首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   9篇
  免费   0篇
化学   5篇
力学   1篇
物理学   3篇
  2007年   2篇
  2006年   1篇
  2002年   1篇
  2001年   2篇
  1999年   2篇
  1910年   1篇
排序方式: 共有9条查询结果,搜索用时 15 毫秒
1
1.
The kinetics of oxidation of amino acids (Arg, His, Lys, Phe, Thr and Tyr), a dipeptide (Gly-His), and BSA (bovine serum albumin) by two persistent water soluble free radicals of the hydrazyl type has been studied.The rate decreases in the order Arg>Lys>Tyr>Thr>HisBSAPheGly-His with bothfree radicals. Addition to the reaction mixture of - and -cyclodextrin decreases the oxidation rate, probably due to amino acidencapsulation in the cyclodextrin cavity. -Cyclodextrin protects more efficiently against oxidation than -cyclodextrin.  相似文献   
2.
3.
4.
EM Forgan  D Charalambous  PG Kealey 《Pramana》2002,58(5-6):899-901
We have used a variety of microscopic techniques to reveal the structure and motion of flux line arrangements, when the flux lines in low T c type II superconductors are caused to move by a transport current. Using small-angle neutron scattering by the flux line lattice (FLL), we are able to demonstrate directly the alignment by motion of the nearest-neighbor FLL direction. This tends to be parallel to the direction of flux line motion, as had been suspected from two-dimensional simulations. We also see the destruction of the ordered FLL by plastic flow and the bending of flux lines. Another technique that our collaboration has employed is the direct measurement of flux line motion, using the ultra-high-resolution spectroscopy of the neutron spin-echo technique to observe the energy change of neutrons diffracted by moving flux lines. The muon spin rotation (μSR) technique gives the distribution of values of magnetic field within the FLL. We have recently succeeded in performing μSR measurements while the FLL is moving. Such measurements give complementary information about the local speed and orientation of the FLL motion. We conclude by discussing the possible application of this technique to thin film superconductors.  相似文献   
5.
The properties of the Franssen effect (FE) were measured in budgerigars and zebra finches. To elicit the FE, listeners are presented with a signal which has been split into a transient component, carrying an abrupt onset and ramped offset and separated in space from the sustained component which has a slowly rising onset and longer duration. When these two signals are played under certain conditions, the perception is that of a long-duration steady state tone being played at the location of the transient. The birds were trained using operant conditioning methods on a categorization task to peck a left key when presented with a stimulus from a left speaker and to peck a right key when presented with a stimulus from a right speaker. Once training was completed, FE stimuli were presented during a small proportion of trials. The FE was measured at speaker separations of 60 degrees and 180 degrees in both echoic and echoic-reduced conditions. Both species of birds exhibited the FE, although to varying degrees, across conditions. These results show that nonmammals also experience the FE illusion in confusing listening situations in a manner similar to mammals, suggestive of similar auditory processing mechanisms.  相似文献   
6.
We present HPLC/UV/MS evidence to support the identification of benzo[ghi]naphtho[8,1,2-bcd]perylene as a product of supercritical toluene pyrolysis. Mass spectral data confirm that compound I-eluting in between co-eluting benzo[a]coronene/phenanthro[5,4,3,2-efghi]perylene and benzo[pqr]naphtho[8,1,2-bcd]perylene, all three of which have been unequivocally identified as C(28)H(14) products of toluene pyrolysis-is also a C(28)H(14) product component. The UV spectrum of compound I is presented, and indicates that it is a benzenoid polycyclic aromatic hydrocarbon (PAH). Five of the eight benzenoid C(28)H(14) PAH isomers have published UV spectra, and characteristics of the remaining three are deduced from annelation theory. Only one of these compounds, benzo[ghi]naphtho[8,1,2-bcd]perylene, is predicted to have a UV spectrum with characteristics that we find in the spectrum of compound I. In addition, benzo[ghi]naphtho[8,1,2-bcd]perylene is the only benzenoid C(28)H(14) isomer whose length-to-breadth ratio is consistent with the HPLC retention time of compound I. The reaction mechanism through which benzo[ghi]naphtho[8,1,2-bcd]perylene is formed in this environment is shown, and is consistent with reaction pathways of other large PAH found in this product mixture.  相似文献   
7.
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
8.
Tribenzo[cd,ghi,lm]perylene has been identified as a product of the supercritical pyrolysis of both toluene and Fischer-Tropsch synthetic jet fuel. This identification is based on HPLC/UV/MS data, which show that compound I, eluting immediately after five other C28H14 isomers, is also a C28H14 PAH. The UV spectrum of compound I has features of a benzenoid PAH, of which there are only eight C28H14 isomers. Four of these isomers--benzo[a]coronene, phenanthro[5,4,3,2-efghi]perylene, benzo[cd]naphtho[3,2,1,8-pqra]perylene, and benzo[pqr]naphtho[8,1,2-bcd]perylene--have already been identified as supercritical pyrolysis products by matching their UV spectra with those of respective reference standards. A fifth C28H14 PAH--benzo[ghi]naphtho[8,1,2-bcd]perylene, which does not have a reference standard--has also been recently identified through MS and UV data, use of annellation theory to predict UV spectral characteristics, and length-to-breadth ratio/retention time data. Of the remaining three isomers, bisanthene (IUPAC name phenanthro[1,10,9,8-opqra]perylene) has been determined not to be present in our product mixture, as its UV spectrum does not match that of any of our product PAH. Using annellation theory, we predict the UV spectral characteristics of the two remaining C28H14 benzenoid isomers, for which there are no reference standards (tribenzo[cd,ghi,lm]perylene and naphthaceno[3,4,5,6,7-defghij]naphthacene). Results from this analysis show that the predicted UV spectral features of tribenzo[cd,ghi,lm]perylene match those of compound I--and that those of naphthaceno[3,4,5,6,7-defghij]naphthacene are inconsistent with those of compound I. The length-to-breadth ratio of tribenzo[cd,ghi,lm]perylene also agrees with compound I's HPLC elution behavior. This is the first time that tribenzo[cd,ghi,lm]perylene (IUPAC name phenanthro[2,1,10,9,8,7-pqrstuv]pentaphene) has been identified as a product of fuel pyrolysis or combustion.  相似文献   
9.
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号