首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   3篇
  免费   0篇
化学   2篇
物理学   1篇
  2004年   1篇
  1997年   1篇
  1996年   1篇
排序方式: 共有3条查询结果,搜索用时 15 毫秒
1
1.
Laser-induced fluorescence (LIF) of pheophorbide-a (Ph-a) was used for imaging of a rat pancreatic tumor. Using a dimensionless function (the ratio of Ph-a fluorescence by bluish autofluorescence), the fluorescence contrasts between excised tumors and their paired pancreas were investigated up to 48 h after a 9 mg kg-1 Ph-a intravenous administration. Among five tested excitation wavelengths, 355 and 610 nm excitations gave the best distinctive contrasts, both 48 h after dye injection. The LIF imaging of six intrapancreatic tumors and six healthy pancreas was carried out in vivo using two laser excitations: 355 nm (Nd:YAG + tripling) for bluish autofluorescence and 610 nm (rhodamine 6G dye) for reddish autofluorescence and dye emission. Images were recorded through bandpass filters at 470 and 640 nm (autofluorescence) and at 680 nm (dye + autofluorescence) with an intensified charged-coupled device camera. Autofluorescence as Ph-a fluorescence images did not allow accurate LIF diagnosis of pancreatic carcinoma. An image processing, including for each pixel a computed division of Ph-a fluorescence (after subtraction of reddish autofluorescence) by bluish autofluorescence intensity generated poorly contrasted tumor images in five of six and false tumor localization in one of three of the tumor-bearing pancreas. A fitting of the digital 640 nm autofluorescence up to the mean 680 nm fluorescence intensity in pancreas prior to subtraction allowed a safe diagnosis to be made with well-contrasted tumor images. To assess automation ability of the processing, a same fitting coefficient (mean of individual values) was applied. In this way, false-negative (one of six) and false-positive (two of six) images were present in tumor-bearing animals as false-positive in one-half of the controls. A successful standardized procedure was then applied with a normalization of 640 and 680 nm pancreas intensities to a same set threshold prior processing. In opposition to thin-layered hollow organs, such as bronchial tube or digestive tract, LIF imaging of carcinoma inserted in a compact organ is exhausting. The use of a dye excitable in the red wavelength range (610 nm for Ph-a) may partly solve this problem, rendering LIF imaging more accurate and potentially automated.  相似文献   
2.
Laser-induced fluorescence of pheophorbide a (Ph- a ) was used for in vitro photodynamic imaging (PDI) of a rat pancreatic acinar tumor. A 400 nm excitation induced a 470 nm autofluorescence and a 678 nm dye fluorescence in tumors and their surrounding pancreas 24 h after a 9 mg kg−1 body weight Ph- a intravenous administration. With lower intensities in these blood-rich tumors than in pancreas, Ph- a fluorescence signals are unable to provide tumor images. A dimensionless function (the ratio of Ph- a fluorescence by autofluorescence, called Rt for the tumor and Rp for the pancreas) was used for fluorescence contrast calculation (C = Rt/Rp) between six tumors and their paired pancreas. Among five available laser excitation wavelengths, only the 355 nm excitation gave a distinctive contrast (C = 1.5). The PDI of six intrapancreatic tumors and their intraperitoneal metastasis and of two control normal pancreas was thus performed ex vivo using a 355 nm excitation source delivered by a tripled Nd: YAG laser and a charged-coupled device camera. Fluorescence images were recorded at 680 nm (dye), 640 nm (background) and 470 nm (autofluorescence) through three corresponding 10 nm width bandpass filters. Computed division for each pixel of Ph- a fluorescence values by autofluorescence generated false color image. In this way, contrasted tumor images were obtained. But in five out of six animals false-positive images were present due to an autofluorescence decrease in some normal pancreatic areas. A 470 nm autofluorescence imaging on the same tumors gave in all cases false-positive image and false-negative in half of the cases. These observations suggest that autofluorescence alone is unable to achieve accurate PDI of pancreatic carcinoma and that using Ph- a as a PDI dye needs strong improvements.  相似文献   
3.
Bose-Einstein condensation (BEC) in a atomic cesium gas prepared in a low field seeker Zeeman sublevel and confined in a magnetic trap has been thwarted by a high cross-section of inelastic spin-flip collisions. A recent experiment [1] succeeded in reaching BEC for cesium atoms using all optical methods and tuning the scattering length. We will discuss a hybrid magnetic and optical trap for cesium atoms in the true hyperfine ground state, the high field seeker Zeeman sublevel, F = m F = 3. Although this trap allows only one-dimensional (1D) evaporative cooling, we show that a route towards BEC with such a trap should be possible. We present simulations of 1D evaporative cooling, which shows that a high phase space density (PSD) of 0.1 could be reached in less than 10 seconds.Received: 25 July 2003PACS: 03.75.Hh Static properties of condensates; thermodynamical, statistical and structural properties - 05.30.Jp Boson systems - 32.80.Pj Optical cooling of atoms; trappingLaboratoire Aimé Cotton is associated with University of Paris-Sud.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号