首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   45篇
  免费   1篇
化学   31篇
数学   1篇
物理学   14篇
  2016年   1篇
  2013年   1篇
  2011年   3篇
  2010年   1篇
  2006年   1篇
  2004年   4篇
  2003年   2篇
  2002年   2篇
  2001年   2篇
  2000年   4篇
  1999年   4篇
  1998年   2篇
  1996年   1篇
  1992年   3篇
  1991年   3篇
  1990年   1篇
  1989年   1篇
  1988年   4篇
  1987年   6篇
排序方式: 共有46条查询结果,搜索用时 343 毫秒
1.
2.
3.
4.
5.
6.
A new approach has been developed and tested for the urgent analysis of dioxins in samples of air-dust filters originating from catastrophe emissions. The procedure consists of a fast extraction of the sample with microwave solvent extraction (MASE) and acetone as solvent followed by a fast cleanup of the extract with normal phase coupled column liquid chromatography (LC/LC).

The multi-dimensional LC/LC system employs a 50 mm×4.6 mm i.d. column packed with 3 μm silica and a 150 mm×4.6 mm i.d. column packed with 5 μm PYE as the first and second analytical column, respectively. Iso-hexane is used on both columns to perform cleanup and dichloromethane to perform efficient back-flush elution of the compounds from the second column. The obtained polarity-based separation in the first dimension and molecular-structure based separation in the second dimension provides a fast and powerful cleanup.

Validation was done by analysing samples of homemade RIVM air-dust with aged residues (n=8, spiking level about 15 pg mg−1 per compound) of dioxins/furans and samples of reference Urban Dust SRM 1649a (n=4) with both the new approach and the existing conventional procedure and were instrumentally analyzed with capillary gas chromatography and high resolution mass spectrometric detection (GC/HRMS).

In comparison to the existing conventional procedure, the new approach reduces sample processing from several days to several hours per sample.

As regards the aged-residue air-dust samples, the new method shows a good accuracy, precision and high selectivity providing a performance in good agreement with the existing procedure. In SRM air-dust, the concentration of a few compounds obtained by the new method was below (10–50%) the certified value.  相似文献   

7.
The coupled-column (LC-LC) configuration consisting of a 3 microm C18 column (50 x 4.6 mm I.D.) as the first column and a 5 microm C18 semi-permeable-surface (SPS) column (150 x 4.6 mm I.D.) as the second column appeared to be successful for the screening of acidic pesticides in surface water samples. In comparison to LC-LC employing two C18 columns, the combination of C18/SPS-C18 significantly decreased the baseline deviation caused by the hump of the co-extracted humic substances when using UV detection (217 nm). The developed LC-LC procedure allowed the simultaneous determination of the target analytes bentazone and bromoxynil in uncleaned extracts of surface water samples to a level of 0.05 microg/l in less than 15 min. In combination with a simple solid-phase extraction step (200 ml of water on a 500 mg C18-bonded silica) the analytical procedure provides a high sample throughput. During a period of about five months more than 200 ditch-water samples originating from agricultural locations were analyzed with the developed procedure. Validation of the method was performed by randomly analyzing recoveries of water samples spiked at levels of 0.1 microg/l (n=10), 0.5 microg/l (n=7) and 2.5 microg/l (n=4). Weighted regression of the recovery data showed that the method provides overall recoveries of 95 and 100% for bentazone and bromoxynil, respectively, with corresponding intra-laboratory reproducibilities of 10 and 11%, respectively. Confirmation of the analytes in part of the samples extracts was carried out with GC-negative ion chemical ionization MS involving a derivatization step with bis(trifluoromethyl)benzyl bromide. No false negatives or positives were observed.  相似文献   
8.
In the development of a screening method for the determination of residues of mecoprop in soils involving coupled-column RPLC-UV (228 nm) the cleanup performance of a 5 μm GFF-II internal surface reversed phase (ISRP, Pinkerton) analytical column (50 × 4.6 mm I.D.) as a first column was investigated. In comparison to an analytical C18 column the ISRP column substantially improved the separation between acidic analyte and co-extracted humic substances. Under the selected coupled-column conditions soil extracts obtained after hydrolysis with an aqueous alkaline solution, acidifying and centrifugation could be analyzed directly allowing the determination of mecoprop in soils to a level of about 0.02 mg/kg. A rapid concentration step on a 100 mg C18 solid phase extraction (SPE) cartridge was adopted into the procedure providing a limit of detection (S/N = 3) of 0.01 mg/kg of mecoprop in soil. The method was validated by analyzing freshly spiked soil samples and samples with aged residues. In case of freshly spiked samples the overall recovery was 87% (n = 18, spiked level 0.02–8.0 mg/kg) with a repeatability of 6.8% and a reproducibility of 8.3%. No significant decrease of the recovery was observed for samples with aged residues (n = 15, spiked level 0.1 and 8.0 mg/kg) during a storage of 29 days in the refrigerator at about 4?°C; a storage of 67 days provided a mean recovery of 76% (n = 14, spiked level 8.0 mg/kg).  相似文献   
9.
The potential of solid-phase extraction coupled on-line to liquid chromatography/electrospray tandem mass spectrometry (SPE-LC-ESI-MS/MS) has been investigated in this paper for the efficient sensitive quantification and confirmation of 16 antibiotics in water. The list of targeted analytes included 10 quinolones (oxolinic acid (OXO), nalidixic acid (NAL), flumequine (FLU), marbofloxacine (MAR), ofloxacine (OFLO), enrofloxacine (ENR), pefloxacine (PEF), ciprofloxacine (CIP), pipemidic acid (PIPE), norfloxacine (NOR)) and 6 penicillins (penicillin G (PEN), oxacillin (OXA), dicloxacillin (DIC), piperacillin (PIP), cloxacillin (CLO) and ampicillin (AMP)) that were determined in ground and surface water. The procedure is based on the injection of 9.8 mL of sample into the SPE-LC-MS/MS system and the measurement of antibiotics by selected reaction monitoring mode, using a triple quadrupole analyser. The method has been validated at realistic low concentrations that might be present in environmental water, i.e. 10 and 100 ng L(-1), obtaining recoveries between 74% and 123% with relative standard deviation lower than 14%. Matrix effects were not relevant in most of cases, except for ampicillin in surface water, where notable signal suppression was observed. The limits of detection were as low as 0.4-4.3 ng L(-1). The method developed allows the rapid screening and quantification of all the analytes selected by acquiring one MS/MS transition (normally the most sensitive) for each compound. It was applied to a number of actual surface and groundwater samples with several compounds being detected, mainly quinolones, at low ng L(-1) levels. Special attention was given to the confirmation of compounds detected in water due to the difficulties of obtaining confident confirmation at low ng L(-1). This matter has been of growing concern in the last few years as reflected by recent papers and correspondence. The acquisition of several MS/MS transitions for each compound detected in a second independent analysis allowed the unequivocal confirmation of identity, avoiding reporting false-positives. Finally, the potential of QTOF instruments to confirm positive samples has also been evaluated and compared with triple quadrupole analysers.  相似文献   
10.
Electrospray mass spectrometry/mass spectrometry was used to investigate the gas‐phase properties of protonated expanded porphyrins, in order to correlate those with their structure and conformation. We have selected five expanded meso‐pentafluorophenyl porphyrins, respectively, a pair of oxidized/reduced fused pentaphyrins (22 and 24 π electrons), a pair of oxidized/reduced regular hexaphyrins (26 and 28 π electrons) and a regular doubly N‐fused hexaphyrin (28 π electrons). The gas‐phase behavior of the protonated species of oxidized and reduced expanded porphyrins is different. The oxidized species (aromatic Hückel systems) fragment more extensively, mainly by the loss of two HF molecules. The reduced species (Möbius aromatic or Möbius‐like aromatic systems) fragment less than their oxidized counterparts because of their increased flexibility. The protonated regular doubly fused hexaphyrin (non‐aromatic Hückel system) shows the least fragmentation even at higher collision energies. In general, cyclization through losses of HF molecules decreases from the aromatic Hückel systems to Möbius aromatic or Möbius‐like aromatic systems to non‐aromatic Hückel systems and is related to an increase in conformational distortion. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号