排序方式: 共有15条查询结果,搜索用时 15 毫秒
1.
设计了一种基于光纤马赫曾德尔干涉仪的优化双凹锥结构。该结构通过单模光纤和保偏光纤之间使用不充分的电弧放电熔接制作而成,可以实现应变和温度的同步测量.凹锥中部的球形纤芯可以进一步地调控包层和纤芯中的光能量分布,经优化几何参数后的结构可以获得16 dB的干涉条纹消光比,大于相同参数下的双凹锥结构。传感实验表明所提出的结构在0~244.35με和25~50℃的范围内分别具有±1.616με和±0.79°C的高分辨率。由于交叉敏感导致两个参数的测量误差均小于1×10~(-3)%.这种结构为同时测量应变和温度提供了一种有效的方法,可应用于精密仪器测量中. 相似文献
2.
3.
Hybrid Optoelectronic Bistability in Frequency-Domain and Its Potential Application in FBG Sensors 下载免费PDF全文
We propose a novel optical bistable device (OBD) in frequency-domain with which we can perform optical bistable operations in a number of fibre Bragg gratings (FBGs) which are included in the same OBD. Such an OBD may bring more opportunities in applications and, as an example, we show the possibility of using it in an FBG sensor demodulating system. By use of a tunable light source, consisting of a broad band source and a scanning fibre F-P (FFP), we demonstrate the above-mentioned operations experimentally. 相似文献
4.
5.
提出了一种正弦调制多光束激光外差二次谐波测量微冲量的新方法,将激光与工质靶作用产生的微冲量转化为扭摆的转动角度测量,基于激光外差技术和多普勒效应,把待测转角信息加载到外差信号的频率差中,经信号解调后可以得到待测转角值,通过多次测量取平均值的方法可以提高待测转角的测量精度,从而提高微冲量的测量精度。利用这种新方法,以PVC+2%C为工质靶,利用MATLAB仿真测量了激光与工质靶作用产生的微冲量,结果表明:该测量的最大相对误差小于0.8%。 相似文献
6.
基于小尺寸缓存的提前预留机制是有效的竞争解决方案.为支持区分服务,本文研究了两优先级提前预留机制的阻塞模型,分析了变化缓存尺寸与载荷比率条件下光突发交换网络核心节点的阻塞性能.为降低两优先级提前预留机制的突发丢弃率,提出一种基于流量门限的提前预留机制.数值分析确定了合理的缓存尺寸与流量门限,实现了高、低优先级间的缓存使用平衡.仿真结果表明:与原有提前预留机制相比,基于流量门限的提前预留机制保持了全流量状态范围内的阻塞性能,并明显降低了中、低流量状态内的突发丢弃率. 相似文献
7.
8.
9.
Low-cost,high performance surface plasmon resonance-compatible films characterized by the surface plasmon resonance technique 下载免费PDF全文
A new analytical method based on the surface plasmon resonance (SPR) technique is presented, with which SPR curves for both wavelength and angular modulations can be obtained simultaneously via only a single scan of the incident angle. Using this method, the SPR responses of TiO2-coated Cu films are characterized in the wavelength range from 600 nm to 900 nm. For the first time, we determine the effective optical constants and the thicknesses of TiO2-coated Cu films using the SPR curves of wavelength modulation. The sensitivities of prism-based SPR refractive index sensors using TiO2-coated Cu films are investigated theoretically for both wavelength and angular modulations, the results show that in the case of sensitivity with wavelength modulation, TiO2-coated Cu films are not as good as the Au film, however, they are more suitable than the Au film for SPR refractive index sensors with angular modulation because a higher sensitivity can be achieved. 相似文献
10.
提出了一种正弦调制多光束激光外差二次谐波测量微冲量的新方法,将激光与工质靶作用产生的微冲量转化为扭摆的转动角度测量,基于激光外差技术和多普勒效应,把待测转角信息加载到外差信号的频率差中,经信号解调后可以得到待测转角值,通过多次测量取平均值的方法可以提高待测转角的测量精度,从而提高微冲量的测量精度。利用这种新方法,以PVC+2%C为工质靶,利用MATLAB仿真测量了激光与工质靶作用产生的微冲量,结果表明:该测量的最大相对误差小于0.8%。 相似文献