首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   7篇
  免费   0篇
化学   3篇
数学   1篇
物理学   3篇
  2017年   1篇
  2015年   1篇
  2013年   1篇
  2011年   1篇
  2010年   1篇
  2008年   1篇
  2000年   1篇
排序方式: 共有7条查询结果,搜索用时 0 毫秒
1
1.
We use tools of the equilibrium statistical mechanics of disordered systems to study analytically the statistical properties of an ecosystem composed of N species interacting via random mutual interactions, as well as via deterministic self-interactions of order p>/=2. We show that the main effect of increasing the order of the interactions among the species is to make the system less competitive, in the sense that the fraction of extinct species is greatly reduced. In addition, we find that for p>2 there is a threshold value which gives a lower bound to the concentration of the surviving species, preventing then the existence of rare species and, consequently, increasing the robustness of the ecosystem to external perturbations.  相似文献   
2.
The objective of this study was to develop a novel analytical chemistry method, comprised of a coupled high-performance liquid chromatography–gas chromatography/mass spectrometry system (LC–GC/MS) with low detection limits and high selectivity, for the identification and determination of oxygenated polycyclic aromatic hydrocarbons (OPAHs) and polycyclic aromatic hydrocarbons (PAHs) in urban air and diesel particulate matter. The linear range of the four OPAHs, which include 9,10-anthraquinone, 4H-cyclopenta[def]phenanthrene-4-one, benzanthrone, and 7,12-benz[a]anthraquinone, was 0.7 pg–43.3 ng with limits of detection (LODs) and limits of quantification (LOQs) on the order of 0.2–0.8 and 0.7–1.3 pg, respectively. The LODs in this study are generally lower than values reported in the literature, which can be explained by using large-volume injection. The recoveries of the OPAHs spiked onto glass fiber filters using two different pressurized liquid extraction (PLE) methods were in the ranges of 84–107 and 67–110 %, respectively. The analytical protocols were validated using the following National Institute of Standards and Technology standard reference materials: SRM 1649a (Urban Dust), SRM 1650b (Diesel Particulate Matter), and SRM 2975 (Diesel Particulate Matter, Industrial Forklift). The measured mass fractions of the OPAHs in the standard reference materials (SRMs) in this present study are higher than the values from the literature, except for benzanthrone in SRM 1649a (Urban Dust). In addition to the OPAHs, 44 PAHs could be detected and quantified from the same particulate extract used in this protocol. Using data from the literature and applying a two-sided t test at the 5 % level using Bonferroni correction, significant differences were found between the tested PLE methods for individual PAHs. However, the measured mass fractions of the PAHs were comparable, similar to, or higher than those previously reported in the literature.  相似文献   
3.
The efficiency of extraction of polycyclic aromatic hydrocarbons (PAHs) with molecular masses of 252, 276, 278, 300, and 302 Da from standard reference material diesel particulate matter (SRM 2975) has been investigated using accelerated solvent extraction (ASE) with dichloromethane, toluene, methanol, and mixtures of toluene and methanol. Extraction of SRM 2975 using toluene/methanol (9:1, v/v) at maximum instrumental settings (200 °C, 20.7 MPa, and five extraction cycles) with 30-min extraction times resulted in the following elevations of the measured concentration when compared with the certified and reference concentrations reported by the National Institute of Standards and Technology (NIST): benzo[b]fluoranthene, 46%; benzo[k]fluoranthene, 137%; benzo[e]pyrene, 103%; benzo[a]pyrene, 1,570%; perylene, 37%; indeno[1,2,3-cd]pyrene, 41%; benzo[ghi]perylene, 163%; and coronene, 361%. The concentrations of the following PAHs were comparable to the reference values assigned by NIST: indeno[1,2,3-cd]fluoranthene, dibenz[a,h]anthracene, and picene. The measured concentration of dibenzo[a,e]-pyrene was lower than the information value reported by the NIST. The measured concentrations of other highly carcinogenic PAHs (dibenzo[a,l]pyrene, dibenzo[a,i]pyrene, and dibenzo[a,h]pyrene) in SRM 2975 are also reported. Comparison of measurements using the optimized ASE method and using similar conditions to those applied by the NIST for the assignment of PAH concentrations in SRM 2975 indicated that the higher values obtained in the present study were associated with more complete extraction of PAHs from the diesel particulate material. Re-extraction of the particulate samples demonstrated that the deuterated internal standards were more readily recovered than the native PAHs, which may explain the lower values reported by the NIST. The analytical results obtained in the study demonstrated that the efficient extraction of PAHs from SRM 2975 is a critical requirement for the accurate determination of PAHs with high molecular masses in this standard reference material and that the optimization of extraction conditions is essential to avoid underestimation of the PAH concentrations. The requirement is especially relevant to the human carcinogen benzo[a]pyrene, which is commonly used as an indicator of the carcinogenic risk presented by PAH mixtures.  相似文献   
4.
Behavioral and ecological studies would benefit from the ability to automatically identify species from acoustic recordings. The work presented in this article explores the ability of hidden Markov models to distinguish songs from five species of antbirds that share the same territory in a rainforest environment in Mexico. When only clean recordings were used, species recognition was nearly perfect, 99.5%. With noisy recordings, performance was lower but generally exceeding 90%. Besides the quality of the recordings, performance has been found to be heavily influenced by a multitude of factors, such as the size of the training set, the feature extraction method used, and number of states in the Markov model. In general, training with noisier data also improved recognition in test recordings, because of an increased ability to generalize. Considerations for improving performance, including beamforming with sensor arrays and design of preprocessing methods particularly suited for bird songs, are discussed. Combining sensor network technology with effective event detection and species identification algorithms will enable observation of species interactions at a spatial and temporal resolution that is simply impossible with current tools. Analysis of animal behavior through real-time tracking of individuals and recording of large amounts of data with embedded devices in remote locations is thus a realistic goal.  相似文献   
5.

Background

We examined development of auditory temporal integration and inhibition by assessing electrophysiological responses to tone pairs separated by interstimulus intervals (ISIs) of 25, 50, 100, 200, 400, and 800 ms in 28 children aged 7 to 9 years, and 15 adults.

Results

In adults a distinct neural response was elicited to tones presented at ISIs of 25 ms or longer, whereas in children this was only seen in response to tones presented at ISIs above 100 ms. In adults, late N1 amplitude was larger for the second tone of the tone pair when separated by ISIs as short as 100 ms, consistent with the perceptual integration of successive stimuli within the temporal window of integration. In contrast, children showed enhanced negativity only when tone pairs were separated by ISIs of 200 ms. In children, the amplitude of the P1 component was attenuated at ISIs below 200 ms, consistent with a refractory process.

Conclusions

These results indicate that adults integrate sequential auditory information into smaller temporal segments than children. These results suggest that there are marked maturational changes from childhood to adulthood in the perceptual processes underpinning the grouping of incoming auditory sensory information, and that electrophysiological measures provide a sensitive, non-invasive method allowing further examination of these changes.  相似文献   
6.
By analogy with Feller’s general probabilistic scheme used in the construction of many classical convergent sequences of linear operators, in this paper, we consider a Feller-kind scheme based on the possibilistic integral, for the construction of convergent sequences of nonlinear operators. In particular, in the discrete case, all the so-called max-product Bernstein-type operators and their qualitative convergence properties are recovered. Also, discrete nonperiodic nonlinear possibilistic convergent operators of Picard type, Gauss–Weierstrass type and Poisson–Cauchy type are studied and the possibility of introduction of discrete periodic(trigonometric) nonlinear possibilistic operators of de la Vallée–Poussin type, of Fejér type and of Jackson type is mentioned as future directions of research.  相似文献   
7.
A multidimensional, on-line coupled liquid chromatographic/gas chromatographic system was developed for the quantification of polycyclic aromatic hydrocarbons (PAHs). A two-dimensional liquid chromatographic system (2D-liquid chromatography (LC)), with three columns having different selectivities, was connected on-line to a two-dimensional gas chromatographic system (2D-gas chromatography (GC)). Samples were cleaned up by combining normal elution and column back-flush of the LC columns to selectively remove matrix constituents and isolate well-defined, PAH enriched fractions. Using this system, the sequential removal of polar, mono/diaromatic, olefinic and alkane compounds from crude extracts was achieved. The LC/GC coupling was performed using a fused silica transfer line into a programmable temperature vaporizer (PTV) GC injector. Using the PTV in the solvent vent mode, excess solvent was removed and the enriched PAH sample extract was injected into the GC. The 2D-GC setup consisted of two capillary columns with different stationary phase selectivities. Heart-cutting of selected PAH compounds in the first GC column (first dimension) and transfer of these to the second GC column (second dimension) increased the baseline resolutions of closely eluting PAHs. The on-line system was validated using the standard reference materials SRM 1649a (urban dust) and SRM 1975 (diesel particulate extract). The PAH concentrations measured were comparable to the certified values and the fully automated LC/GC system performed the clean-up, separation and detection of PAHs in 16 extracts in less than 24 h. The multidimensional, on-line 2D-LC/2D-GC system eliminated manual handling of the sample extracts and minimised the risk of sample loss and contamination, while increasing accuracy and precision.
Figure
Scheme of the 2D-LC/2D-GC system  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号