排序方式: 共有45条查询结果,搜索用时 0 毫秒
1.
Martin E. Schimpf J. Calvin Giddings 《Journal of Polymer Science.Polymer Physics》1989,27(6):1317-1332
The thermal diffusion coefficient DT has been obtained for 17 polymer-solvent combinations, each of them spanning a range of polymer molecular weights, using thermal field-flow fractionation. The polymers examined include polystyrene, poly(alpha-methyl)styrene, polymethylmethacrylate, and polysioprene. The solvents include benzene, toluene, ethylbenzene, tetrahydrofuran, methylethylketone, ethylacetate, and cyclohexane. Although DT was confirmed as essentially independent of polymer molecular weight, it was found to vary substantially with the chemical composition of polymer and solvent. The results were used to evaluate several thermal diffusion theories; the agreement with theory was generally found to be unsatisfactory. Attempts were then made to correlate the measured thermal diffusion coefficients with various physicochemical parameters of the polymers and solvent. A good correlation was found in which DT increases with the thermal conductivity difference of the polymer and solvent and varies inversely with the activation energy of viscous flow of the solvent. 相似文献
2.
3.
Röser F Schimpf D Schmidt O Ortaç B Rademaker K Limpert J Tünnermann A 《Optics letters》2007,32(15):2230-2232
We report on an ytterbium-doped fiber based chirped-pulse amplification system delivering 100 microJ pulse energy at a repetition rate of 900 kHz, corresponding to an average power of 90 W. The emitted pulses are as short as 500 fs. To the best of our knowledge, this is the highest average power ever reported for high-energy femtosecond solid-state laser systems. 相似文献
4.
Electromagnetic and nuclear fission of238U in the reaction of 100, 500, and 1000 A·MeV208Pb with238U
S. Polikanov W. Brüchle H. Folger E. Jäger T. Krogulski M. Schädel E. Schimpf G. Wirth T. Aumann J. V. Kratz E. Stiel N. Trautmann 《Zeitschrift für Physik A Hadrons and Nuclei》1994,350(3):221-227
The folding- and azimuthal-angle and velocity distributions for the238U fission fragments have been measured in reactions with 100, 500, and 1000 A·MeV208Pb. These distributions were used to decompose the fission cross section into its electromagnetic and nuclear components. The fraction of electromagnetic fission was found to be 0.16±0.07, 0.48±0.08, and 0.60±0.04, respectively. The electromagnetic fission cross section as a function of the208Pb nucleus energy is compared with theoretical predictions. The measured fission cross section from nuclear reactions (≈1.5 b) is approximately constant between 100 and 1000 A·MeV. 相似文献
5.
6.
Grant DM Elson DS Schimpf D Dunsby C Requejo-Isidro J Auksorius E Munro I Neil MA French PM Nye E Stamp G Courtney P 《Optics letters》2005,30(24):3353-3355
We demonstrate an optically sectioned fluorescence lifetime imaging microscope with a wide-field detector, using a convenient, continuously tunable (435-1150 nm) ultrafast source for fluorescence imaging applications that is derived from a visible supercontinuum generated in a microstructured fiber. 相似文献
7.
D. Nodop D. Schimpf J. Limpert A. T��nnermann 《Applied physics. B, Lasers and optics》2011,102(4):737-741
We propose and investigate a high power superluminescence diode (SLD) as a pulsed seed source for a highly dynamic and versatile pulse fiber amplifier system. The SLD provides, contrary to conventional Fabry?CPérot laser diodes, a smooth and broad output spectrum which is independent of the input pulse parameters. The output pulses from the SLD are as short as 10?ns with up to 150?mW peak power. Moreover, the pulses can be directly shaped by modulating the injection current of the SLD. Pulse shaping in an amplifier configuration is demonstrated without the observation of stimulated Brillouin scattering (SBS) due to the provided spectral bandwidth of 10?nm FWHM. Further spectral shaping was realized with a band pass filter in the amplifier chain. 相似文献
8.
We analyze the material transport equations (MTE) derived by Eslamian and co-authors and address the criticism expressed regarding the approach formulated in our previous work. In doing so, we show that the MTE formulated by Eslamian and co-authors are valid only in closed stationary non-isothermal systems in combination with the restrictions on the Onsager coefficients formulated in our work which is criticized, and that for non-stationary systems the approach we took can be used. 相似文献
9.
We demonstrate polarization-sensitive measurement of the modal content of waveguides by generalizing the classic rotating wave-plate-based polarimeter to wide-field optical low-coherence interferometry. The spatial phases of the modes are retrieved with principal component analysis. By applying this polarization-sensitive cross-correlation (C2) imaging technique to the characterization of a few-mode fiber, we reveal that different modes experience distinct bend-induced birefringence in optical fibers. This polarization-resolved C2 imaging is well suited for analyzing the impact of polarization on wave propagation in high-power fiber lasers as well as in mode-division-multiplexed communications systems. 相似文献
10.
Quantification of myo‐inositol, 1,5‐anhydro‐ D‐sorbitol,and D‐chiro‐inositol using high‐performance liquid chromatography with electrochemical detection in very small volume clinical samples 下载免费PDF全文
Karen J. Schimpf Claudia C. Meek Richard D. Leff Dale L. Phelps Daniel J. Schmitz Christopher T. Cordle 《Biomedical chromatography : BMC》2015,29(11):1629-1636
Inositol is a six‐carbon sugar alcohol and is one of nine biologically significant isomers of hexahydroxycyclohexane. Myo‐inositol is the primary biologically active form and is present in higher concentrations in the fetus and newborn than in adults. It is currently being examined for the prevention of retinopathy of prematurity in newborn preterm infants. A robust method for quantifying myo‐inositol (MI), D ‐chiro‐inositol (DCI) and 1,5‐anhydro‐ D ‐sorbitol (ADS) in very small‐volume (25 μL) urine, blood serum and/or plasma samples was developed. Using a multiple‐column, multiple mobile phase liquid chromatographic system with electrochemical detection, the method was validated with respect to (a) selectivity, (b) accuracy/recovery, (c) precision/reproducibility, (d) sensitivity, (e) stability and (f) ruggedness. The standard curve was linear and ranged from 0.5 to 30 mg/L for each of the three analytes. Above‐mentioned performance measures were within acceptable limits described in the Food and Drug Administration's Guidance for Industry: Bioanalytical Method Validation. The method was validated using blood serum and plasma collected using four common anticoagulants, and also by quantifying the accuracy and sensitivity of MI measured in simulated urine samples recovered from preterm infant diaper systems. The method performs satisfactorily measuring the three most common inositol isomers on 25 μL clinical samples of serum, plasma, milk, and/or urine. Similar performance is seen testing larger volume samples of infant formulas and infant formula ingredients. MI, ADS and DCI may be accurately tested in urine samples collected from five different preterm infant diapers if the urine volume is greater than 2–5 mL. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献