首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   9篇
  免费   0篇
  国内免费   2篇
化学   3篇
综合类   1篇
数学   2篇
物理学   5篇
  2023年   1篇
  2022年   1篇
  2019年   1篇
  2013年   1篇
  2012年   1篇
  2011年   1篇
  2010年   1篇
  2008年   1篇
  2006年   1篇
  2003年   1篇
  1999年   1篇
排序方式: 共有11条查询结果,搜索用时 31 毫秒
1.
采用沉淀法制备前驱体,通过不同温度合成了上转换发光材料Y2O2S∶Er3+,Yb3+,运用XRD,SEM和上转换发射光谱对其进行表征。结果表明,所合成的Y2O2S∶Er3+Yb3+属于六方晶系晶体,随着合成温度的升高,产物的粒径不断增大,上转换发射光强度逐渐增加。研究Y2O2S∶Er3+Yb3+的上转换发光过程,红光发射和绿光发射分别源于Er3+离子的4F9/2→4I15/2以及2H11/2→4I15/2,4S3/2→4I15/2能级跃迁。利用群论计算了晶场中Er3+离子的能级分裂数目。  相似文献   
2.
To assess the reproducibility of quantitative measurements of cartilage morphology and trabecular bone structure of the knee at 7 T, high-resolution sagittal spoiled gradient-echo images and high-resolution axial fully refocused steady-state free-precession (SSFP) images from six healthy volunteers were acquired with a 7-T scanner. The subjects were repositioned between repeated scans to test the reproducibility of the measurements. The reproducibility of each measurement was evaluated using the coefficient(s) of variation (CV). The computed CV were 1.13% and 1.55% for cartilage thickness and cartilage volume, respectively, and were 2.86%, 1.07%, 2.27% and 3.30% for apparent bone volume over total volume fraction (app.BV/TV), apparent trabecular number (app.Tb.N), apparent trabecular separation (app.Tb.Sp) and apparent trabecular thickness (app.Tb.Th), respectively. The results demonstrate that quantitative assessment of cartilage morphology and trabecular bone structure is reproducible at 7 T and motivates future musculoskeletal applications seeking the high-field strength's superior signal-to-noise ratio.  相似文献   
3.
本文主要研究如下含非线性梯度项的非强制拟线性椭圆方程\begin{equation*}\left \{\begin{array}{rl}-\text{div}(\frac{|\nabla u|^{p-2}\nabla u}{(1+|u|)^{\theta(p-1)}})+\frac{|u|^{p-2}u|\nabla u|^{p}}{(1+|u|)^{\theta p}}=\mu,~&x\in\Omega,\\ u=0,~&x\in\partial\Omega,\end{array}\right.\end{equation*} 弱解的存在性和不存在性, 其中$\Omega\subseteq\mathbb{R}^N(N\geq3)$ 是有界光滑区域, $1相似文献   
4.
In many cases, initial release of drugs from microparticles is undesirable. In the present study, Pluronic®F127, which shows thermosensitive characteristic, was used for controlling both the initial release and the sustained release of insulin from microspheres. Calcium-alginate insulin microspheres were prepared by emulsion technology and dispersed in a thermosensitive semisolid gel, the PF127. In vitro study demonstrated that PF127 could protect the activity of insulin in some extent and control the initial release and sustained release of insulin well. The results of in vivo hypoglycemic experiment carried out on diabetic rats also displayed a well correlation with in vitro release patterns. The results suggested that PF127 could sustain insulin release through a subcutaneous injection, and this material was available to deliver insulin aiming for prolonged and smooth hypoglycemic function.  相似文献   
5.
P. JÓVÁRI 《Molecular physics》2013,111(11):1149-1156
The structure factor of liquid CS2 has been measured at ambient temperature by the 7C2 diffractometer at the Laboratoire Leon Brillouin?, Saclay, France. The result has been modelled by the reverse Monte Carlo (RMC) method. The only reported neutron diffraction measurement on liquid CSe2 has also been investigated in detail. In both cases initial configurations for the RMC runs have been obtained by molecular dynamics simulation using a simple soft sphere potential. It has been found that the main features of experimental results have been reproduced even by this choice suggesting that the structure of these systems is almost entirely described by the excluded volume. Examination of model size dependence of results has also been carried out revealing the importance of using large simulation boxes.  相似文献   
6.

Purpose

A direct correlation between T, T2 and quantified proteoglycan and collagen contents in human osteoarthritic cartilage has yet to be documented. We aimed to investigate the orientation effect on T and T2 values in human osteoarthritic cartilage and to quantify the correlation between T, T2 vs. biochemical composition and histology in human osteoarthritic cartilage.

Materials and methods

Thirty-three cartilage specimens were collected from patients who underwent total knee arthroplasty due to severe osteoarthritis and scanned with a 3T MR scanner for T and T2 quantification. Nine specimens were scanned at three different orientations with respect to the B0: 0°, 90° and 54.7°. Core punches were taken after MRI. Collagen and proteoglycan contents were quantified using biochemical assays. Histology sections were graded using Mankin scores. The correlation between imaging parameters, biochemical contents and histological scores were studied.

Results

Both mean T and T2 at 54.7° were significantly higher than those measured at 90° and 0°, with T showing less increase compared to T2. R (1/T) values had a significant but moderate correlation with proteoglycan contents (R=.45, P=.002), while R2 (1/T2) was not correlated with proteoglycan. No significant correlation was found between relaxation times (T or T2) and collagen contents. The T values of specimen sections with high Mankin scores were significantly higher than those with low Mankin scores (P<.05).

Conclusions

Quantitative MRI has a great potential to provide noninvasive imaging biomarkers for cartilage degeneration in osteoarthritis.  相似文献   
7.
基于Bézier曲线升阶的思想,构造了带多个形状参数的Bézier曲线,它具有与Bézier曲线相同的性质.在控制顶点不变的情况下,可通过改变多个形状参数的取值调整曲线的形状.n次Bézier曲线是n次带多个形状参数的Bézier曲线的一个特例,多个形状参数可使曲线变化更灵活.  相似文献   
8.
The lower trophic linkages in lake plankton food webs are generally described as relatively simple, even accounting for the additional complexity of potential 'microbial looping'. Crustacean zooplankton are frequently amalgamated into one trophic functional group as grazers of autotrophic production. The carbon stable isotope ratios for separated zooplankton species, particulate organic matter (POM) and phytoplankton from a number of lakes in Finland and the UK were analysed. These revealed greater complexity in trophic interactions than would otherwise be observed if the zooplankton had been represented by a mixed sample. Grazing zooplankton were usually depleted in (13)C relative to the bulk POM on which they might feed, with (13)C deviating by up to 17 per thousand There were no consistent differences between (13)C values for copepods and cladocerans. Predatory cladocerans were generally enriched by greater than 1 per thousand compared to their putative prey. We suggest that care in separating the zooplankton species for stable isotope analysis may expose otherwise undetected sources of carbon and facilitate unravelling trophic links further up the food web. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
9.
Let(X, d, μ) be a metric measure space satisfying both the upper doubling and the geometrically doubling conditions in the sense of Hyt?nen. In this paper, the authors obtain the boundedness of the commutators of θ-type Calderón-Zygmund operators with RBMO functions from L~∞(μ) into RBMO(μ) and from H_(at)~(1,∞)(μ) into L~1(μ), respectively.As a consequence of these results, they establish the L~p(μ) boundedness of the commutators on the non-homogeneous metric spaces.  相似文献   
10.
液相混合铋系超导前驱粉体工艺研究   总被引:1,自引:0,他引:1  
本研究采用溶胶凝胶颗粒包覆技术,将钙铜离子均匀包覆在2212颗粒表面,通过适当的热处理,使包覆层转变为Ca2CuO3 CuO相,同时确保2212相结构稳定,从而获得了均匀混合的装管前驱粉体.详细研究了钙铜溶胶体系的胶凝工艺,2212悬浮体系的稳定性以及Ca2CuO3成相温区等工艺参数,并利用XRD,SEM等分析手段,研究了粉体的粒度分布,形貌,相组成及其均匀性.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号