electron beam-size diagnostics has been performed at the KEK accelerator test facility. The experimental setup has been installed at the diagnostics section of the extraction line. We have performed the first incoherent ODR observation from a slit target. The measured angular distributions are in reasonable agreement with the theoretical expectation. The beam-size effect onto the ODR angular pattern has been observed. Moreover, the sensitivity to the beam size as small as 14 microm has been achieved.  相似文献   
8.
We represent the first experimental observation of the point spread function (PSF) of optical transition radiation (OTR) performed at KEK-Accelerator Test Facility extraction line. We have demonstrated that the PSF vertical polarization component has a central minimum with a two lobe distribution. However, the distribution width varied significantly with wavelength. We assume that we observed a severe effect from spherical or chromatic aberrations which are not taken into account in any existing theoretical model. We believe that the result of this work will encourage theoreticians to continue developing the theory as it is important for various transition radiation applications. Nonuniform distribution of the OTR PSF creates an opportunity for developing a submicrometer transverse beam size monitor.  相似文献   
9.
The Laser Undulator Compact X-ray source(LUCX) is a test bench for a compact high brightness X-ray generator,based on inverse Compton Scattering at KEK,which requires high intensity multi-bunch trains with low transverse emittance.A photocathode RF gun with emittance compensation solenoid is used as an electron source.Much endeavor has been made to increase the beam intensity in the multi-bunch trains.The cavity of the RF gun is tuned into an unbalanced field in order to reduce space charge effects,so that the field gradient on the cathode surface is relatively higher when the forward RF power into gun cavity is not high enough.A laser profile shaper is employed to convert the driving laser profile from Gaussian into uniform.In this research we seek to find the optimized operational conditions for the decrease of the transverse emittance.With the uniform driving laser and the unbalanced RF gun,the RMS transverse emittance of a 1 nC bunch has been improved effectively from 5.46 πmm.mrad to 3.66 πmm.mrad.  相似文献   
10.
Dedicated to Professor Noboru Tanaka in his sixtieth birthday  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号