排序方式: 共有38条查询结果,搜索用时 31 毫秒
1.
2.
Moldovan L Melinte S Bayot V Papadakis SJ De Poortere EP Shayegan M 《Physical review letters》2000,85(20):4369-4372
We report very low temperature ( T) thermopower and resistivity ( rho) measurements on variable-density, two-dimensional hole systems confined to GaAs quantum wells. As the hole density is lowered from 1.49x10(11) cm(-2) to 0.14x10(11) cm(-2), the system crosses from an insulating ( drho / dT less, similar0) to a metallic regime ( drho / dT>0) and finally displays insulating behavior ( drho / dT<0). Diffusion thermopower shows a striking sign reversal in a narrow range of density in the metallic regime, suggesting a qualitative change in the conduction or the scattering mechanism. 相似文献
3.
D. O'Sullivan H. Oestermann P. S. Macmahon L. N. Srivastava J. R. Stubbs N. Mainsbrecq Vivario Stainier M. Schnetka Th. Forgács M. F. Bengen E. Bohm W. Plücker M. Klimmer H. Haupt F. Borchers A. I. Burstein F. S. Frum Orla-Jensen M. O. Winther H. Damen H. A. Sirks Th. v. Fellenberg 《Analytical and bioanalytical chemistry》1936,104(11-12):453-458
4.
SISCOM is a library search system for mass spectrometry which is based on a new method of coding spectra by selecting the most important peaks within homologous ion series, and on a multiple factor assessment of the result. Examples demonstrate the ability of the system to identify various compounds, even from mixtures or by reference spectra which differ from those measured. SISCOM is especially suitable for detecting structural similarities like common substructures, even in cases where no similarity can be recognized by visual comparison of patterns or by human interpretation of the spectrum. 相似文献
5.
Capillary polystyrene-divinylbenzene (PS-DVB) monolithic columns were used to separate differentially acetylated intact IM9 protein isoforms. Compared to the unmodified form, the hydrophobic shift for intact acetylated isoforms was significant under standard reversed-phase conditions (32.5-45% acetonitrile in 10 min). The high chromatographic resolution of the PS-DVB monolithic columns resulted in peak widths at half height of 4-5s. This allowed us to nearly completely resolve a number of peaks greater than the number of possible acetylation sites. This observation suggested that not only the number, but also the location of the acetylations on the protein had a significant effect on the retention. Matrix-assisted laser desorption ionization time-of-flight MS and MS/MS were used to confirm the chromatographic separation of isoforms. It was found that the acetylations site, especially on the N-terminus, has an effect on the retention on the PS-DVB column. 相似文献
6.
EP Sheretov VS Gurov MV Dubkov OV Korneeva 《Rapid communications in mass spectrometry : RCM》1999,13(16):1699-1702
In this article we compare the classical monopole mass filter of von Zahn and the monopole mass filter with a hyperbolic V-shaped electrode. The experimental results and those of computer simulation for both mass spectrometers are presented. We show that the replacement of a conventional 90 degrees V-shaped electrode by an electrode with a hyperbolic profile substantially improves the peak shape of any given mass, and increases the mass resolution by a factor of 3-4 and the abundance sensitivity by a factor of 100. The potential of high analytical performance combined with electroforming techniques for electrode manufacture indicate future practical uses of such instruments. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
7.
8.
9.
10.
Carola W. N. Damen Hilde Rosing Jan H. M. Schellens Jos H. Beijnen 《Analytical and bioanalytical chemistry》2009,394(4):1171-1182
A sensitive, specific and efficient high-performance liquid chromatography-tandem mass spectrometry assay for the simultaneous
determination of vincristine and actinomycin-D in human dried blood spots is presented. Dried blood spots were punched out
of a collection paper with a 0.25-in.-diameter punch. The analytes were extracted from the punched-out disc using sonication
during 15 min in a mixture of acetonitrile–methanol–water (1:1:1, v/v/v) containing the internal standard vinorelbine. Twenty-microlitre volumes were injected onto the HPLC system. Separation was
achieved on a 50 × 2.1 mm ID Xbridge C18 column using elution with 1 mM ammonium acetate–acetonitrile (70:30, v/v) adjusted to pH 10.5 with ammonia and run in a gradient with methanol at a flow rate of 0.4 mL/min. HPLC run time was 6 min.
The assay quantifies vincristine from 1 to 100 ng/mL and actinomycine-D from 2 to 250 ng/mL using a blood sample obtained
by a simple finger prick. Validation results demonstrate that vincristine and actinomycin-D can be accurately and precisely
quantified in human dried blood spots with the presented method. The assay can now be used to support clinical pharmacologic
studies with vincristine and actinomycin-D. 相似文献