排序方式: 共有43条查询结果,搜索用时 15 毫秒
1.
2.
Measurements of synchrotron radiation emitted by 30-MeV runaway electrons in the TEXTOR-94 tokamak show that the runaway population decays after switching on neutral beam injection (NBI). The decay starts only with a significant delay, which decreases with increasing NBI heating power. This delay provides direct evidence of the energy dependence of runaway confinement, which is expected if magnetic modes govern the loss of runaways. Application of the theory by Mynick and Strachan [Phys. Fluids 24, 695 (1981)] yields estimates for the "mode width" (delta) of magnetic perturbations: delta<0.5 cm in Ohmic discharges, increasing to delta = 4.4 cm for 0. 6 MW NBI. 相似文献
3.
4.
A comparison of three speech coding strategies using an acoustic model of a cochlear implant 总被引:2,自引:0,他引:2
P J Blamey L F Martin G M Clark 《The Journal of the Acoustical Society of America》1985,77(1):209-217
Three alternative speech coding strategies suitable for use with cochlear implants were compared in a study of three normally hearing subjects using an acoustic model of a multiple-channel cochlear implant. The first strategy (F2) presented the amplitude envelope of the speech and the second formant frequency. The second strategy (F0 F2) included the voice fundamental frequency, and the third strategy (F0 F1 F2) presented the first formant frequency as well. Discourse level testing with the speech tracking method showed a clear superiority of the F0 F1 F2 strategy when the auditory information was used to supplement lipreading. Tracking rates averaged over three subjects for nine 10-min sessions were 40 wpm for F2, 52 wpm for F0 F2, and 66 wpm for F0 F1 F2. Vowel and consonant confusion studies and a test of prosodic information were carried out with auditory information only. The vowel test showed a significant difference between the strategies, but no differences were found for the other tests. It was concluded that the amplitude and duration cues common to all three strategies accounted for the levels of consonant and prosodic information received by the subjects, while the different tracking rates were a consequence of the better vowel recognition and the more natural quality of the F0 F1 F2 strategy. 相似文献
5.
Summary Ho in Au exhibits interesting paramagnetism. The full J=8 angular momentum is partially quenched by the crystal field. At sufficiently low temperatures, however, the ion acts like a Van Vleck paramagnet although it has a non-magnetic doublet at ground state instead of a singlet ground state. An applied magnetic field definitely is enhanced by the large hyperfine interaction and excited ground state mixing. This results in anisotropy all the way up to 1 K which makes166m HoAu an excellent candidate for a secondary thermometer in the 10mK-1 K region. The complete interpretation of the166m Ho3+
Au experiments will require sizeable computing times. 相似文献
6.
Speech processing studies using an acoustic model of a multiple-channel cochlear implant 总被引:1,自引:0,他引:1
P J Blamey R C Dowell Y C Tong A M Brown S M Luscombe G M Clark 《The Journal of the Acoustical Society of America》1984,76(1):104-110
The speech perception of two multiple-channel cochlear implant patients was compared with that of three normally hearing listeners using an acoustic model of the implant for 22 different speech tests. The tests used included a minimal auditory capabilities battery, both closed-set and open-set word and sentence tests, speech tracking and a 12-consonant confusion study using nonsense syllables. The acoustic model represented electrical current pulses by bursts of noise and the effects of different electrodes were represented by using bandpass filters with different center frequencies. All subjects used a speech processor that coded the fundamental voicing frequency of speech as a pulse rate and the second formant frequency of speech as the electrode position in the cochlea, or the center frequency of the bandpass filter. Very good agreement was found for the two groups of subjects, indicating that the acoustic model is a useful tool for the development and evaluation of alternative cochlear implant speech processing strategies. 相似文献
7.
Frequency domain (FD) fluorescence lifetime data was collected for a series of 20 crude petroleum oils using a 405 nm excitation
source and over a spectral range of ~426 to ~650 nm. Average fluorescence lifetimes were calculated using three different
models: discrete multi-exponential, Gaussian distribution, and Lorentzian distribution. Fitting the data to extract accurate
average lifetimes using the various models proved easier and less time consuming for the FD data than with Time Correlated
Single Photon Counting (TCSPC) methods however the analysis of confidence intervals to the computed average lifetimes proved
cumbersome for both methods. The uncertainty in the average lifetime was generally larger for the discrete lifetime multi-exponential
model when compared to the distribution-based models. For the lifetime distributions, the data from the light crude oils with
long lifetimes generally fit to a single decay term. Heavier oils with shorter lifetimes required multiple decay terms. The
actual value for the average lifetime is more dependant on the specific fitting model employed than the data acquisition method
used. Correlations between average fluorescence lifetimes and physical and chemical parameters of the crude oils were made
with a view to developing a quantitative model for predicting the gross chemical composition of crude oils. It was found that
there was no significant benefit gained by using FD over TCSPC other than more rapid data analysis in the FD case. For the
FD data the Gaussian distribution model for fluorescence lifetime gave the best correlations with chemical composition allowing
a qualitative correlation to some bulk oil parameters.
相似文献
Alan G. RyderEmail: |
8.
P A Busby Y C Tong S A Roberts P M Altidis S J Dettman P J Blamey G M Clark R K Watson R C Dowell F W Rickards 《The Journal of the Acoustical Society of America》1989,86(6):2088-2102
Assessments in speech perception, speech production, and language skills were conducted on two children, 5 and 10 years old at the time of surgery, using the Nucleus multiple-electrode cochlear implant. Data were collected pre- and post-operatively to measure changes in performance over time. For closed-set speech perception tests in the audition alone condition, post-operative performance was generally better than pre-operative performance and performance improved post-operatively for both patients. In closed-set vowel and consonant identification and open-set sentence perception for the older patient, post-operative improvements from the vision alone to the auditory-visual condition were recorded and performance improved post-operatively in both conditions. In all measures of speech production for both patients, post-operative scores were higher than pre-operative scores and performance improved post-operatively. In language skills, post-operative scores were higher than pre-operative scores and scores improved post-operatively in all measures for both patients. 相似文献
9.
P J Blamey R C Dowell A M Brown G M Clark P M Seligman 《The Journal of the Acoustical Society of America》1987,82(1):48-57
Vowel and consonant confusion matrices were collected in the hearing alone (H), lipreading alone (L), and hearing plus lipreading (HL) conditions for 28 patients participating in the clinical trial of the multiple-channel cochlear implant. All patients were profound-to-totally deaf and "hearing" refers to the presentation of auditory information via the implant. The average scores were 49% for vowels and 37% for consonants in the H condition and the HL scores were significantly higher than the L scores. Information transmission and multidimensional scaling analyses showed that different speech features were conveyed at different levels in the H and L conditions. In the HL condition, the visual and auditory signals provided independent information sources for each feature. For vowels, the auditory signal was the major source of duration information, while the visual signal was the major source of first and second formant frequency information. The implant provided information about the amplitude envelope of the speech and the estimated frequency of the main spectral peak between 800 and 4000 Hz, which was useful for consonant recognition. A speech processor that coded the estimated frequency and amplitude of an additional peak between 300 and 1000 Hz was shown to increase the vowel and consonant recognition in the H condition by improving the transmission of first formant and voicing information. 相似文献
10.