首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   7篇
  免费   0篇
数学   1篇
物理学   6篇
  2004年   1篇
  1999年   2篇
  1996年   1篇
  1993年   1篇
  1986年   1篇
  1977年   1篇
排序方式: 共有7条查询结果,搜索用时 46 毫秒
1
1.
2.
The x-ray diffraction intensities of Bragg reflections have been measured at room temperature for thulium selenide, samarium sulphide, samarium selenide and samarium telluride. On the basis of a common amplitude approximation, the Debye-Waller factor, the mean amplitude of vibration and the Debye temperature have been evaluated. The values of the Debye temperatures and mean amplitudes of vibration are 176±16°K, 0·185 ± 0·017 Å (TmSe), 155 ± 7°K, 0·244 ± 0·012 Å (SmS), 153 ± 14°K, 0·221 ± 0·020 Å (SmSe) and 151 ± 20°K, 0·204 ± 0·027 Å (SmTe).  相似文献   
3.
4.
A rigorous investigation of the identification of a heterogeneousflexural rigidity coefficient in the Euler-Bernoulli steady-statebeam theory in the presence of a prescribed load is presented.Mathematically, this study is an extension to higher-order differentialequations of the coefficient identification problem analysedby Marcellini (1982) for the one-dimensional Poisson equation.In addition, various types of boundary conditions are discussed.Conditions for the well-posedness of these inverse problemsare established and, furthermore, numerical results obtainedusing a regularization algorithm are presented.  相似文献   
5.
The sensitivity of all ion trap mass spectrometry (ITMS) methods is dependent on the trapping efficiency of the instrument. For ITMS instruments utilizing external ion sources, such as laser desorption, trapping efficiency is known to depend on the phase and amplitude of the radio frequency (RF) potential applied to the ring electrode at the time of ion introduction. It is remarkable that, in a considerable body of literature, no consensus exists regarding the effects of these parameters on the efficacy of trapping externally generated ions. In this paper, a summary of the literature is presented in order to highlight significant discrepancies. New laser desorption ion trap mass spectrometry (LD-ITMS) data are also presented, from which conclusions are drawn in our effort to clarify some of the confusion. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
6.
7.
Distortion generated by the cochlea can provide a valuable indicator of its functional state. In the present study, the dependence of distortion on the operating point of the cochlear transducer and its relevance to endolymph volume disturbances has been investigated. Calculations have suggested that as the operating point moves away from zero, second harmonic distortion would increase. Cochlear microphonic waveforms were analyzed to derive the cochlear transducer operating point and to quantify harmonic distortions. Changes in operating point and distortion were measured during endolymph manipulations that included 200-Hz tone exposures at 115-dB SPL, injections of artificial endolymph into scala media at 80, 200, or 400 nl/min, and treatment with furosemide given intravenously or locally into the cochlea. Results were compared with other functional changes that included action potential thresholds at 2.8 or 8 kHz, summating potential, endocochlear potential, and the 2 f1-f2 and f2-f1 acoustic emissions. The results demonstrated that volume disturbances caused changes in the operating point that resulted in predictable changes in distortion. Understanding the factors influencing operating point is important in the interpretation of distortion measurements and may lead to tests that can detect abnormal endolymph volume states.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号