排序方式: 共有9条查询结果,搜索用时 125 毫秒
1
1.
Gabriela Ionita Petre Ionita Victor EM. Sahini Constantin Luca 《Journal of inclusion phenomena and macrocyclic chemistry》2001,39(3-4):269-271
The kinetics of oxidation of amino acids (Arg, His, Lys, Phe, Thr and Tyr), a dipeptide (Gly-His), and BSA (bovine serum albumin) by two persistent water soluble free radicals of the hydrazyl type has been studied.The rate decreases in the order Arg>Lys>Tyr>Thr>HisBSAPheGly-His with bothfree radicals. Addition to the reaction mixture of - and -cyclodextrin decreases the oxidation rate, probably due to amino acidencapsulation in the cyclodextrin cavity. -Cyclodextrin protects more efficiently against oxidation than -cyclodextrin. 相似文献
2.
3.
4.
We have used a variety of microscopic techniques to reveal the structure and motion of flux line arrangements, when the flux
lines in low T
c type II superconductors are caused to move by a transport current. Using small-angle neutron scattering by the flux line
lattice (FLL), we are able to demonstrate directly the alignment by motion of the nearest-neighbor FLL direction. This tends
to be parallel to the direction of flux line motion, as had been suspected from two-dimensional simulations. We also see the
destruction of the ordered FLL by plastic flow and the bending of flux lines. Another technique that our collaboration has
employed is the direct measurement of flux line motion, using the ultra-high-resolution spectroscopy of the neutron spin-echo
technique to observe the energy change of neutrons diffracted by moving flux lines. The muon spin rotation (μSR) technique gives the distribution of values of magnetic field within the FLL. We have recently succeeded in performing
μSR measurements while the FLL is moving. Such measurements give complementary information about the local speed and orientation
of the FLL motion. We conclude by discussing the possible application of this technique to thin film superconductors. 相似文献
5.
Lunderberg E DeYoung PA Kohley Z Attanayake H Baumann T Bazin D Christian G Divaratne D Grimes SM Haagsma A Finck JE Frank N Luther B Mosby S Nagi T Peaslee GF Schiller A Snyder J Spyrou A Strongman MJ Thoennessen M 《Physical review letters》2012,108(14):142503
Evidence for the ground state of the neutron-unbound nucleus (26)O was observed for the first time in the single proton-knockout reaction from a 82 MeV/u (27)F beam. Neutrons were measured in coincidence with (24)O fragments. (26)O was determined to be unbound by 150(-150)(+50) keV from the observation of low-energy neutrons. This result agrees with recent shell-model calculations based on microscopic two- and three-nucleon forces. 相似文献
6.
KM Clauwaert Van Bocxlaer JF HJ Major JA Claereboudt WE Lambert Van den Eeckhout EM Van Peteghem CH De Leenheer AP 《Rapid communications in mass spectrometry : RCM》1999,13(14):1540-1545
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
7.
Christian G Frank N Ash S Baumann T Bazin D Brown J DeYoung PA Finck JE Gade A Grinyer GF Grovom A Hinnefeld JD Lunderberg EM Luther B Mosby M Mosby S Nagi T Peaslee GF Rogers WF Smith JK Snyder J Spyrou A Strongman MJ Thoennessen M Warren M Weisshaar D Wersal A 《Physical review letters》2012,108(3):032501
The technique of invariant mass spectroscopy has been used to measure, for the first time, the ground state energy of neutron-unbound (28)F, determined to be a resonance in the (27)F+n continuum at 220(50) keV. States in (28)F were populated by the reactions of a 62 MeV/u (29)Ne beam impinging on a 288 mg/cm(2) beryllium target. The measured (28)F ground state energy is in good agreement with USDA/USDB shell model predictions, indicating that pf shell intruder configurations play only a small role in the ground state structure of (28)F and establishing a low-Z boundary of the island of inversion for N=19 isotones. 相似文献
8.
Clauwaert KM Van Bocxlaer JF Major HJ Claereboudt JA Lambert WE Van den Eeckhout EM Van Peteghem CH De Leenheer AP 《Rapid communications in mass spectrometry : RCM》1999,13(14):1540-1545
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
9.
Spyrou A Kohley Z Baumann T Bazin D Brown BA Christian G DeYoung PA Finck JE Frank N Lunderberg E Mosby S Peters WA Schiller A Smith JK Snyder J Strongman MJ Thoennessen M Volya A 《Physical review letters》2012,108(10):102501
We report on the first observation of dineutron emission in the decay of 16Be. A single-proton knockout reaction from a 53 MeV/u 17B beam was used to populate the ground state of 16Be. 16Be is bound with respect to the emission of one neutron and unbound to two-neutron emission. The dineutron character of the decay is evidenced by a small emission angle between the two neutrons. The two-neutron separation energy of 16Be was measured to be 1.35(10) MeV, in good agreement with shell model calculations, using standard interactions for this mass region. 相似文献
1