首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   30篇
  免费   1篇
  国内免费   7篇
化学   29篇
力学   1篇
数学   1篇
物理学   7篇
  2021年   1篇
  2019年   1篇
  2018年   2篇
  2017年   1篇
  2016年   3篇
  2013年   4篇
  2011年   2篇
  2009年   5篇
  2008年   3篇
  2005年   1篇
  2004年   1篇
  2000年   3篇
  1999年   1篇
  1998年   1篇
  1997年   3篇
  1995年   1篇
  1994年   1篇
  1990年   2篇
  1986年   1篇
  1908年   1篇
排序方式: 共有38条查询结果,搜索用时 15 毫秒
1.
A fast digital oscilloscope based pulse shape discrimination (PSD) system has been tested with intrinsic germanium detectors large enough to allow ionizing events which generate localized electron-hole pairs at a single site to be segregated from those depositing energy at several different sites in the crystal. Drift velocities of the electrons and holes result in pulses several hundred nanoseconds long. Since the electric field varies by almost a factor of 10 between the outer and inner surfaces, collection of electrons and holes can frequently be dinstinguished, and pulses due to multi-site events can be distinguished from single site events.  相似文献   
2.
本文研究以非离子型表面活性剂-正辛醇-水-芳烃类所组成的微乳液, 探讨醇从油相转移到界面相时的自由能变化, 以及温度对自由能的影响。计算出熵和焓的变化, 发现在实验范围内, 上述热力学函数的对数值与芳烃侧链的碳原子数(n)呈线性关系。这些关系式对微乳液的构成和稳定性的讨论是重要的, 还对几种芳烃异构体所构成的微乳液的热力学函数进行了实验和讨论。  相似文献   
3.
4.
The Pacific Northwest National Laboratory (PNNL) is currently developing a custom software suite capable of automating many of the tasks required to accurately analyze coincident signals within gamma spectrometer arrays. During the course of this work, significant crosstalk was identified in the energy determination for spectra collected with a new low-background intrinsic germanium (HPGe) array at PNNL. The HPGe array is designed for high detection efficiency, ultra-low-background performance, and sensitive γ–γ coincidence detection. The first half of the array, a single cryostat containing seven HPGe crystals, was recently installed into a new shallow underground laboratory facility. This update will present a brief review of the germanium array, describe the observed crosstalk, and present a straight-forward empirical correction that significantly reduces the impact of this crosstalk on the spectroscopic performance of the system.  相似文献   
5.
6.
C70X2(X=H,F, Cl)的稳定性和电子光谱   总被引:1,自引:0,他引:1  
滕启文  吴师  郝策  赵学庄  唐敖庆  封继康 《化学学报》1997,55(11):1072-1076
用INDO方法研究C70H2四种异构体的稳定性, 表明其最稳定异构体为1, 9-C70H2和7, 8-C70H2, 两者能量差为16.3KJ.mol^-^1, 与实验值及ab initio计算值接近; 光谱计算表明, 其特征吸收峰与实验值一致。在此基础上预测C70F2和C70Cl2的稳定性和电子光谱, 表明C70F2四种异构体的稳定性顺序与C70H2一致, 而C70Cl2则以21, 42-异构体最为稳定。二者的电子光谱与C70H2极其相似只是在500nm以上有细微差别。  相似文献   
7.
本文用对势方法研究了氢原子在Ni(510)台阶面上的吸附和振动, 计算结果与实验符合得很好。并考察了氢原子在Ni(997)台阶面上的吸附和扩散, 结果表明,台阶对下台面上扩散的氢原子开成捕获势阱, 对上台面扩散的氢原子形成反射势,这也很好地支持了实验结果。  相似文献   
8.
Aerosol samples collected on filter media were analyzed using HPGe detectors employing varying background-reduction techniques in order to experimentally evaluate the opportunity to apply ultra-low background measurement methods to samples collected, for instance, by the Comprehensive Test Ban Treaty International Monitoring System (IMS). In this way, realistic estimates of the impact of low-background methodology on the sensitivity obtained in systems such as the IMS were assessed. The current detectability requirement of stations in the IMS is 30 μBq/m3 of air for 140Ba, which would imply ~106 fissions per daily sample. Importantly, this is for a fresh aerosol filter. One week of decay reduces the intrinsic background from radon daughters in the sample allowing much higher sensitivity measurement of relevant isotopes, including 131I. An experiment was conducted in which decayed filter samples were measured at a variety of underground locations using Ultra-Low Background (ULB) gamma spectroscopy technology. The impacts of the decay and ULB are discussed.  相似文献   
9.
Physics experiments, environmental surveillance, and treaty verification techniques continue to require increased sensitivity for detecting and quantifying radionuclides of interest. This can be done by detecting a greater fraction of gamma emissions from a sample (higher detection efficiency) and reducing instrument backgrounds. A current effort for increased sensitivity in high resolution gamma spectroscopy will produce an intrinsic germanium (HPGe) array designed for high detection efficiency, ultra-low-background performance, and useful coincidence efficiencies. The system design is optimized to accommodate filter paper samples, e.g. samples collected by the Radionuclide Aerosol Sampler/Analyzer (RASA). The system will provide high sensitivity for weak collections on atmospheric filter samples, as well as offering the potential to gather additional information from more active filters using gamma cascade coincidence detection. The current effort is constructing an ultra-low-background HPGe crystal array consisting of two vacuum cryostats, each housing a hexagonal array of 7 crystals on the order of 70% relative efficiency per crystal. Traditional methods for constructing ultra-low-background detectors are used, including use of materials known to be low in radioactive contaminants, use of ultra pure reagents, clean room assembly, etc. The cryostat will be constructed mainly from copper electroformed into near-final geometry at PNNL. Details of the detector design, simulation of efficiency and coincidence performance, HPGe crystal testing, and progress on cryostat construction are presented.  相似文献   
10.
制备了甘氨酸-壳聚糖复合膜修饰玻碳电极(Gly-CTS/GCE),研究了抗坏血酸(AA)和尿酸(UA)在该修饰电极上的电化学行为。结果表明在pH=5.59的磷酸盐缓冲溶液中,AA、UA在Gly-CTS/GCE上均产生灵敏的不可逆氧化峰,其峰电流与浓度在一定范围内呈良好的线性关系。对AA和UA混合溶液平行测定7次,相对标准偏差分别为4.6%、2.9%,表明该电极重现性和稳定性良好。AA、UA在Gly-CTS/GCE电极上的氧化峰峰电位相差340mV,据此可实现对二者的同时检测,并可应用于实际样品测定。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号