首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   42篇
  免费   1篇
化学   34篇
晶体学   1篇
物理学   8篇
  2017年   1篇
  2016年   2篇
  2014年   1篇
  2013年   4篇
  2012年   9篇
  2011年   3篇
  2010年   3篇
  2009年   4篇
  2008年   1篇
  2007年   6篇
  2005年   3篇
  2004年   3篇
  2003年   1篇
  2000年   1篇
  1998年   1篇
排序方式: 共有43条查询结果,搜索用时 15 毫秒
1.
Kaul N  Agrawal H  Paradkar AR  Mahadik KR 《Talanta》2004,62(4):843-852
A sensitive, selective, precise and stability-indicating high-performance thin-layer chromatographic method of analysis of nevirapine both as a bulk drug and in formulations was developed and validated. The solvent system consisted of toluene-carbon tetrachloride-methanol-acetone-ammonia (3.5:3.5:2.0:1.0:0.05, v/v/v/v/v). Densitometric analysis of nevirapine was carried out in the absorbance mode at 289nm. This system was found to give compact spots for nevirapine (R(f) value of 0.44+/-0.02). Nevirapine was subjected to acid and alkali hydrolysis, oxidation, dry heat and wet heat treatment and photodegradation. The drug undergoes degradation under acidic, basic conditions and oxidation. Also the degraded products were well resolved from the pure drug with significantly different R(f) values. Linearity was found to be in the range of 30-1000ng/spot with significantly high value of correlation coefficient. The linear regression analysis data for the calibration plots showed good linear relationship with r(2)=0.998+/-0.002 in the working concentration range of 300ng/spot to 1000ng/spot. The mean value of slope and intercept were 0.073+/-0.005 and 36.78+/-1.50, respectively. The method was validated for precision, robustness and recovery. The limit of detection and quantitation were 5 and 10ng/spot, respectively. As the method could effectively separate the drug from its degradation products, it can be employed as a stability indicating one. Moreover, the proposed HPTLC method was utilized to investigate the kinetics of acid degradation process. Arrhenius plot was constructed and activation energy was calculated.  相似文献   
2.
3.
Development of the anticorrosion coatings on metals having both passive matrix functionality and active response to changes in the aggressive environment has raised tremendous interest in material science. Using a sol-gel deposition method, superhydrophobic copper substrate could be obtained. The best hydrophobic coating sol was prepared with methyltriethoxysilane (MTES), methanol (MeOH), and water (as 7 M NH4OH) at a molar ratio of 1:19.1:4.31 respectively. The surface morphological study showed the ball like silica particles distributed on the copper substrate with particle sizes ranging from 8 to 12 μm. The coatings showed the static water contact angle as high as 155° and the water sliding angle as low as 7°. The superhydrophobic nature was maintained even though the deposited copper substrate was soaked for 100 h in 50% of HCl solution. The coatings are stable against humidity and showed superhydrophobic behavior even after 90 days of exposure. The coatings are mechanically stable and water drops maintained the spherical shape on the bent copper substrate, which was bent more than 90°.  相似文献   
4.
The molecular dynamics of new poly (ω‐dodecalactam‐co‐ε‐caprolactam‐co‐propylene oxide) copolymers (DL/CL/PAC) has been investigated by using dynamic mechanical thermal analysis (DMTA) and dielectric relaxation spectroscopy (DRS) measurements. The copolymers were synthesized via anionic polymerization of relevant lactams activated with carbamoyl derivatives of telechelic hydroxyl terminated polypropylene oxide with isophorone diisocyanate (PAC). The calorimetric, X‐ray diffraction, and DMTA measurements were performed to recognize the influence of the composition ratio and the type of PAC on the physical, thermal, and mechanical properties of the synthesized copolymers. The DRS was used to study the frequency dependence of the dielectric permittivity of some isotherms from ?110 to 145 °C. Copolymerization of ε‐caprolactam with about 10 wt % ω‐dodecalactam results in a copolymer that has lower water absorption, a melting point close to that of polyamide 6 and has a high enough degree of crystallinity in respect to high storage modulus. Five dielectric relaxations have been observed in the dielectric spectra, three at lower temperature and two at higher temperature. The copolymers have two glass transition temperatures for polyamide segments and polyether blocks, indicating microphase separation in the copolymers. Other studies directed toward molecular dynamics of polyamide DL/CL/PAC copolymers have not been reported. © 2010 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys, 2010  相似文献   
5.
A facile route to methyltrimethoxysilane (MTMS) based recoverable superhydrophobic silica coatings with dual-scale roughness obtained through the single step base catalyst sol–gel process. Superhydrophobic silica coatings have shown static water contact angle near about 170 ± 1° and dynamic water contact angle up to 2 ± 1°. Superhydrophobic-superhydrophilic switching feature also achieved by alternating heat treatment and bath surface modification with Trimethylchlorosilane (TMCS) at room temperature (26 °C). Furthermore, the superhydrophobic state could be transformed into superhydrophilic state by slow rate heat treatment. These studies present a very simple strategy for the fabrication of recoverable superhydrophobic surfaces.  相似文献   
6.
A simple column chromatographic method has been developed for the separation of thorium(IV) from associated elements using poly-(dibenzo-18-crown-6). The separations are carried out from picric acid medium. The adsorption of thorium(IV) was quantitative from 0.0005–0.05M picric acid. Amongst the various eluents tested, 2.0–8.0M HCl, HBr, 1.0–6.0M HClO4 and 5.0M acetic acid were found to be particularly efficient for the quantitative elution of thorium(IV). The capacity of poly-(dibenzo-18-crown-6) for thorium(IV) was found to be 1.29±0.01 mmol/g of crown polymer. Thorium(IV) was separated from a number of cations in binary mixtures in which most of the cations showed a very high tolerance limit. It was possible to separate thorium(IV) from a number of cations such as lanthanum(III), yttrium(III), uranium(VI), beryllium(II) and barium(II) in multicomponent mixtures. The method was extended to the determination of thorium in monazite sand. It is possible to separate and determine 5 ppm of thorium(IV) by this method. The method is very simple, rapid, selective and has good reproducibility (approximately ±2%).  相似文献   
7.
Two sensitive and reproducible methods are described for the quantitative determination of itopride hydrochloride (IH) in the presence of its degradation products. The first method is based on HPLC separation on a reversed phase Kromasil column [C18 (5-microm, 25 cm x 4.6 mm, ID)] at ambient temperature using a mobile phase consisting of methanol and water (70:30, v/v) adjusted to pH 4.0 with orthophosphoric acid with UV detection at 258 nm. The flow rate was 1.0 mL per min with an average operating pressure of 180 kg/cm2. The second method is based on HPTLC separation on silica gel 60 F254 using toluene:methanol:chloroform:10% ammonia (5.0:3.0:6.0:0.1, v/v/v/v) as mobile phase at 270 nm. The analysis of variance (ANOVA) and Student's t-test were applied to correlate the results of IH determination in dosage form by means of HPLC and HPTLC methods. The drug was subjected to acid and alkali hydrolysis, oxidation, dry heat, wet heat treatment, UV, and photodegradation. The proposed HPLC method was utilized to investigate the kinetics of the acidic, alkaline, and oxidative degradation processes at different temperatures and the apparent pseudo-first-order rate constant, half-life, and activation energy were calculated. In addition the pH-rate profile of degradation of IH in constant ionic strength buffer solutions in the pH range 2-11 was studied.  相似文献   
8.
Isocratic reversed phase high performance liquid chromatographic (HPLC) method using RP C18 column was developed for simultaneous determination of the curcuminoids. Mobile phase consisted of acetonitrile:0.1% trifluro-acetic acid (50:50) and flow rate was 1.5 mL min−1 and elution was monitored at 420 nm. Validation in selected conditions showed that the chosen method is sensitive, selective, precise and reproducible with linear response of detector for the simultaneous determination of curcumin (C), demethoxycurcumin (DMC) and bis-demethoxycurcumin (BDMC). The limits of detection were 27.99, 31.91 and 21.81 ng mL−1 for C, DMC and BDMC, respectively. Limits of quantitation for C, DMC and BDMC, were 84.84, 96.72 and 66.10 ng mL−1, respectively. Linear range was form 100 to 600 ng mL−1. The mean ± SD percent recoveries of curcuminoids were 99.87 ± 0.34, 100.09 ± 0.48 and 100.10 ± 0.60% of C, DMC and BDMC, respectively. Further, the method was used for quantitation of curcuminoids from turmeric rhizome.  相似文献   
9.
10.
Two chromatographic techniques are described for the separation and quantitative determination of azadirachtin A and B, salannin, and nimbin present in the crude extract of neem seed kernels and commercial neem based formulations. The high performance thin-layer chromatography (HPTLC) separation of markers was carried out on Merck TLC aluminium sheets of silica gel 60 F254 using ethylacetate-benzene (7.0: 3.0, v/v) as mobile phase. The other technique was based on extended length packed column supercritical fluid chromatographic (PC-SFC) separation of the markers using Cyano column (250 mm × 4.6 mm I.D, S-5.0 μ) and Kromasil 100 NH2 column (250 mm × 4.6 mm I.D, 5.0 μ) connected in series. The detection was carried out using photodiode array detector at 338 K using methanol-modified carbon dioxide (10%) as the mobile phase at flow rate of 2.0 mL min−1. The current study assesses the effect of extending column length during PC-SFC experiment to obtain maximum resolution between a number of unknown components and known markers present in neem seed extracts. Both the chromatographic methods were validated in terms of precision, robustness, recovery, limits of detection and quantitation. The analysis of variance (ANOVA) and Student’s t-test were applied to correlate the results of quantitative determination of markers by means of HPTLC and PC-SFC method.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号