排序方式: 共有37条查询结果,搜索用时 31 毫秒
1.
2.
Ibtissam Elaaraj Safae ER. Raouan Asmae Nakkabi Bouchra Es-sounni Ibnsouda Koraichi Noureddine El moualij Mohammed Fahim 《印度化学会志》2022,99(5):100404
New metal complexes of (Zn(II), Co(II), Ni(II) and Cu(II)) based on the ligand 2-(thiophen-2-yl)-1-(thiophen-2-ylmethyl)-1H-benzo[d]imidazole] were synthesized, whose structures were determined with the different spectroscopic techniques 1H NMR,13C NMR, FT-IR, UV–Visible and by mass spectrometry. The thermal analysis was performed by TG-DTA. The antioxidant activity of the ligand and its complexes was evaluated by DPPH (2,2-diphenyl-1-picrylhydrazyl) method, in comparison with the synthetic antioxidant, ascorbic acid. The results obtained showed that the antioxidant activity of the ligand and its complexes is moderate and that the copper complex has a high activity that exceeds that of ascorbic acid. Antimicrobial activity of the ligand and its metal complexes was studied against two Gram-positive bacteria: Bacillus subtilis ILP1428B, Staphylococcus aureus CIP543154 and two Gram-negative bacteria: Pseudomonas aeruginosa ATCC27653, Escherichia coli CIP5412 (American Type Culture Collection)the activity data show that the metal complexes are more potent than the free ligand. 相似文献
3.
4.
Detectability of a tonal signal added to a tonal masker increases with increasing duration ("temporal integration"), up to some maximum duration. Initially assumed to be some form of energy integration over time, this phenomenon is now often described as the result of a statistical "multiple looks" process. For continuous maskers, listeners may also use a mechanism sensitive to changes in stimulus intensity, possibly a result of inherent sensitivity to amplitude modulation (AM). In order to examine this hypothesis, change detection was investigated in the presence of AM maskers presented at either the same carrier frequency as the target signal or at a distant frequency. The results are compatible with the hypothesis that listeners detect intensity increments by using change-detection mechanisms (modeled here as the outputs of a bank of modulation filters) sensitive to envelope modulation at both low (4-16 Hz) and high (around 100 Hz) rates. AM masking occurred even when the masker was at a carrier frequency more than two octaves above that of the signal to be detected. This finding is also compatible with the hypothesis that similar mechanisms underlie sensitivity to AM (where across-frequency masking is commonly shown) and detection of intensity increments. 相似文献
5.
固相萃取-毛细管柱气相色谱-质谱测定土壤和蔬菜中三唑酮残留量 总被引:3,自引:0,他引:3
提出固相萃取分离,毛细管柱气相色谱和质谱联用法测定土壤及蔬菜中三唑酮的残留量.试样用乙腈提取,所得提取液在80℃吹氮至近干,并加正己烷2 mL溶解残渣.此溶液流经填充酸性氧化铝的固相萃取小柱,用正己烷-丙酮(2+1)混合溶剂淋洗小柱,使土壤样品中存在的硫磺与需测定的三唑酮分离.用正己烷一丙酮(1+3)混合溶剂将三唑酮从小柱上解吸洗下,所得洗出液蒸发浓缩,用正己烷定容为5.0 mL供GC-MS分析用.测定中用三唑酮标准溶液制备浓度范围在0.006~1.44 mg·L-1之间的标准曲线.方法的检出限(3S/N)为0.001 mg·kg-1.在3个浓度水平上对方法的回收及精密度作了试验,测得其回收率及相对标准偏差(n=5)依次在84%~92 9,5及1.93%~4.04%之间. 相似文献
6.
Listeners detected interaural differences of time in trains of high-frequency clicks. The manipulated variables were the number of clicks in the train and the period between clicks. Thresholds were compared to an optimal integrator, where the binaural information accrued from each click in the stimulus train is equivalent. In agreement with data reported in the past, integration is optimal only when the period between clicks exceeds approximately 10 ms and when the duration of the entire stimulus train is less than about 250 ms. The first constraint represents a limitation due to a form of "binaural adaptation" and the second is due to a limited "integration period." 相似文献
7.
ER Badman GE Patterson JM Wells RE Santini RG Cooks 《Journal of mass spectrometry : JMS》1999,34(8):889-894
Dual-detector differential non-destructive Fourier transform detection in a quadrupole ion trap is shown to improve signal intensity and reduce noise compared with spectra recorded using a single detector. A larger area detector in each end-cap electrode is machined to fit its hyperbolic shape and so minimize field imperfections on the z-axis. Argon, acetophenone and bromobenzene spectra were recorded to allow a comparison between single- and dual-detector (differential) modes of detection and to demonstrate the improvement achieved with differential detection. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
8.
IntroductionFrontalchromatography (FC) ,anoldbranchinliquidchromatography (LC) ,1hasbeensuccessfullyem ployedinthesolutionofmanytheoreticalaswellasap pliedproblems—suchasmeasuringbindingconstantbe tweencomponents2 andkineticparametersofchemicalreactions ,3 ads… 相似文献
9.
本文设计了染料循环再生的光敏反应体系, 通过对占吨碘翁盐电子反应机制的深入研究, 提出了占吨染料在光敏反应过程中的染料再生循环, 它依次由三个反应过程组成: 在光作用下, 通过电子转移反应, 产生染料氧化褪色体(I); 在H给体存在下, 通过H转移反应, 使产物(I)转化为染料酸式隐色体(II); 在碱作用下, (II)发生去质子反应, 染料再生回复到染料的起始结构。其中光、H给体和碱的作用是再生循环的三个要素, 而控制染料酸式隐色体生成比例是染料再生效率的关键。由乙基曙红碘翁盐/三乙胺组成的染料再生体系的染料敏化效率比单一体系高4倍左右, 同时使活性自由基的数量增殖, 这种体系在实际应用方面具有重要意义。 相似文献
10.
A set of experiments was conducted to examine the loudness of sounds with temporally asymmetric amplitude envelopes. Envelopes were generated with fast-attack/slow-decay characteristics to produce F-S (or "fast-slow") stimuli, while temporally reversed versions of these same envelopes produced corresponding S-F ("slow-fast") stimuli. For sinusoidal (330-6000 Hz) and broadband noise carriers, S-F stimuli were louder than F-S stimuli of equal energy. The magnitude of this effect was sensitive to stimulus order, with the largest differences between F-S and S-F loudness occurring after exposure to a preceding F-S stimulus. These results are not compatible with automatic gain control, power-spectrum models of loudness, or predictions obtained using the auditory image model [Patterson et al., J. Acoust. Soc. Am. 98, 1890-1894 (1995)]. Rather, they are comparable to phenomena of perceptual constancy, and may be related to the parsing of auditory input into direct and reverberant sound. 相似文献