首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   10篇
  免费   0篇
化学   2篇
数学   1篇
物理学   7篇
  2020年   1篇
  2012年   2篇
  2007年   1篇
  2006年   1篇
  2003年   1篇
  2002年   1篇
  2000年   1篇
  1999年   1篇
  1977年   1篇
排序方式: 共有10条查询结果,搜索用时 343 毫秒
1
1.
A high performance liquid chromatographic-mass spectrometric (LC/MS) assay was developed and validated for the determination of BMS-204352 in dog K(3)EDTA plasma. A 0.5 mL aliquot of control plasma was spiked with BMS-204352 and internal standard (IS) and buffered with 1 mL of 5 mM ammonium acetate. The mixture was then extracted with 3 mL of toluene. After separation and evaporation of the organic phase to dryness using nitrogen at 40 degrees C, the residue was reconstituted in the mobile phase and 25 microL of the sample were injected onto a Hypersil C(18) column (2 x 50 mm; 3 microm) at a flow rate of 0.5 mL/min. The mobile phase was consisted of two solvent mixtures (A and B). Solvent A was composed of 5 mM ammonium acetate and 0.1% triethylamine in 75:25 v/v water:methanol, pH adjusted to 5.5 with glacial acetic acid, and solvent B was 5 mM ammonium acetate in methanol. A linear gradient system was used to elute the analytes. The mass spectrometer was programmed to admit the de-protonated molecules at m/z 352.7 (IS) and m/z 357.9 (BMS-204352). Standard curves of BMS-204352 were linear (r(2) > or = 0.998) over the concentration range of 0.5-1000 ng/mL. The mean predicted quality control (QC) concentrations deviated less than 5.1% from the corresponding nominal values (ie 4, 80, 400 and 2000 ng/mL); the within- and between-assay precision of the assay were within 5.5% relative standard deviation. Stability of BMS-204352 was confirmed after at least three freeze/thaw cycles and BMS-204532 was stable in dog plasma when stored frozen at or below -20 degrees C for at least 16 weeks in spiked QC samples and for at least 4 1/2 weeks for in vivo study samples. BMS-204352 and IS were stable in the injection solvent at room temperature for at least 24 h. The assay was applied to delineate the pharmacokinetic disposition of BMS-204352 in dogs following a single intravenous dose administration. In conclusion, the assay is accurate, precise, specific, sensitive and reproducible for the pharmacokinetic analysis of BMS-204532 in dog plasma.  相似文献   
2.
Recent experiments suggest that the Ising pyrochlore magnets Ho2Ti2O7 and Dy2Ti2O7 display qualitative properties of the nearest-neighbor "spin ice" model. We discuss the dipolar energy scale present in both these materials and discuss how spin-ice behavior can occur despite the presence of long-range dipolar interactions. We present results of numerical simulations and a mean field analysis of Ising pyrochlore systems. Based on our quantitative theory, we suggest that the spin-ice behavior in these systems is due to long-range dipolar interactions, and that the nearest-neighbor exchange in Dy2Ti2O7 is antiferromagnetic.  相似文献   
3.
BC Paul 《Pramana》1999,53(5):833-841
We obtain exact cosmological solutions of a higher derivative theory described by the Lagrangian L=R+2αR 2 in the presence of interacting scalar field. The interacting scalar field potential required for a known evolution of the FRW universe in the framework of the theory is obtained using a technique different from the usual approach to solve the Einstein field equations. We follow here a technique to determine potential similar to that used by Ellis and Madsen in Einstein gravity. Some new and interesting potentials are noted in the presence of R 2 term in the Einstein action for the known behaviours of the universe. These potentials in general do not obey the slow rollover approximation.  相似文献   
4.
We compare the orbital angular momentum of the ‘quark’ in the scalar diquark model as well as that of the electron in QED (to order α) obtained from the Jaffe–Manohar decomposition to that obtained from the Ji relation. We estimate the importance of the vector potential in the definition of orbital angular momentum.  相似文献   
5.
The notion of continuity for continuous-time information sources which was introduced by Pinsker has found numerous applications in information theory. Continuity in probability is an important concept in the theory of continuous-time stochastic processes. It is shown that these two forms of continuity are equivalent for stationary processes whose state space is a separable metric space.  相似文献   
6.
Rapid field scan on the order of T/s using high frequency sinusoidal or triangular sweep fields superimposed on the main Zeeman field, was used for direct detection of signals without low-frequency field modulation. Simultaneous application of space-encoding rotating field gradients have been employed to perform fast CW EPR imaging using direct detection that could, in principle, approach the speed of pulsed FT EPR imaging. The method takes advantage of the well-known rapid-scan strategy in CW NMR and EPR that allows arbitrarily fast field sweep and the simultaneous application of spinning gradients that allows fast spatial encoding. This leads to fast functional EPR imaging and, depending on the spin concentration, spectrometer sensitivity and detection band width, can provide improved temporal resolution that is important to interrogate dynamics of spin perfusion, pharmacokinetics, spectral spatial imaging, dynamic oxymetry, etc.  相似文献   
7.
Abstract

A series of seven coumarinyl-amino acid ester conjugates have been synthesized and characterized by NMR (1H and 13C) and mass spectra. Further, the compounds were investigated for their therapeutic applications such as anti-inflammatory and antioxidant activities. Among the synthesized compounds most of the analogs showed good efficiency compared with the standard.  相似文献   
8.
The application of correlation spectroscopy employing stochastic excitation and the Hadamard transform to time-domain Fourier transform electron paramagnetic resonance (FT-EPR) spectroscopy in the radiofrequency (RF) band is described. An existing, time-domain FT-EPR spectrometer system with a Larmor frequency (L(f)) of 300 MHz was used to develop this technique by incorporating a pseudo-random pulse sequence generator to output the maximum length binary sequence (MLBS, 10- and 11-bit). Software developed to control the EPR system setup, acquire the signals, and post process the data, is outlined. The software incorporates the Hadamard transform algorithm to perform the required cross-correlation of the acquired signal and the MLBS after stochastic excitation. To accommodate the EPR signals, bandwidth extension was accomplished by sampling at a rate many times faster than the RF pulse repetition rate, and subsequent digital signal processing of the data. The results of these experiments showed that there was a decrease in the total acquisition time, and an improved free induction decay (FID) signal-to-noise (S/N) ratio compared to the conventional coherent averaging approach. These techniques have the potential to reduce the RF pulse power to the levels used in continuous wave (CW) EPR while retaining the advantage of time-domain EPR methods. These methods have the potential to facilitate the progression to in vivo FT-EPR imaging of larger volumes.  相似文献   
9.
The integration of modern data acquisition and digital signal processing (DSP) technologies with Fourier transform electron paramagnetic resonance (FT-EPR) imaging at radiofrequencies (RF) is described. The FT-EPR system operates at a Larmor frequency (L(f)) of 300MHz to facilitate in vivo studies. This relatively low frequency L(f), in conjunction with our approximately 10MHz signal bandwidth, enables the use of direct free induction decay time-locked subsampling (TLSS). This particular technique provides advantages by eliminating the traditional analog intermediate frequency downconversion stage along with the corresponding noise sources. TLSS also results in manageable sample rates that facilitate the design of DSP-based data acquisition and image processing platforms. More specifically, we utilize a high-speed field programmable gate array (FPGA) and a DSP processor to perform advanced real-time signal and image processing. The migration to a DSP-based configuration offers the benefits of improved EPR system performance, as well as increased adaptability to various EPR system configurations (i.e., software configurable systems instead of hardware reconfigurations). The required modifications to the FT-EPR system design are described, with focus on the addition of DSP technologies including the application-specific hardware, software, and firmware developed for the FPGA and DSP processor. The first results of using real-time DSP technologies in conjunction with direct detection bandpass sampling to implement EPR imaging at RF frequencies are presented.  相似文献   
10.
We report an infrared optical study of the pnictide high-temperature superconductor BaFe(1.84)Co(0.16)As(2) and its parent compound BaFe(2)As(2). We demonstrate that electronic correlations are moderately strong and do not change across the spin-density wave transition or with doping. By examining the energy scale and direction of spectral weight transfer, we argue that Hund's coupling J is the primary mechanism that gives rise to correlations.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号