首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   39篇
  免费   1篇
化学   32篇
力学   1篇
物理学   7篇
  2022年   1篇
  2021年   2篇
  2020年   2篇
  2019年   1篇
  2018年   1篇
  2016年   5篇
  2015年   1篇
  2014年   3篇
  2013年   10篇
  2010年   1篇
  2009年   1篇
  2008年   1篇
  2007年   2篇
  2006年   3篇
  2005年   1篇
  2004年   1篇
  2003年   1篇
  2002年   3篇
排序方式: 共有40条查询结果,搜索用时 34 毫秒
1.
In this study, nano hydroxyapatite doped with yttrium (2.5, 5, and 7.5 mol%) and fluoride (2.5 mol%) ions were synthesized by precipitation method and sintered at 900°C, 1100°C, and 1300°C. Raman spectroscopy was applied to track the structural modifications in pure and doped hydroxyapatites. The results showed that the main characteristic band of pure hydroxyapatite at 963 cm?1 was not affected significantly by ion doping but exhibited higher intensity with increasing sintering temperature. Due to fluoride substitution, the 1048 and 1034 cm?1 bands of pure hydroxyapatites appeared with a wavenumber shift in the spectra of ion-doped hydroxyapatites. The 333 cm?1 band of pure hydroxyapatite disappeared and an additional calcium–fluor bond at 322 cm?1 was observable in ion-doped hydroxyapatites. Two fluorescence bands at 770 and 697 cm?1, which were also observed in the spectra of pure hydroxyapatites, shifted to higher wavenumbers in the spectra of ion-doped hydroxyapatites. This was considered to result from the perturbation in the hexagonal structure of hydroxyapatite due to yttrium and fluoride codoping.  相似文献   
2.
Kurbanoglu  Sevinc  Gumustas  Mehmet  Uslu  Bengi  Ozkan  Sibel A. 《Chromatographia》2013,76(21):1477-1485

A RP-LC method is presented, which is sensitive and selective for the simultaneous determination of enalapril–lercanidipine and enalapril–nitrendipine binary mixtures in their pharmaceutical dosage forms. The analyte peaks were detected using the LC method with the mobile phase ratio of methanol: water (70:30 v/v, pH 3.0) and a 1.0 mL min−1 flow rate. The detection wavelength was selected at 210 nm using photo diode array detector and column temperature was optimized to 30 °C. Linearity was obtained at different concentration ranges for all working pharmaceutically active compounds between 0.5 and 25 μg mL−1. The proposed methods were extensively validated according to USP 27 requirements and ICH guidelines. The methods were applied to the analysis of pharmaceutical dosage forms containing binary mixtures of enalapril–lercanidipine and enalapril–nitrendipine. Moreover, the proposed methods were applied for the degradation studies of the selected compounds. Degradation studies were conducted using stress conditions such as UV light, acidic and alkaline hydrolysis, oxidation and heat in oven, to evaluate the ability of the separation of the response of standard compounds from their degradation products.

  相似文献   
3.
This study developed a nanosensor for the detection and determination of favipiravir, a presumed drug that has potential therapeutic efficacy in treating COVID-19 patients, from tablets and serum samples. This nanosensor was obtained by adding the optimum amount of diamond nanoparticles into carbon paste. For the determination of favipiravir adsorptive stripping differential pulse (AdSDPV) and adsorptive stripping square wave voltammetry (AdSSWV) were used. Limit of detection values were found as 4.83×10−9 M and 2.44×10−7 M for bulk and 5.18×10−8 M and 4.38×10−8 M for serum samples using AdSDPV and AdSSWV, respectively. Recovery studies made of the tablet and serum produced satisfactory results.  相似文献   
4.
This paper demonstrates a Schiff base i. e. 5-(diethylamino)-2-((2,6-diethylphenylimino)methyl)phenol (5-DDMP) that was sensed by DNA biosensor. dsDNA was immobilized onto GCE modified with functionalized multi-walled carbon nanotubes to prepare a biosensor. The efficiency of dsDNA biosensor was determined and binding of 5-DDMP with dsDNA was searched by UV-vis spectrophotometry and differential pulse voltammetry. Molecular docking simulations between 5-DDMP and dsDNA were explored and as a result, a hydrogen bond and a π-π contact were observed between 5-DDMP and deoxyguanosine base (dG22) of the strand B, deoxyadenosine base (dA5) of the strand A, respectively. These studies could be useful for new anticancer drug design and development.  相似文献   
5.
Dilek Kul  Bengi Uslu 《Talanta》2010,82(1):286-630
Ziprasidone is a psychotropic agent used for the treatment of schizophrenia. Its oxidation was investigated electrochemically at boron-doped diamond and glassy carbon electrodes using cyclic, differential pulse, and square wave voltammetry. The dependence of the peak current and peak potentials on pH, concentration, nature of the buffer, and scan rate were examined. The process was diffusion and adsorption controlled for boron-doped diamond and glassy carbon electrodes, respectively. The possible mechanism of oxidation was discussed with some model compounds that have indole and piperazine oxidations. A linear response was obtained between 8 × 10−7 and 8 × 10−5 M for the first peak in acetate buffer (pH 5.5) and between 2 × 10−6 and 2 × 10−4 M for the second peak in 0.1 M H2SO4 with boron-doped diamond electrode for differential pulse and square wave voltammetric techniques. The reproducibility and accuracy of the proposed methods were found between 0.31 and 1.20, 99.27 and 100.22, respectively. The recovery studies were also achieved to check selectivity and accuracy of the methods. The proposed methods were applied for the determination of ziprasidone from pharmaceutical dosage forms and human serum samples without any time-consuming extraction, separation, evaporation or adsorption steps prior to drug assay except precipitation of the proteins using acetonitrile. The results were statistically compared with those obtained through an established LC-UV technique, no significant differences were been found between the voltammetric and LC methods.  相似文献   
6.
The temperature dependence of capacitance–voltage (CV) and conductance–voltage (G/wV) characteristics of Al/HfO2/p-Si metal-oxide-semiconductor (MOS) device has been investigated by considering the effect of series resistance (Rs) and interface state density (Nss) over the temperature range of 300–400 K. The CV and G/wV characteristics confirm that the Nss and Rs of the diode are important parameters that strongly influence the electric parameters in MOS device. It is found that in the presence of series resistance, the forward bias CV plots exhibits a peak, and its position shifts towards lower voltages with increasing temperature. The density of Nss, depending on the temperature, was determined from the (CV) and (G/wV) data using the Hill–Coleman Method. Also, the temperature dependence of dielectric properties at different fixed frequencies over the temperature range of 300–400 K was investigated. In addition, the electric modulus formalisms were employed to understand the relaxation mechanism of the Al/HfO2/p-Si structure.  相似文献   
7.
Uslu B  Topal BD  Ozkan SA 《Talanta》2008,74(5):1191-1200
The anodic behavior and determination of pefloxacin on boron-doped diamond and glassy carbon electrodes were investigated using cyclic, linear sweep, differential pulse and square wave voltammetric techniques. In cyclic voltammetry, pefloxacin shows one main irreversible oxidation peak and additional one irreversible ill-defined wave depending on pH values for both electrodes. The results indicate that the process of pefloxacin is irreversible and diffusion controlled on boron-doped diamond electrode and irreversible but adsorption controlled on glassy carbon electrode. The peak current is found to be linear over the range of concentration 2 × 10−6 to 2 × 10−4 M in 0.5 M H2SO4 at about +1.20 V (versus Ag/AgCl) for differential pulse and square wave voltammetric technique using boron-doped diamond electrode. The repeatability, reproducibility, precision and accuracy of the methods in all media were investigated. Selectivity, precision and accuracy of the developed methods were also checked by recovery studies. The procedures were successfully applied to the determination of the drug in pharmaceutical dosage forms and humans serum samples with good recovery results. No electroactive interferences from the excipients and endogenous substances were found in the pharmaceutical dosage forms and biological samples, respectively.  相似文献   
8.
Voltammetric and liquid chromatographic (LC) methods have been developed for the simultaneous determination of amlodipine besylate (AML) and rosuvastatin calcium (ROS) for the first time. Detailed electrochemical behavior and simultaneous voltammetric determination of AML and ROS were investigated in detail using glassy carbon electrode (GCE). High-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC) were also developed for the comparison. Voltammetric method exhibited linear dynamic responses for the simultaneous assay of AML and ROS in the concentration range between 0.006 and 2.85 μg/mL and between 0.01 and 5.00 μg/mL, with detection limits of 0.001 and 0.003 μg/mL, respectively. On the other hand, LC methods presented a wider linearity range than that of the SWV method between 0.5 and 100 μg/mL with the detection limits of 0.011 and 0.027 μg/mL for AML and 0.034 and 0.042 μg/mL for ROS by UPLC and HPLC techniques, respectively.  相似文献   
9.
The effect of surface modifications on the electrochemical behavior of the anticancer drug idarubicin was studied at multiwalled carbon nanotubes modified glassy carbon and edge plane pyrolytic graphite electrodes. The surface morphology of the modified electrodes was characterized by scanning electron microscopy. The modified electrodes were constructed for the determination of idarubicin using adsorptive stripping differential pulse voltammetry. The experimental parameters such as supporting electrolyte, pH, accumulation time and potential, amount of carbon nanotubes for the sensitive assay of idarubicin were studied as details. Under the optimized conditions, idarubicin gave a linear response in the range 9.36×10?8–1.87×10?6 M for modified glassy carbon and 9.36×10?8–9.36×10?7 M for modified edge plane pyrolytic graphite electrodes. The detection limits were found as 1.87×10?8 M and 3.75×10?8 M based on modified glassy carbon and edge plane pyrolytic graphite electrodes, respectively. Interfering species such as ascorbic acid, dopamine, and aspirin showed no interference with the selective determination of idarubicin. The analyzing method was fully validated and successfully applied for the determination of idarubicin in its pharmaceutical dosage form. The possible oxidation mechanism of idarubicin was also discussed. The results revealed that the modified electrodes showed an obvious electrocatalytic activity toward the oxidation of idarubicin by a remarkable enhancement in the current response compared with bare electrodes.  相似文献   
10.
A sensitive and selective electroanalytical method for the determination of tadalafil (TAD) using adsorptive stripping square wave voltammetry at multiwalled carbon nanotube paste electrode (MWCNTPE) and modified TiO2-multiwalled carbon nanotube paste electrode (TiO2-MWCNTPE) was presented. The calibration curves were linear in the concentration range of 3.6–8.1 and 12.7–61.1 μM on MWCNTPE, 0.27–15.2 μM on TiO2-MWCNTPE. The recommended method was successfully applied to the determination of the drug in tablets and human serum samples with good recoveries. The selectivity of the proposed method was considered in the presence of Ca2+, K+, Na+, 2-mercapto benzimidazole, thiourea, and dopamine by means of recovery tests. Interfering agents did not show considerable effect on TAD determination. No electroactive interferences from the tablet excipients and endogenous substances from biological material were detected. The possible electrooxidation pathway and the number of transferred electrons were also investigated.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号