首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   73篇
  免费   4篇
化学   45篇
晶体学   4篇
物理学   28篇
  2024年   1篇
  2023年   1篇
  2022年   2篇
  2021年   3篇
  2020年   3篇
  2016年   5篇
  2014年   5篇
  2013年   4篇
  2012年   4篇
  2011年   4篇
  2010年   2篇
  2008年   4篇
  2007年   8篇
  2006年   4篇
  2005年   2篇
  2004年   1篇
  2003年   2篇
  2001年   5篇
  1999年   1篇
  1998年   1篇
  1996年   3篇
  1995年   1篇
  1994年   1篇
  1988年   1篇
  1985年   3篇
  1984年   5篇
  1983年   1篇
排序方式: 共有77条查询结果,搜索用时 234 毫秒
1.
Low-dimensional systems are formed by planar metal dithiolene complexes which stack as columnar structures in the solid state. Stronger interactions among units within a chain leads to highly anisotropic magnetic properties. The magnetic effects are a manifestation of exchange interaction,J and can be studied through detailedepr techniques in conjunction with magnetic susceptibility and x-ray crystal structure. A brief review of such studies carried out mostly in our laboratory is presented along with the relevant background materials.  相似文献   
2.
The total synthesis of 7,10‐epimer of the proposed structure of amphidinolide N was accomplished. The requisite chiral C17–C29 subunit was assembled stereoselectively via Keck allylation, Shi epoxidation, diastereoselective 1,3‐reduction, and a later oxidative synthesis of the THF framework. The C1–C13 and C17–C29 subunits were successfully coupled using a Enders RAMP “linchpin” as the C14–C16 three carbon unit, thereby controlling the chirality at C14 and C16. The labile allyl epoxy moiety was successfully constructed by Grieco–Nishizawa olefination at a final stage of the synthesis.  相似文献   
3.
In continuous wave (CW) electron paramagnetic resonance imaging (EPRI), high quality of reconstructed image along with fast and reliable data acquisition is highly desirable for many biological applications. An accurate representation of uniform distribution of projection data is necessary to ensure high reconstruction quality. The current techniques for data acquisition suffer from nonuniformities or local anisotropies in the distribution of projection data and present a poor approximation of a true uniform and isotropic distribution. In this work, we have implemented a technique based on Quasi-Monte Carlo method to acquire projections with more uniform and isotropic distribution of data over a 3D acquisition space. The proposed technique exhibits improvements in the reconstruction quality in terms of both mean-square-error and visual judgment. The effectiveness of the suggested technique is demonstrated using computer simulations and 3D EPRI experiments. The technique is robust and exhibits consistent performance for different object configurations and orientations.  相似文献   
4.
Design of highly efficient phosphorescent emitters based on metal‐ and heavy atom‐free boron compounds has been demonstrated by taking advantage of the singlet fission process. The combination of a suitable molecular scaffold and appropriate electronic nature of the substituents has been utilized to tailor the phosphorescence emission properties in solution, neat solid, and in doped PMMA thin films.  相似文献   
5.
There has been a need for development of microwave resonator designs optimized to provide high sensitivity and high stability for EPR spectroscopy and imaging measurements of in vivo systems. The design and construction of a novel reentrant resonator with transversely oriented electric field (TERR) and rectangular sample opening cross section for EPR spectroscopy and imaging of in vivo biological samples, such as the whole body of mice and rats, is described. This design with its transversely oriented capacitive element enables wide and simple setting of the center frequency by trimming the dimensions of the capacitive plate over the range 100-900 MHz with unloaded Q values of approximately 1100 at 750 MHz, while the mechanical adjustment mechanism allows smooth continuous frequency tuning in the range +/-50 MHz. This orientation of the capacitive element limits the electric field based loss of resonator Q observed with large lossy samples, and it facilitates the use of capacitive coupling. Both microwave performance data and EPR measurements of aqueous samples demonstrate high sensitivity and stability of the design, which make it well suited for in vivo applications.  相似文献   
6.
Benzyl and naphthylmethyl vinyl ethers are inert in LPDE medium, whereas hetcroaromntic methyl vinyl ethers, viz., 2-furyl and 2-thicnylmelhyl vinyl ethers undergo formal [1,3] rearrangement in LPDE medium.  相似文献   
7.
8.
9.
An investigation of the kinetics of oxidation of epimeric piperidin-4-ols, oxan-4-ols, and cyclohexanol by N-chloro-r -2, c -6-diphenyl-t -3-methylpiperidin-4-one (NCP) in aqueous acetic acid in the presence of perchloric acid shows that the reaction is first-order each in substrate and oxidant. Both H3O+ and Cl? which catalyze the reaction, exhibit a fractional order kinetics. While increase in ionic strength increases the rate slightly, an inverse dependence is observed between rate and solvent polarity. Addition of r -2-c -6-diphenyl-t -3-methylpiperidin-4-one, one of the reaction products, did not influence the rate. Also, no kinetic isotope effect has been observed. A plausible mechanism consistent with these observations is proposed and the relative reactivities of the substrates are explained on conformational grounds. © 1994 John Wiley & Sons, Inc.  相似文献   
10.
Size controlled cubic Fe3O4 nanoparticles in the size range 90–10 nm were synthesized by varying the ferric ion concentration using the oxidation method. A bimodal size distribution was found without ferric ion concentration and the monodispersity increased with higher concentration. The saturation magnetization decreased from 90 to 62 emu/g when the particle size is reduced to 10 nm. The Fe3O4 nanoparticles with average particle sizes 10 and 90 nm were surface modified with prussian blue. The attachment of prussian blue with Fe3O4 was found to depend on the concentration of HCl and the particle size. The saturation magnetization of prussian blue modified Fe3O4 varied from 10 to 80 emu/g depending on the particle size. The increased tendency for the attachment of prussian blue with smaller particle size was explained based on the surface charge. The prussian blue modified magnetite nanoparticles could be used as a radiotoxin remover in detoxification applications.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号