排序方式: 共有27条查询结果,搜索用时 15 毫秒
1.
尚雷蔡啸 王曼王志刚 方建刘春秀 刘万金孙丽君李光毅 严亮张宏杰 张振华单利民周莉 俞伯祥袁诚赵正印 秦纲夏小米 赖元芬董明义 谢文杰胡涛 吕军光 《中国物理 C》2007,31(2):177-182
利用宇宙射线进行探测器模型的性能测试是高能物理普遍采用的方法,其中最重要的步骤之一就是确定宇宙线入射的准确位置和径迹.多数采用丝室探测器来进行宇宙线的精确定位,需要很高的造价和复杂的电子学系统.本文介绍一种简单的定位方法,采用塑料闪烁体条加波移剂光纤编码读出的方式,可以实现精度为1cm的定位.据此建立了一套实验装置,对BESⅢ电磁量能器CsⅠ(Tl)晶体探测器单元的光输出强度和不均匀性进行了测量. 相似文献
2.
吕绮雯 郑阳恒 田彩星 刘福虎 蔡啸 方建 高龙 葛永帅 刘颖彪 孙丽君 孙希磊 牛顺利 王志刚 谢宇广 薛镇 俞伯祥 章爱武 胡涛 吕军光 《物理学报》2012,61(7):72904-072904
本研究采用双层150 mm×150 mm闪烁条阵列定位宇宙线的入射和出射位置. 阵列信号光使用波移光纤吸收传输,在ICCD相机前插入前置像增强器,使信号光延迟大于200 ns, 使ICCD可以由外部高速触发信号控制,有效记录随机触发事例.该宇宙线定位系统可以同时多点密集测量 通用探测器测试平台的时间分辨和闪烁光的渡越时间.该新方法与传统时间分辨测量方法相比提高了30倍以上 的效率.实验结果显示:时间探测器的时间分辨好于200 ps,满足通用探测器测试平台的设计要求. 相似文献
3.
莫晓虎 张建勇 张清江 Achasov Mikhail 蔡啸 傅成栋 Harris Fred 刘倩 Muchnoi Nikolay 秦庆 屈化民 王贻芳 徐金强 张天保 《中国物理 C》2011,35(7):642-655
Understanding the radiation background at the north crossing point (NCP) in the tunnel of BEPCII is crucial for the performance safety of the High Purity Germanium (HPGe) detector, and in turn of great significance for long-term stable running of the energy measurement system. Therefore, as the first step, a NaI(Tl) detector is constructed to continuously measure the radiation level of photons as background for future experiments. Furthermore, gamma and neutron dosimeters are utilized to explore the radiation distribution in the vicinity of the NCP where the HPGe detector will be located. Synthesizing all obtained information, the shielding for neutron irradiation is studied based on model-dependent theoretical analysis. 相似文献
4.
A novel 2-dimensional cosmic ray position detector based on a CsI(Na) pixel array and an ICCD camera
A novel 2-D cosmic ray position detector has been built and studied. It is integrated from a CsI(Na) crystal pixel array, an optical fiber array, an image intensifier and an ICCD camera. The 2-D positions of one cosmic ray track is determined by the location of a fired CsI(Na) pixel. The scintillation light of these 1.0× 1.0 mm CsI(Na) pixels is delivered to the image intensifier through fibers. The light information is recorded in the ICCD camera in the form of images, from which the 2-D positions can be reconstructed. The background noise and cosmic ray images have been studied. The study shows that the cosmic ray detection efficiency can reach up to 11.4%, while the false accept rate is less than 1%. 相似文献
5.
The fast luminosity monitor counting the γ photons above a given energy threshold emitted from radiative Bhabha scattering has been operated in the BEPC Ⅱ to measure the relative luminosity bunch by bunch for the first time and used successfully in beam tuning of BEPC Ⅱ. In the relative mode the monitor is able to deliver the relative luminosities with an accuracy of 0.8 %. By steering the electron beam while observing the counting rate changes of the monitor the horizontal and vertical sizes of the bunch spots can be estimated as: Sxe+ =Sxe =0.356 mm, Sye+ =Sye- =0.011 mm. 相似文献
6.
7.
THGEMs based on a ceramic substrate have been successfully developed for neutron and single photon detection. The influences on thermal neutron scattering and internal radioactivity of both ceramic and FR-4 substrates were studied and compared. The ceramic THGEMs are homemade, of 200 μm hole diameter, 600 μm pitch, 200 μm thickness, 80 μm rim, and 50 mm×50 mm sensitive area. FR-4 THGEMs with the same geometry were used as a reference. The gas gain, energy resolution and gain stability were measured in different gas mixtures using 5.9 keV X-rays. The maximum gain of a single layer ceramic THGEM reaches 6×104 and 1.5×104 at Ne+CH4=95:5 and Ar+i-C4H10=97:3, respectively. The energy resolution is better than 24%. Good gain stability was obtained during a more than 100 hour continuous test in Ar+CO2=80:20. By using a 239Pu source, the alpha deposited energy spectrum and gain curve of the ceramic THGEM were measured. 相似文献
8.
An attenuation length measurement device was constructed using an oscilloscope and LabVIEW for signal acquisition and processing. The performance of the device has been tested in a variety of ways. The test results show that the set-up has a good stability and high precision (sigma/mean reached 0.4 percent). Besides, the accuracy of the measurement system will decrease by about 17 percent if a filter is used. The attenuation length of a gadolinium-loaded liquid scintillator (Gd-LS) was measured as 15.10±0.35 m where Gd-LS was heavily used in the Daya Bay Neutrino Experiment. In addition, one method based on the Beer-Lambert law was proposed to investigate the reliability of the measurement device, the R-square reached 0.9995. Moreover, three purification methods for Linear Alkyl Benzene (LAB) production were compared in the experiment. 相似文献
9.
The CsI(Tl) crystal modules of the Beijing Spectrometer Ⅲ (BESⅢ) electro-magnetic calorimeter (EMC) were designed and assembled through Monte Carlo simulation and experiments. After the assembly was finished, the performance of each crystal module was tested by cosmic rays. All crystal modules were found to work well before the installation of EMC. 相似文献
10.